RSS James Clark Ross Cruise JR20120601/JR272 CTD Data Quality Document
Downwelling PAR Irradiance (DWIRPP01)
PAR data were from the stainless steel CTD casts only. This was because the PAR sensors were not always installed on the titanium casts, as the majority of deployments were deeper than 500 metres.
Attenuance (ATTNDR01) and Transmittance (POPTDR01)
For many of the casts, the attenuance values produced by the manufacturer's calibration were negative and outside the expected range of the parameter (0 to 400 m-1). All negative values were flagged. Although the actual values may be considered suspect, the shape of the profiles appears reasonable and the user may wish to determine an appropriate offset for the values from the cruise to correct the values to bring them within the expected range for attenuance values.
As with the attenuance profiles the values in the transmittance channel go beyond 100 % transmittance. Occurrences of this have been flagged as suspect. The transmittance channels are only available from the titanium CTD casts. The stainless steel casts do not have transmittance channels.
Fluorescence (CPHLPM01)
Some of the casts have data values that are outside of the parameter range (0 to 999 mg m3) that have been flagged as suspect. Several of the profiles have some spikes that have been flagged as suspect. Cast CTD004s is constant with values of zero.
Data Access Policy
Open Data
These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.
If the Information Provider does not provide a specific attribution statement, or if you are using Information from several Information Providers and multiple attributions are not practical in your product or application, you may consider using the following:
"Contains public sector information licensed under the Open Government Licence v1.0."
Narrative Documents
Sea-Bird Dissolved Oxygen Sensor SBE 43 and SBE 43F
The SBE 43 is a dissolved oxygen sensor designed for marine applications. It incorporates a high-performance Clark polarographic membrane with a pump that continuously plumbs water through it, preventing algal growth and the development of anoxic conditions when the sensor is taking measurements.
Two configurations are available: SBE 43 produces a voltage output and can be incorporated with any Sea-Bird CTD that accepts input from a 0-5 volt auxiliary sensor, while the SBE 43F produces a frequency output and can be integrated with an SBE 52-MP (Moored Profiler CTD) or used for OEM applications. The specifications below are common to both.
Specifications
Housing | Plastic or titanium |
Membrane | 0.5 mil- fast response, typical for profile applications 1 mil- slower response, typical for moored applications |
Depth rating | 600 m (plastic) or 7000 m (titanium) 10500 m titanium housing available on request |
Measurement range | 120% of surface saturation |
Initial accuracy | 2% of saturation |
Typical stability | 0.5% per 1000 h |
Further details can be found in the manufacturer's specification sheet.
Instrument Description JR20120601 Stainless Steel Frame
Standard Rosette CTD Unit and Auxiliary Sensors
Two CTD systems were used during this cruise; a stainless steel frame and a titanium frame. This document outlines the instrument description of the first water sampling arrangement of the stainless steel frame.
A 24-way stainless steel frame (s/n SBE CTD1), with a Sea-Bird 9/11 plus underwater unit (SN 09P-15759-0480) with secondary temperature and conductivity sensors was used throughout the cruise. All other instruments were attached to a Sea-Bird 32 Carousel 24 Position Pylon (s/n 32-46833-0636) with Ocean Test Equipment 20L ES-120B water samples (s/n 1A -12A, 15A-21A, 24A, 26A, 34A, 45A, 47A).
The CTD unit included the following sensors
Sensor | Model | Serial Number | Calibration | Comments |
---|---|---|---|---|
Pressure transducer | Digiquartz temperature compensated pressure sensor, Frequency 2 | 106017 | 11/05/2011 | - |
Conductivity sensor | SBE 4C, Frequency 1 | 04C-4087 | 19/04/2012 | Primary sensor |
Conductivity sensor | SBE 4C, Frequency 4 | 04C-4126 | 13/04/2012 | Secondary sensor |
Temperature sensor | SBE 3P, Frequency 0 | 03P-5645 | 12/04/2012 | Primary sensor |
Temperature sensor | SBE 3P, Frequency 3 | 03P-5623 | 13/04/2012 | Secondary sensor |
Dissolved oxygen | SBE 43 | 43-2290 | 31/03/2012 | - |
Fluorometer | Chelsea MKIII Aquatracka fluorometer | 088-249 | 09/11/2009 | - |
Transmissometer | WETLabs C-Star 25cm path transmissometer | CST-1497DR | 28/12/2011 | - |
Photosynthetically Active Radiation | Biospherical QCD-905L PAR irradiance sensor, DWIRR | 7235 | 12/07/2010 | - |
Altimeter | Tritech PA200 altimeter | 244738 | 10/05/2012 | - |
The Stainless Steel CTD system used an 11 plus deck unit (s/n 11P-20397-0502).
