Search the data

Metadata Report for BODC Series Reference Number 1281136


Metadata Summary

Data Description

Data Category Water sample data
Instrument Type
NameCategories
General Oceanics GO-FLO water sampler  discrete water samplers
Instrument Mounting lowered unmanned submersible
Originating Country United Kingdom
Originator Prof Raymond Pollard
Originating Organization James Rennell Centre for Ocean Circulation (now National Oceanography Centre, Southampton)
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) UK WOCE
 

Data Identifiers

Originator's Identifier CD62_CTD_NUTS_32:CTD62038
BODC Series Reference 1281136
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 1991-08-14 18:55
End Time (yyyy-mm-dd hh:mm) -
Nominal Cycle Interval -
 

Spatial Co-ordinates

Latitude 59.11724 N ( 59° 7.0' N )
Longitude 33.64297 W ( 33° 38.6' W )
Positional Uncertainty Unspecified
Minimum Sensor or Sampling Depth 7.1 m
Maximum Sensor or Sampling Depth 2256.0 m
Minimum Sensor or Sampling Height 119.3 m
Maximum Sensor or Sampling Height 2368.2 m
Sea Floor Depth 2375.3 m
Sea Floor Depth Source -
Sensor or Sampling Distribution Unspecified -
Sensor or Sampling Depth Datum Unspecified -
Sea Floor Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
 

Parameters

BODC CODERankUnitsTitle
ADEPZZ011MetresDepth (spatial coordinate) relative to water surface in the water body
BOTTFLAG1Not applicableSampling process quality flag (BODC C22)
NTRZAATX1Micromoles per litreConcentration of nitrate+nitrite {NO3+NO2} per unit volume of the water body [dissolved plus reactive particulate phase] by colorimetric autoanalysis
SAMPRFNM1DimensionlessSample reference number
SLCAAATX1Micromoles per litreConcentration of silicate {SiO44- CAS 17181-37-2} per unit volume of the water body [dissolved plus reactive particulate phase] by colorimetric autoanalysis

Definition of BOTTFLAG

BOTTFLAGDefinition
0The sampling event occurred without any incident being reported to BODC.
1The filter in an in-situ sampling pump physically ruptured during sample resulting in an unquantifiable loss of sampled material.
2Analytical evidence (e.g. surface water salinity measured on a sample collected at depth) indicates that the water sample has been contaminated by water from depths other than the depths of sampling.
3The feedback indicator on the deck unit reported that the bottle closure command had failed. General Oceanics deck units used on NERC vessels in the 80s and 90s were renowned for reporting misfires when the bottle had been closed. This flag is also suitable for when a trigger command is mistakenly sent to a bottle that has previously been fired.
4During the sampling deployment the bottle was fired in an order other than incrementing rosette position. Indicative of the potential for errors in the assignment of bottle firing depth, especially with General Oceanics rosettes.
5Water was reported to be escaping from the bottle as the rosette was being recovered.
6The bottle seals were observed to be incorrectly seated and the bottle was only part full of water on recovery.
7Either the bottle was found to contain no sample on recovery or there was no bottle fitted to the rosette position fired (but SBE35 record may exist).
8There is reason to doubt the accuracy of the sampling depth associated with the sample.
9The bottle air vent had not been closed prior to deployment giving rise to a risk of sample contamination through leakage.

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database


Data Access Policy

Public domain data

These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.

The recommended acknowledgment is

"This study uses data from the data source/organisation/programme, provided by the British Oceanographic Data Centre and funded by the funding body."


Narrative Documents

GO-FLO Bottle

A water sampling bottle featuring close-open-close operation. The bottle opens automatically at approximately 10 metres and flushes until closed. Sampling with these bottles avoids contamination at the surface, internal spring contamination, loss of sample on deck and exchange of water from different depths.

There are several sizes available, from 1.7 to 100 litres and are made of PVC with a depth rating of up to 500 m. These bottles can be attached to a rosette or placed on a cable at selected positions.


Project Information

UK WOCE

The UK made a substantial contribution to the international World Ocean Circulation Experiment (WOCE) project by focusing on two important regions:

  1. Southern Ocean - links all the worlds oceans, controlling global climate.
  2. North Atlantic - directly affects the climate of Europe.

