Projects

CSEMP assessment of CB101 in sediment at Fladen Ground

Statistical analysis

Trend assessment

Analysis of variance

 DfAICAICcLog likDevianceChisqChi dfPr(>Chisq)
mean159.0768.07-26.5453.07
linear257.0889.08-24.5449.083.987 10.0458

Change in log concentration

 Year startYear endFit startFit endChangeStd errortPr(>|t|)
overall20052013-0.9784-2.8092-1.8308 0.8894-2.0580.1317
last 20 years20052013-0.9784-2.8092-1.8308 0.8894-2.0580.1317

Status assessment

 Conc fittedConc refLog ratioStd errortPr(>t)
BAC0.06030.14000.8430.4951.7040.0934
EAC0.06033.00003.9080.4957.9000.0021

 


Raw data with supporting information

Raw data with supporting information for assessment of  CB101 in sediment at Fladen Ground


Raw data with assessment

Raw data with assessment of  CB101 in sediment at Fladen Ground


Assessment plot

Assessment plot for  CB101 in sediment at Fladen Ground


Chlorobiphenyls data

Chlorobiphenyls data for assessment of  CB101 in sediment at Fladen Ground


Chlorobiphenyls assessment

Chlorobiphenyls assessment of  CB101 in sediment at Fladen Ground


Related pages