Sea-Bird Electronics SBE 911 and SBE 917 series CTD profilers
The SBE 911 and SBE 917 series of conductivity-temperature-depth (CTD) units are used to collect hydrographic profiles, including temperature, conductivity and pressure as standard. Each profiler consists of an underwater unit and deck unit or SEARAM. Auxiliary sensors, such as fluorometers, dissolved oxygen sensors and transmissometers, and carousel water samplers are commonly added to the underwater unit.
Underwater unit
The CTD underwater unit (SBE 9 or SBE 9 plus) comprises a protective cage (usually with a carousel water sampler), including a main pressure housing containing power supplies, acquisition electronics, telemetry circuitry, and a suite of modular sensors. The original SBE 9 incorporated Sea-Bird's standard modular SBE 3 temperature sensor and SBE 4 conductivity sensor, and a Paroscientific Digiquartz pressure sensor. The conductivity cell was connected to a pump-fed plastic tubing circuit that could include auxiliary sensors. Each SBE 9 unit was custom built to individual specification. The SBE 9 was replaced in 1997 by an off-the-shelf version, termed the SBE 9 plus, that incorporated the SBE 3 plus (or SBE 3P) temperature sensor, SBE 4C conductivity sensor and a Paroscientific Digiquartz pressure sensor. Sensors could be connected to a pump-fed plastic tubing circuit or stand-alone.
Temperature, conductivity and pressure sensors
The conductivity, temperature, and pressure sensors supplied with Sea-Bird CTD systems have outputs in the form of variable frequencies, which are measured using high-speed parallel counters. The resulting count totals are converted to numeric representations of the original frequencies, which bear a direct relationship to temperature, conductivity or pressure. Sampling frequencies for these sensors are typically set at 24 Hz.
The temperature sensing element is a glass-coated thermistor bead, pressure-protected inside a stainless steel tube, while the conductivity sensing element is a cylindrical, flow-through, borosilicate glass cell with three internal platinum electrodes. Thermistor resistance or conductivity cell resistance, respectively, is the controlling element in an optimized Wien Bridge oscillator circuit, which produces a frequency output that can be converted to a temperature or conductivity reading. These sensors are available with depth ratings of 6800 m (aluminium housing) or 10500 m (titanium housing). The Paroscientific Digiquartz pressure sensor comprises a quartz crystal resonator that responds to pressure-induced stress, and temperature is measured for thermal compensation of the calculated pressure.
Additional sensors
Optional sensors for dissolved oxygen, pH, light transmission, fluorescence and others do not require the very high levels of resolution needed in the primary CTD channels, nor do these sensors generally offer variable frequency outputs. Accordingly, signals from the auxiliary sensors are acquired using a conventional voltage-input multiplexed A/D converter (optional). Some Sea-Bird CTDs use a strain gauge pressure sensor (Senso-Metrics) in which case their pressure output data is in the same form as that from the auxiliary sensors as described above.
Deck unit or SEARAM
Each underwater unit is connected to a power supply and data logging system: the SBE 11 (or SBE 11 plus) deck unit allows real-time interfacing between the deck and the underwater unit via a conductive wire, while the submersible SBE 17 (or SBE 17 plus) SEARAM plugs directly into the underwater unit and data are downloaded on recovery of the CTD. The combination of SBE 9 and SBE 17 or SBE 11 are termed SBE 917 or SBE 911, respectively, while the combinations of SBE 9 plus and SBE 17 plus or SBE 11 plus are termed SBE 917 plus or SBE 911 plus.