A major part of the UK effort was in the Southern Ocean and work included:

  • Two surveys, in the South Atlantic as part of the WOCE Hydrographic Programme.
  • SWINDEX, a year long study of the Antarctic Circumpolar Current (ACC) where it crosses major topography south of Africa.
  • ADOX, a study of deep water flow from the Atlantic to the Indian Ocean.
  • ACCLAIM, a study of the ACC by altimetry and island measurements.

In the North Atlantic the UK undertook:

  • NATRE, a purposeful tracer experiment to look at cross isopycnic processes.
  • CONVEX, a study of the deep ocean circulation and its changes.
  • VIVALDI, a seven year programme of seasonally repeated surveys to study the upper ocean.
  • Long-term observations of ocean climate in the North West Approaches.

Satellite ocean surface topography, temperature and wind data were merged with in situ observations and models to create a complete description of ocean circulation, eddy motion and the way the ocean is driven by the atmosphere.

The surveys were forerunners to the international Global Ocean Observing System (GOOS). GOOS was later established to monitor annual to decadal changes in ocean circulation and heat storage which are vital in the prediction of climate change.


Data Activity or Cruise Information

Data Activity

Start Date (yyyy-mm-dd) 1991-08-14
End Date (yyyy-mm-dd) 1991-08-14
Organization Undertaking ActivityInstitute of Oceanographic Sciences Deacon Laboratory (now National Oceanography Centre, Southampton)
Country of OrganizationUnited Kingdom
Originator's Data Activity IdentifierCD62_CTD_CTD62038
Platform Categorylowered unmanned submersible

BODC Sample Metadata Report for CD62_CTD_CTD62038

Sample reference number Nominal collection volume(l) Bottle rosette position Bottle firing sequence number Minimum pressure sampled (dbar) Maximum pressure sampled (dbar) Depth of sampling point (m) Bottle type Sample quality flag Bottle reference Comments
85868   10.00       57.20   58.70   56.30 General Oceanics GO-FLO water sampler No problem reported    
85869   10.00      105.20  106.70  103.80 General Oceanics GO-FLO water sampler No problem reported    
85870   10.00      207.20  208.70  204.80 General Oceanics GO-FLO water sampler No problem reported    
85871   10.00      255.30  256.80  252.40 General Oceanics GO-FLO water sampler No problem reported    
85872   10.00      305.60  307.10  302.10 General Oceanics GO-FLO water sampler No problem reported    
85873   10.00      759.10  760.60  750.20 General Oceanics GO-FLO water sampler No problem reported    
85874   10.00     1265.10 1266.60 1249.10 General Oceanics GO-FLO water sampler No problem reported    
85875   10.00     1514.70 1516.20 1494.70 General Oceanics GO-FLO water sampler No problem reported    
85876   10.00     1758.60 1760.10 1734.40 General Oceanics GO-FLO water sampler No problem reported    
85877   10.00     2290.20 2291.70 2256.00 General Oceanics GO-FLO water sampler No problem reported    
86338   10.00        7.60    9.10    7.10 General Oceanics GO-FLO water sampler No problem reported    
86339   10.00      505.20  506.70  499.50 General Oceanics GO-FLO water sampler No problem reported    
86340   10.00     2004.60 2006.10 1976.00 General Oceanics GO-FLO water sampler No problem reported    
86467   10.00       29.20   30.70   28.50 General Oceanics GO-FLO water sampler No problem reported    
86468   10.00     1011.30 1012.80  999.00 General Oceanics GO-FLO water sampler No problem reported    

Please note:the supplied parameters may not have been sampled from all the bottle firings described in the table above. Cross-match the Sample Reference Number above against the SAMPRFNM value in the data file to identify the relevant metadata.

Cruise

Cruise Name CD62
Departure Date 1991-08-01
Arrival Date 1991-09-04
Principal Scientist(s)W John Gould (Institute of Oceanographic Sciences Deacon Laboratory)
Ship RRS Charles Darwin

Complete Cruise Metadata Report is available here


Fixed Station Information


No Fixed Station Information held for the Series


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification