Search the data

AMT19 (JC039) pigment composition by HPLC analysis from surface underway samples

Data Acquisition and Analysis

Fresh seawater samples from the ship's non-toxic supply were collected during the cruise. 2-4 L of seawater were filtered through Whatman GF/F filters and the filters stored at -80°C. HPLC analysis was carried out after Van Heukelem and Thomas (2001).

References Cited

Van Heukelem, L. and Thomas, C. S. (2001). Computer-assisted high performance liquid chromatography method development with applications to the isolation and analysis of phytoplankton pigments, Journal of Chromatography A, 910, 31-49.

Instrumentation Description

Section not relevant.

BODC Data Processing Procedures

Data were submitted to BODC in the SeaBASS text format and saved to the archive with reference PML110038. The file was provided to BODC with date, time (in GMT), latitude, longitude and sample depth as metadata.

Sample metadata were checked against information held in the cruise report - there was one discrepancy where all sample depths provided were 5m except one which was provided as 0m, this was confirmed as a typo with the data originator. The metadata were loaded to the database.

Parameter codes defined in BODC parameter dictionary were assigned to the variables as shown in the table below. The data were provided in mg m -3 units and these were converted to ng l -1 for all parameters but chlorophyll-a. Three parameters were not loaded to the database (Tot chl-a, Tot chl-b and Tot chl-c) as these were derived by aggregating other parameters in the dataset. These parameters can be derived from the following parameters:

Tot_Chl_a = Chl_a + DV_Chl_a + Chlide_a

Tot_Chl_b = Chl_b + DV_Chl_b

Tot_Chl_c = Chl_c1c2 + Chl_c3

There were 18 sample events with data from replicate samples provided and these data were averaged and the mean and standard deviation values loaded to the database for each sampling event.

Data loaded into BODC's database according to protocols.