Specifications
Specifications for the SBE 9 plus underwater unit are listed below:
Parameter | Range | Initial accuracy | Resolution at 24 Hz | Response time |
---|---|---|---|---|
Temperature | -5 to 35°C | 0.001°C | 0.0002°C | 0.065 sec |
Conductivity | 0 to 7 S m-1 | 0.0003 S m-1 | 0.00004 S m-1 | 0.065 sec (pumped) |
Pressure | 0 to full scale (1400, 2000, 4200, 6800 or 10500 m) | 0.015% of full scale | 0.001% of full scale | 0.015 sec |
Further details can be found in the manufacturer's specification sheet.
Chelsea Technologies Group Aquatracka MKIII fluorometer
The Chelsea Technologies Group Aquatracka MKIII is a logarithmic response fluorometer. Filters are available to enable the instrument to measure chlorophyll, rhodamine, fluorescein and turbidity.
It uses a pulsed (5.5 Hz) xenon light source discharging along two signal paths to eliminate variations in the flashlamp intensity. The reference path measures the intensity of the light source whilst the signal path measures the intensity of the light emitted from the specimen under test. The reference signal and the emitted light signals are then applied to a ratiometric circuit. In this circuit, the ratio of returned signal to reference signal is computed and scaled logarithmically to achieve a wide dynamic range. The logarithmic conversion accuracy is maintained at better than one percent of the reading over the full output range of the instrument.
Two variants of the instrument are available, both manufactured in titanium, capable of operating in depths from shallow water down to 2000 m and 6000 m respectively. The optical characteristics of the instrument in its different detection modes are visible below:
Excitation | Chlorophyll a | Rhodamine | Fluorescein | Turbidity |
---|---|---|---|---|
Wavelength (nm) | 430 | 500 | 485 | 440* |
Bandwidth (nm) | 105 | 70 | 22 | 80* |
Emission | Chlorophyll a | Rhodamine | Fluorescein | Turbidity |
Wavelength (nm) | 685 | 590 | 530 | 440* |
Bandwidth (nm) | 30 | 45 | 30 | 80* |
* The wavelengths for the turbidity filters are customer selectable but must be in the range 400 to 700 nm. The same wavelength is used in the excitation path and the emission path.
The instrument measures chlorophyll a, rhodamine and fluorescein with a concentration range of 0.01 µg l-1 to 100 µg l-1. The concentration range for turbidity is 0.01 to 100 FTU (other wavelengths are available on request).
The instrument accuracy is ± 0.02 µg l-1 (or ± 3% of the reading, whichever is greater) for chlorophyll a, rhodamine and fluorescein. The accuracy for turbidity, over a 0 - 10 FTU range, is ± 0.02 FTU (or ± 3% of the reading, whichever is greater).
Further details are available from the Aquatracka MKIII specification sheet.
Biospherical Instruments Log Quantum Cosine Irradiance Sensor QCD-905L
The QCD-905L is a submersible radiometer designed to measure irradiance over Photosynthetically Active Radiation (PAR) wavelengths (400-700 nm). It features a cosine directional response when fully immersed in water.
The sensor is a blue-enhanced high stability silicon photovoltaic detector with dielectric and absorbing glass filter assembly, and produces a logarithmic output. Normal output range is -1 to 6 volts with 1 volt per decade. Typically, the instrument outputs 5 volts for full sunlight and has a minimum output of 0.001% full sunlight, where typical noon solar irradiance is 1.5 to 2 x 1017 quanta cm-2 s-1. The instrument can be calibrated with constants for µE cm-2 s-1 or quanta cm-2 s-1.
The QCD-905L can be coupled to a fixed range data acquisition system like a CTD (Conductivity-Temperature-Depth) profiler or current meter. It has an aluminium and PET housing, and a depth rating of 7000 m.
Specifications
Wavelength | 400 to 700 nm |
Output range | -1 to 6 V, with 1 V decade-1 |
Operating temperature | -2 to 35°C |
Depth range | 0 - 7000 m |
Further details can be found in the manufacturer's manual.
