Metadata Report for BODC Series Reference Number 1374325
Metadata Summary
Problem Reports
Data Access Policy
Narrative Documents
Project Information
Data Activity or Cruise Information
Fixed Station Information
BODC Quality Flags
SeaDataNet Quality Flags
Metadata Summary
Data Description |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Data Identifiers |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Time Co-ordinates(UT) |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Spatial Co-ordinates | |||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Parameters |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
Problem Reports
No Problem Report Found in the Database
Data Access Policy
Public domain data
These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.
The recommended acknowledgment is
"This study uses data from the data source/organisation/programme, provided by the British Oceanographic Data Centre and funded by the funding body."
Narrative Documents
Sea-Bird SBE 37-SM MicroCAT
The SBE 37-SM MicroCAT is a high accuracy conductivity and temperature recorder (pressure optional). Designed for moorings and other long-duration, fixed-site deployments, MicroCATs have non-corroding titanium housings rated for operation to 7000 metres or pressure sensor full scale-range. Communication with the MicroCAT is over an internal, 3-wire, RS-232C link. The MicroCAT's aged and pressure-protected thermistor has a long history of exceptional accuracy and stability (typical drift is less than 0.002° per year). Electrical isolation of the conductivity electronics eliminates any possibility of ground-loop noise.
Specifications
Temperature (°C) | Conductivity (S m-1) | Optional Pressure | |
---|---|---|---|
Measurement Range | -5 to +35 | 0 to 7 (0 to 70 mS cm-1) | 0 to full scale range: 20 / 100 / 350 / 1000 / 2000 / 3500 / 7000 metres |
Initial accuracy | 0.002 | 0.0003 | 0.1% of full scale range |
Typical Stability | 0.0002 per month | 0.0003 per month | 0.05% of full scale range per year |
Resolution | 0.0001 | 0.00001 | 0.002% of full scale range |
Sensor Calibration | +1 to +32 | 0 to 6; physical calibration over range 2.6 to 6 S m-1, plus zero conductivity (air) | Ambient pressure to full scale range in 5 steps |
Memory | 8 Mbyte non-volatile FLASH memory | ||
Data Storage | Converted temperature and conductivity: 6 bytes per sample (3 bytes each) Time: 4 bytes per sample Pressure (optional): 5 bytes per sample | ||
Real-Time Clock | 32,768 Hz TCXO accurate to ±1 minutes year-1 | ||
Standard Internal Batteries | Nominal 10.6 Ampere-hour pack consisting of 12 AA lithium batteries. Provides sufficient capacity for more than 630,000 samples for a typical sampling scheme | ||
Housing | Titanium pressure case rated at 7000 metres | ||
Weight (without pressure) | In water: 2.3 kg In air: 3.8 kg |
Further information can be found via the following link: SBE 37-SM MicroCAT Datasheet
BODC Processing
Data were received in ASCII format files. The series were transferred to BODC's in-house format. The following table shows how the variables within the file were mapped to the appropriate BODC parameter codes.
Original parameter name | Original Units | BODC Parameter Code | BODC Units | Comments |
---|---|---|---|---|
Pressure | decibars | PREXPS01 | decibars | Not recorded at all moorings |
Temperature | °C | TEMPPR01 | °C | |
Salinity | PSU | PSALPR01 | Dimensionless | Not recorded at all moorings |
Following transfer to QXF, the data were visually screened using in house BODC software. Any data considered as suspect were flagged accordingly. The originator's quality control flags were retained during transfer.
Originator's Data Processing
Marine Scotland applied the standard manufacturers' calibrations to all data and produced ASCII files for submission to BODC. Data files (.hmo) were named according to the mooring code and the instrument number. The file contained pressure and/or temperature. Salinity data, where available, were contained in a file appended 's'. Header metadata were collated in an additional file (.frm).
Project Information
No Project Information held for the Series
Data Activity or Cruise Information
Data Activity
Start Date (yyyy-mm-dd) | 2013-05-15 |
End Date (yyyy-mm-dd) | 2014-04-28 |
Organization Undertaking Activity | Marine Scotland Aberdeen Marine Laboratory |
Country of Organization | United Kingdom |
Originator's Data Activity Identifier | 840 |
Platform Category | subsurface mooring |
Marine Scotland CTD mooring (840), NW of Shetland
The Sea-Bird SBE37 CTD was located at 59° 54.32' N, 06° 10.19' W in a nominal water depth of 774 m.
The SBE37 SM was deployed on 15th May 2013 by Marine Scotland from cruise FRV Scotia 0513S and recovered on 28th April 2014. Instrumentation details are included in the following table.
Instrument type | Serial Number | Deployment start | Deployment end | Instrument depth (m) | Comments |
---|---|---|---|---|---|
SBE37 SM | 10124 | 15-05-2013 | 28-04-2014 | 767 |
Cruise
Cruise Name | 0513S |
Departure Date | 2013-05-10 |
Arrival Date | 2013-05-24 |
Principal Scientist(s) | George Slesser (Marine Scotland Aberdeen Marine Laboratory) |
Ship | FRV Scotia |
Complete Cruise Metadata Report is available here
Fixed Station Information
No Fixed Station Information held for the Series
BODC Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
Blank | Unqualified |
< | Below detection limit |
> | In excess of quoted value |
A | Taxonomic flag for affinis (aff.) |
B | Beginning of CTD Down/Up Cast |
C | Taxonomic flag for confer (cf.) |
D | Thermometric depth |
E | End of CTD Down/Up Cast |
G | Non-taxonomic biological characteristic uncertainty |
H | Extrapolated value |
I | Taxonomic flag for single species (sp.) |
K | Improbable value - unknown quality control source |
L | Improbable value - originator's quality control |
M | Improbable value - BODC quality control |
N | Null value |
O | Improbable value - user quality control |
P | Trace/calm |
Q | Indeterminate |
R | Replacement value |
S | Estimated value |
T | Interpolated value |
U | Uncalibrated |
W | Control value |
X | Excessive difference |
SeaDataNet Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
0 | no quality control |
1 | good value |
2 | probably good value |
3 | probably bad value |
4 | bad value |
5 | changed value |
6 | value below detection |
7 | value in excess |
8 | interpolated value |
9 | missing value |
A | value phenomenon uncertain |
B | nominal value |
Q | value below limit of quantification |