Originator's Parameter Units Description BODC Parameter Code Units Comments
Chl_a mg m -3 Concentration of chlorophyll-a {chl-a} per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) CPHLHPP1 mg m -3 n/a
Chl_a standard deviation mg m -3 Concentration standard deviation of chlorophyll-a {chl-a} per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) SDCLHPP1 mg m -3 n/a
DV_Chl_a mg m -3 Concentration of divinyl chlorophyll-a per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) DVCAHPP1 ng l -1 Unit conversion x1000 applied
DV_Chl_a standard deviation mg m -3 Concentration standard deviation of divinyl chlorophyll-a per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) DVCASDP1 ng l -1 Unit conversion x1000 applied
Chlide_a mg m -3 Concentration of chlorophyllide-a per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) CIDAHPP1 ng l -1 Unit conversion x1000 applied
Chlide_a standard deviation mg m -3 Concentration standard deviation of chlorophyllide-a per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) CIDASDP1 ng l -1 Unit conversion x1000 applied
Chl_b mg m -3 Concentration of chlorophyll-b {chl-b} per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) CHLBHPP1 ng l -1 Unit conversion x1000 applied
Chl_b standard deviation mg m -3 Concentration standard deviation of chlorophyll-b {chl-b} per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) CHLBSDP1 ng l -1 Unit conversion x1000 applied
DV_Chl_b mg m -3 Concentration of divinyl chlorophyll-b per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) DVCBHPP1 ng l -1 Unit conversion x1000 applied
DV_Chl_b standard deviation mg m -3 Concentration standard deviation of divinyl chlorophyll-b per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) DVCBSDP1 ng l -1 Unit conversion x1000 applied
Chl_c1c2 mg m -3 Concentration of chlorophyll-c1c2 {chl-c1c2} per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) C1C2HPP1 ng l -1 Unit conversion x1000 applied
Chl_c1c2 standard deviation mg m -3 Concentration standard deviation of chlorophyll-c1c2 {chl-c1c2} per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) C1C2SDP1 ng l -1 Unit conversion x1000 applied
Chl_c3 mg m -3 Concentration of chlorophyll-c3 {chl-c3} per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) CLC3HPP1 ng l -1 Unit conversion x1000 applied
Chl_c3 standard deviation mg m -3 Concentration standard deviation of chlorophyll-c3 {chl-c3} per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) CLC3SDP1 ng l -1 Unit conversion x1000 applied
alpha-beta-Car mg m -3 Concentration of alpha,beta-carotene {beta,epsilon-carotene} per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) ABCRHPP1 ng l -1 Unit conversion x1000 applied
alpha-beta-Car standard deviation mg m -3 Concentration standard deviation of alpha,beta-carotene {beta,epsilon-carotene} per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) ABCRSDP1 ng l -1 Unit conversion x1000 applied
But-fuco mg m -3 Concentration of 19'-butanoyloxyfucoxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) BUTAHPP1 ng l -1 Unit conversion x1000 applied
But-fuco standard deviation mg m -3 Concentration standard deviation of 19'-butanoyloxyfucoxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) BUTASDP1 ng l -1 Unit conversion x1000 applied
Hex-fuco mg m -3 Concentration of 19'-hexanoyloxyfucoxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) HEXOHPP1 ng l -1 Unit conversion x1000 applied
Hex-fuco standard deviation mg m -3 Concentration standard deviation of 19'-hexanoyloxyfucoxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) HEXOSDP1 ng l -1 Unit conversion x1000 applied
Allo mg m -3 Concentration of alloxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) ALLOHPP1 ng l -1 Unit conversion x1000 applied
Allo standard deviation mg m -3 Concentration standard deviation of alloxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) ALLOSDP1 ng l -1 Unit conversion x1000 applied
Diadino mg m -3 Concentration of diadinoxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) DIADHPP1 ng l -1 Unit conversion x1000 applied
Diadino standard deviation mg m -3 Concentration standard deviation of diadinoxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) DIADSDP1 ng l -1 Unit conversion x1000 applied
Diato mg m -3 Concentration of diatoxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) DIATHPP1 ng l -1 Unit conversion x1000 applied
Diato standard deviation mg m -3 Concentration standard deviation of diatoxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) DIATSDP1 ng l -1 Unit conversion x1000 applied
Fuco mg m -3 Concentration of fucoxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) FUCXHPP1 ng l -1 Unit conversion x1000 applied
Fuco standard deviation mg m -3 Concentration standard deviation of fucoxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) FUCXSDP1 ng l -1 Unit conversion x1000 applied
Perid mg m -3 Concentration of peridinin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) PERIHPP1 ng l -1 Unit conversion x1000 applied
Perid standard deviation mg m -3 Concentration standard deviation of peridinin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) PERISDP1 ng l -1 Unit conversion x1000 applied
Zea mg m -3 Concentration of zeaxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) ZEOXHPP1 ng l -1 Unit conversion x1000 applied
Zea standard deviation mg m -3 Concentration standard deviation of zeaxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) ZEOXSDP1 ng l -1 Unit conversion x1000 applied
Lut mg m -3 Concentration of lutein per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) LUTNHPP1 ng l -1 Unit conversion x1000 applied
Lut standard deviation mg m -3 Concentration standard deviation of lutein per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) LUTNSDP1 ng l -1 Unit conversion x1000 applied
Neo mg m -3 Concentration of neoxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) NEOXHPP1 ng l -1 Unit conversion x1000 applied
Neo standard deviation mg m -3 Concentration standard deviation of neoxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) NEOXSDP1 ng l -1 Unit conversion x1000 applied
Viola mg m -3 Concentration of violaxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) VILXHPP1 ng l -1 Unit conversion x1000 applied
Viola standard deviation mg m -3 Concentration standard deviation of violaxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) VILXSDP1 ng l -1 Unit conversion x1000 applied
Phytin_a mg m -3 Concentration of phaeophytin-a per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) PTAXHPP1 ng l -1 Unit conversion x1000 applied
Phytin_a standard deviation mg m -3 Concentration standard deviation of phaeophytin-a per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) PTAXSDP1 ng l -1 Unit conversion x1000 applied
Phide_a mg m -3 Concentration of phaeophorbide-a per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) PBAXHPP1 ng l -1 Unit conversion x1000 applied
Phide_a standard deviation mg m -3 Concentration standard deviation of phaeophorbide-a per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) PBAXSDP1 ng l -1 Unit conversion x1000 applied
Pras mg m -3 Concentration of prasinoxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) PRSXHPP1 ng l -1 Unit conversion x1000 applied
Pras standard deviation mg m -3 Concentration standard deviation of prasinoxanthin per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) PRSXSDP1 ng l -1 Unit conversion x1000 applied
Gyro mg m -3 Concentration of gyroxanthin diester per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) GDHPLC01 ng l -1 Unit conversion x1000 applied
Gyro standard deviation mg m -3 Concentration standard deviation of gyroxanthin diester per unit volume of the water column [particulate >GF/F phase] by filtration, acetone extraction and high performance liquid chromatography (HPLC) GDIESDP1 ng l -1 Unit conversion x1000 applied

Data Quality Report

The data originator also confirmed that values provided in the file of 0.001 mg m -3 were the detection limit. All these values have been flagged accordingly with the BODC flag for data below the detection limit.

BODC were not advised by the data originator of any further QC having taken place.

Problem Report