CD176 Discrete Dissolved Inorganic Nutrients Sampling Document

Originator's Protocol for Data Acquisition and Analysis

Water samples were collected from CTD stations throughout the cruise for the analysis of dissolved inorganic nutrients using an onboard Lachet Quickchem 8000 colorimetric flow injection autoanalyser. Shortly after the cruise started a fault developed with the autosampler, which prevented further onboard analysis. Subsequent samples were collected and filtered through GF/F 0.7 µm filters, before being frozen for analysis back at SAMS.

References Cited

Sherwin, T. A. et al , (2005) 'Cruise CD176 Birkenhead to Falmouth via Rockall, Iceland and Oban', Internal Report No 248, Scottish Association for Marine Science.

Available - Cruise CD176 Internal Report

BODC Data Processing Procedures

The nutrient data were supplied to BODC in Microsoft Excel spreadsheets. Values were extracted from these and loaded into BODC's ocean database under an ORACLE Relational Database Management System. Data that were considered unrealistic were flagged suspect.

Several inconsistencies were noted between the cruise report CTD logsheets and the originator spreadsheets relating to particular Niskin bottles sampled. In all cases the uncertainty involves multiple bottles fired at the same depth, so assignment to bottle numbers was deemed somewhat arbitrary.

Data listed out from the BODC database are done so at a resolution deemed appropriate for that particular variable and the analytical procedure involved. In some instances this results in the listing out of zero values.

SAMS nitrate data quality warning

SAMS have notified BODC of a problem in the analytical procedure adopted for nitrate analysis on this cruise. The problem relates to the technique used to prepare the analytical standards, which results in nitrate (and consequently nitrite) values which are typically 10-15 % higher than they should be. Absolute data values should therefore be used with extreme caution.

Content of data series

Originator's Parameter Unit Description BODC Parameter code BODC Unit Comments
Nitrate and nitrite µmol/l Concentration of nitrate and nitrite in the water column by colorimetric autoanalysis (unfiltered) NTRZAATX µmol/l n/a
Standard deviation of nitrate and nitrite µmol/l Concentration standard deviation of nitrate and nitrite in the water column by colorimetric autoanalysis (unfiltered) SDNZAATX µmol/l n/a
Phosphate µmol/l Concentration of phosphate in the water column by colorimetric autoanalysis (unfiltered) PHOSAATX µmol/l n/a
Standard deviation of phosphate µmol/l Concentration standard deviation of phosphate in the water column by colorimetric autoanalysis (unfiltered) SDPHAATX µmol/l n/a
Silicate µmol/l Concentration of silicate in the water column by colorimetric autoanalysis (unfiltered) SLCAAATX µmol/l n/a
Standard deviation of silicate µmol/l Concentration standard deviation of silicate in the water column by colorimetric autoanalysis (unfiltered) SLSDAATX µmol/l n/a
Nitrite µmol/l Concentration of nitrite in the water body by filtration and colorimetric autoanalysis NTRIAAD1 µmol/l n/a
Standard deviation of nitrite µmol/l Concentration standard deviation of nitrite in the water column by filtration and colorimetric autoanalysis SDNIAAD1 µmol/l n/a
Nitrate and nitrite µmol/l Concentration of nitrate and nitrite in the water column by filtration and colorimetric autoanalysis NTRZAAD1 µmol/l n/a
Standard deviation of nitrate and nitrite µmol/l Concentration standard deviation of nitrate and nitrite in the water column by filtration and colorimetric autoanalysis SDNZAAD1 µmol/l n/a
Ammonium µmol/l Concentration of ammonium in the water column by filtration and colorimetric autoanalysis AMONAAD1 µmol/l n/a
Standard deviation of ammonium µmol/l Concentration standard deviation of ammonium in the water column by filtration and colorimetric autoanalysis SDAMAAD1 µmol/l n/a
Phosphate µmol/l Concentration of phosphate in the water column by filtration and colorimetric autoanalysis PHOSAAD1 µmol/l n/a
Standard deviation of phosphate µmol/l Concentration standard deviation of phosphate in the water column by filtration and colorimetric autoanalysis SDPHAAD1 µmol/l n/a
Silicate µmol/l Concentration of silicate in the water column by filtration and colorimetric autoanalysis SLCAAAD1 µmol/l n/a
Standard deviation of silicate µmol/l Concentration standard deviation of silicate in the water column by filtration and colorimetric autoanalysis SDSLAAD1 µmol/l n/a