Paroscientific Absolute Pressure Transducers Series 3000 and 4000
Paroscientific Series 3000 and 4000 pressure transducers use a Digiquartz pressure sensor to provide high accuracy and precision data. The sensor comprises a quartz crystal resonator that responds to pressure-induced stress, and temperature is measured for thermal compensation of the calculated pressure.
The 3000 series of transducers includes one model, the 31K-101, whereas the 4000 series includes several models, listed in the table below. All transducers exhibit repeatability of better than ±0.01% full pressure scale, hysteresis of better than ±0.02% full scale and acceleration sensitivity of ±0.008% full scale /g (three axis average). Pressure resolution is better than 0.0001% and accuracy is typically 0.01% over a broad range of temperatures.
Differences between the models lie in their pressure and operating temperature ranges, as detailed below:
Model | Max. pressure (psia) | Max. pressure (MPa) | Temperature range (°C) |
---|---|---|---|
31K-101 | 1000 | 6.9 | -54 to 107 |
42K-101 | 2000 | 13.8 | 0 to 125 |
43K-101 | 3000 | 20.7 | 0 to 125 |
46K-101 | 6000 | 41.4 | 0 to 125 |
410K-101 | 10000 | 68.9 | 0 to 125 |
415K-101 | 15000 | 103 | 0 to 50 |
420K-101 | 20000 | 138 | 0 to 50 |
430K-101 | 30000 | 207 | 0 to 50 |
440K-101 | 40000 | 276 | 0 to 50 |
Further details can be found in the manufacturer's specification sheet.
Project Information
UKOARP Theme B: Ocean acidification impacts on sea surface biology, biogeochemistry and climate
The overall aim of this theme is to obtain a quantitative understanding of the impact of ocean acidification (OA) on the surface ocean biology and ecosystem and on the role of the surface ocean within the overall Earth System.
The aims of the theme are:
- To ascertain the impact of OA on planktonic organisms (in terms of physiological impacts, morphology, population abundances and community composition).
- To quantify the impacts of OA on biogeochemical processes affecting the ocean carbon cycle (both directly and indirectly, such as via availability of bio-limiting nutrients).
- To quantify the impacts of OA on the air-sea flux of climate active gases (DMS and N2O in particular).
The main consortium activities will consist of in-situ measurements on three dedicated cruises, as well as on-deck bioassay experiments probing the response of the in-situ community to elevated CO2. Most of the planned work will be carried out on the three cruises to locations with strong gradients in seawater carbon chemistry and pH; the Arctic Ocean, around the British Isles and the Southern Ocean.
Weblink: http://www.oceanacidification.org.uk/research_programme/surface_ocean.aspx
Data Activity or Cruise Information
Cruise
Cruise Name | JR20120601 (JR271) |
Departure Date | 2012-06-01 |
Arrival Date | 2012-07-02 |
Principal Scientist(s) | Ray Leakey (Scottish Association for Marine Science) |
Ship | RRS James Clark Ross |
Complete Cruise Metadata Report is available here
Fixed Station Information
No Fixed Station Information held for the Series
BODC Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
Blank | Unqualified |
< | Below detection limit |
> | In excess of quoted value |
A | Taxonomic flag for affinis (aff.) |
B | Beginning of CTD Down/Up Cast |
C | Taxonomic flag for confer (cf.) |
D | Thermometric depth |
E | End of CTD Down/Up Cast |
G | Non-taxonomic biological characteristic uncertainty |
H | Extrapolated value |
I | Taxonomic flag for single species (sp.) |
K | Improbable value - unknown quality control source |
L | Improbable value - originator's quality control |
M | Improbable value - BODC quality control |
N | Null value |
O | Improbable value - user quality control |
P | Trace/calm |
Q | Indeterminate |
R | Replacement value |
S | Estimated value |
T | Interpolated value |
U | Uncalibrated |
W | Control value |
X | Excessive difference |
SeaDataNet Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
0 | no quality control |
1 | good value |
2 | probably good value |
3 | probably bad value |
4 | bad value |
5 | changed value |
6 | value below detection |
7 | value in excess |
8 | interpolated value |
9 | missing value |
A | value phenomenon uncertain |
B | nominal value |
Q | value below limit of quantification |