Projects

CSEMP assessment of BDE28 in biota at Morecambe Bay

Statistical analysis

Trend assessment

Analysis of variance

 DfAICAICcLog likDevianceChisqChi dfPr(>Chisq)
mean162.5367.03-28.2656.53
linear259.0569.71-25.5251.055.479 10.0192
smooth (df = 2)360.7485.74-25.3750.740.306 10.5799

Change in log concentration

 Year startYear endFit startFit endChangeStd errortPr(>|t|)
overall20062016-2.021-2.989-0.9680 0.3274-2.9570.0316
last 20 years20062016-2.021-2.989-0.9680 0.3274-2.9570.0316

Status assessment

 Conc fittedConc refLog ratioStd errortPr(>t)
BAC 0.05 0.01-1.434 0.223-6.4270.9993
FEQG 0.05120.00 7.776 0.22334.854<0.0001

 


Raw data with supporting information

Raw data with supporting information for assessment of  BDE28 in biota at Morecambe Bay


Raw data with assessment

Raw data with assessment of  BDE28 in biota at Morecambe Bay


Assessment plot

Assessment plot for  BDE28 in biota at Morecambe Bay


Organo-bromines data

Organo-bromines data for assessment of  BDE28 in biota at Morecambe Bay


Organo-bromines assessment

Organo-bromines assessment of  BDE28 in biota at Morecambe Bay