Search the data

Metadata Report for BODC Series Reference Number 1851995


Metadata Summary

Data Description

Data Category Water sample data
Instrument Type
NameCategories
Skalar SAN+ System colorimetric autoanalyser  colorimeters; autoanalysers
Niskin bottle  discrete water samplers
Instrument Mounting lowered unmanned submersible
Originating Country United Kingdom
Originator Dr Brian King
Originating Organization National Oceanography Centre, Southampton
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) Oceans 2025
 

Data Identifiers

Originator's Identifier D368_CTD_NUTS_52:CTD029
BODC Series Reference 1851995
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 2011-08-03 23:39
End Time (yyyy-mm-dd hh:mm) -
Nominal Cycle Interval -
 

Spatial Co-ordinates

Latitude 28.78200 N ( 28° 46.9' N )
Longitude 16.00160 W ( 16° 0.1' W )
Positional Uncertainty 0.0 to 0.01 n.miles
Minimum Sensor or Sampling Depth 5.0 m
Maximum Sensor or Sampling Depth 2959.0 m
Minimum Sensor or Sampling Height 513.9 m
Maximum Sensor or Sampling Height 3467.9 m
Sea Floor Depth 3472.9 m
Sea Floor Depth Source CTDDATA
Sensor or Sampling Distribution Unspecified -
Sensor or Sampling Depth Datum Unspecified -
Sea Floor Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
 

Parameters

BODC CODERankUnitsTitle
ADEPZZ011MetresDepth (spatial coordinate) relative to water surface in the water body
BOTTFLAG1Not applicableSampling process quality flag (BODC C22)
NTRZAATX1Micromoles per litreConcentration of nitrate+nitrite {NO3+NO2} per unit volume of the water body [dissolved plus reactive particulate phase] by colorimetric autoanalysis
PHOSAATX1Micromoles per litreConcentration of phosphate {PO43- CAS 14265-44-2} per unit volume of the water body [dissolved plus reactive particulate phase] by colorimetric autoanalysis
ROSPOSID1DimensionlessBottle rosette position identifier
SAMPRFNM1DimensionlessSample reference number
SLCAAATX1Micromoles per litreConcentration of silicate {SiO44- CAS 17181-37-2} per unit volume of the water body [dissolved plus reactive particulate phase] by colorimetric autoanalysis

Definition of BOTTFLAG

BOTTFLAGDefinition
0The sampling event occurred without any incident being reported to BODC.
1The filter in an in-situ sampling pump physically ruptured during sample resulting in an unquantifiable loss of sampled material.
2Analytical evidence (e.g. surface water salinity measured on a sample collected at depth) indicates that the water sample has been contaminated by water from depths other than the depths of sampling.
3The feedback indicator on the deck unit reported that the bottle closure command had failed. General Oceanics deck units used on NERC vessels in the 80s and 90s were renowned for reporting misfires when the bottle had been closed. This flag is also suitable for when a trigger command is mistakenly sent to a bottle that has previously been fired.
4During the sampling deployment the bottle was fired in an order other than incrementing rosette position. Indicative of the potential for errors in the assignment of bottle firing depth, especially with General Oceanics rosettes.
5Water was reported to be escaping from the bottle as the rosette was being recovered.
6The bottle seals were observed to be incorrectly seated and the bottle was only part full of water on recovery.
7Either the bottle was found to contain no sample on recovery or there was no bottle fitted to the rosette position fired (but SBE35 record may exist).
8There is reason to doubt the accuracy of the sampling depth associated with the sample.
9The bottle air vent had not been closed prior to deployment giving rise to a risk of sample contamination through leakage.

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database


Data Access Policy

Open Data supplied by Natural Environment Research Council (NERC)

You must always use the following attribution statement to acknowledge the source of the information: "Contains data supplied by Natural Environment Research Council."


Narrative Documents

Skalar San+ Autoanalyzer

The San+ Autoanalyzer is an Automated Wet Chemistry Analyzer (Continuous Flow Analyzer) which has been designed as a modular system to measure a variety of water chemistry characteristics, such as nutrient concentrations in seawater. Individual modules are tailored to specific needs. It uses Continuous Flow Analysis (CFA), allowing up to 16 analytical measurements to be made on a single sample simultaneously. The system comprises a sampler, chemistry section, detector and specialist software.

Chemistry section
The San+ includes a chemistry section which has hundreds of applications. It houses up to five chemistry cartridges with built-in dosing pump and air injection systems, up to five interchangeable cartridges with build-in photometric detectors and five separate waste receptacles. The throughput of the analyser depends upon application and can vary from 25 to 120 analyses per hour. It has a double diameter pump deck for accurate dosing with 32 pump tubes, two separated pump decks for 2 x 2 channel concept, and controlled synchronised eight channel air injection with separate built-in compressor for increased flow stability and fast start-up. It has easy access to chemistry cartridges with flexible ultra low carry-over connections between dialysers, reactors, coils, flow cells and other components, leak detection, 3-cuffs long life pump tubes, and has manually operated and automatic rinsing valves for easy automatic start up and overnight operation.

Detectors
The San+ range of detectors comprises dual channel colorimetric detectors, the unique matrix correction detector with automatic background correction for difficult sample matrixes, but also covers a range of detectors for I.R., U.V., fluorimetry, ISE, flame photometry, refractometers, density meters, etc.

Software
The San+ 'Flow Access' windows software package controls the complete analyser, with auto start-up, function control, and auto-scaling, pre-and post run sample dilutions, result calculation and statistics. Up to 16 channels can be handled simultaneously, with multiple samplers, and chemistries can be grouped for analysis.

The San+ is also known as San++.

Niskin Bottle

The Niskin bottle is a device used by oceanographers to collect subsurface seawater samples. It is a plastic bottle with caps and rubber seals at each end and is deployed with the caps held open, allowing free-flushing of the bottle as it moves through the water column.

Standard Niskin

The standard version of the bottle includes a plastic-coated metal spring or elastic cord running through the interior of the bottle that joins the two caps, and the caps are held open against the spring by plastic lanyards. When the bottle reaches the desired depth the lanyards are released by a pressure-actuated switch, command signal or messenger weight and the caps are forced shut and sealed, trapping the seawater sample.

Lever Action Niskin

The Lever Action Niskin Bottle differs from the standard version, in that the caps are held open during deployment by externally mounted stainless steel springs rather than an internal spring or cord. Lever Action Niskins are recommended for applications where a completely clear sample chamber is critical or for use in deep cold water.

Clean Sampling

A modified version of the standard Niskin bottle has been developed for clean sampling. This is teflon-coated and uses a latex cord to close the caps rather than a metal spring. The clean version of the Levered Action Niskin bottle is also teflon-coated and uses epoxy covered springs in place of the stainless steel springs. These bottles are specifically designed to minimise metal contamination when sampling trace metals.

Deployment

Bottles may be deployed singly clamped to a wire or in groups of up to 48 on a rosette. Standard bottles and Lever Action bottles have a capacity between 1.7 and 30 L. Reversing thermometers may be attached to a spring-loaded disk that rotates through 180° on bottle closure.

Discrete inorganic nutrients from CTD bottles on RRS Discovery Cruise D368

Originator's Protocol for Data Acquisition and Analysis

The nutrients were taken in polypropylene tubes which were previously cleaned and washed with HCl acid and were completely dry. Samples were duplicated and were immediately frozen at -20°C, to analyze them as soon as possible ashore. The nutrient determination ashore will be performed with a segmented continuous-flow autoanalyser, a Skalar San Plus System in the ICCM laboratory.

Nitrate+Nitrite: The automated procedure for the determination of nitrate and nitrite is based on the cadmium reduction method; the sample is passed through a column containing granulated copper-cadmium to reduce the nitrate to nitrite, using ammonium chloride as pH controller and complexer of the cadmium cations formed.

Phosphate: The automated procedure for the determination of phosphate is based on the following reaction: ammonium molybdate and potassium antimony tartrate react in an acidic medium with diluted solution of phosphate to form an antimony-phospho-molybdate complex. This complex is reduced to an intensely blue-coloured complex, ascorbic acid. The complex is measured at 880nm.

Silicate: The determination of the soluble silicon compounds in natural waters is based on the formation of the yellow coloured silicomolybdic acid; the sample is acidified and mixed with an ammonium molybdate solution forming molybdosilicic acid. This acid is reduced with ascorbic acid to a blue dye, which is measured at 810nm. Oxalic acid is added to avoid phosphate interference.

Please see the cruise report for further information.

BODC Data Processing Procedures

Data received were loaded into the BODC database using established BODC data banking procedures. The source file was the most processed and accurate version of the data.

The originator's parameters were mapped to BODC parameters as below:

Originator's Parameter Unit Description BODC Parameter code BODC Unit Comments
SILCAT µmol/kg Silicate from bottle sample determined by Auto Analyzer SLCAAATX µmol/kg n/a
NO2+NO3 µmol/kg Nitrate and nitrate from bottle sample determined by Auto Analyzer NTRZAATX µmol/kg n/a
PHSPHT µmol/kg Phosphate from bottle sample determined by Auto Analyzer PHOSAATX µmol/kg n/a

Data quality

No issues identified


Project Information

Oceans 2025 - The NERC Marine Centres' Strategic Research Programme 2007-2012

Who funds the programme?

The Natural Environment Research Council (NERC) funds the Oceans 2025 programme, which was originally planned in the context of NERC's 2002-2007 strategy and later realigned to NERC's subsequent strategy (Next Generation Science for Planet Earth; NERC 2007).

Who is involved in the programme?

The Oceans 2025 programme was designed by and is to be implemented through seven leading UK marine centres. The marine centres work together in coordination and are also supported by cooperation and input from government bodies, universities and other partners. The seven marine centres are:

  • National Oceanography Centre, Southampton (NOCS)
  • Plymouth Marine Laboratory (PML)
  • Marine Biological Association (MBA)
  • Sir Alister Hardy Foundation for Marine Science (SAHFOS)
  • Proudman Oceanographic Laboratory (POL)
  • Scottish Association for Marine Science (SAMS)
  • Sea Mammal Research Unit (SMRU)

Oceans2025 provides funding to three national marine facilities, which provide services to the wider UK marine community, in addition to the Oceans 2025 community. These facilities are:

  • British Oceanographic Data Centre (BODC), hosted at POL
  • Permanent Service for Mean Sea Level (PSMSL), hosted at POL
  • Culture Collection of Algae and Protozoa (CCAP), hosted at SAMS

The NERC-run Strategic Ocean Funding Initiative (SOFI) provides additional support to the programme by funding additional research projects and studentships that closely complement the Oceans 2025 programme, primarily through universities.

What is the programme about?

Oceans 2025 sets out to address some key challenges that face the UK as a result of a changing marine environment. The research funded through the programme sets out to increase understanding of the size, nature and impacts of these changes, with the aim to:

  • improve knowledge of how the seas behave, not just now but in the future;
  • help assess what that might mean for the Earth system and for society;
  • assist in developing sustainable solutions for the management of marine resources for future generations;
  • enhance the research capabilities and facilities available for UK marine science.

In order to address these aims there are nine science themes supported by the Oceans 2025 programme:

  • Climate, circulation and sea level (Theme 1)
  • Marine biogeochemical cycles (Theme 2)
  • Shelf and coastal processes (Theme 3)
  • Biodiversity and ecosystem functioning (Theme 4)
  • Continental margins and deep ocean (Theme 5)
  • Sustainable marine resources (Theme 6)
  • Technology development (Theme 8)
  • Next generation ocean prediction (Theme 9)
  • Integration of sustained observations in the marine environment (Theme 10)

In the original programme proposal there was a theme on health and human impacts (Theme 7). The elements of this Theme have subsequently been included in Themes 3 and 9.

When is the programme active?

The programme started in April 2007 with funding for 5 years.

Brief summary of the programme fieldwork/data

Programme fieldwork and data collection are to be achieved through:

  • physical, biological and chemical parameters sampling throughout the North and South Atlantic during collaborative research cruises aboard NERC's research vessels RRS Discovery, RRS James Cook and RRS James Clark Ross;
  • the Continuous Plankton Recorder being deployed by SAHFOS in the North Atlantic and North Pacific on 'ships of opportunity';
  • physical parameters measured and relayed in near real-time by fixed moorings and ARGO floats;
  • coastal and shelf sea observatory data (Liverpool Bay Coastal Observatory (LBCO) and Western Channel Observatory (WCO)) using the RV Prince Madog and RV Quest.

The data is to be fed into models for validation and future projections. Greater detail can be found in the Theme documents.


Data Activity or Cruise Information

Data Activity

Start Date (yyyy-mm-dd) 2011-08-03
End Date (yyyy-mm-dd) Ongoing
Organization Undertaking ActivityNational Oceanography Centre, Southampton
Country of OrganizationUnited Kingdom
Originator's Data Activity IdentifierD368_CTD_CTD029
Platform Categorylowered unmanned submersible

BODC Sample Metadata Report for D368_CTD_CTD029

Sample reference number Nominal collection volume(l) Bottle rosette position Bottle firing sequence number Minimum pressure sampled (dbar) Maximum pressure sampled (dbar) Depth of sampling point (m) Bottle type Sample quality flag Bottle reference Comments
1266623   10.00 2   3000.90 3001.90 2959.00 Niskin bottle No problem reported    
1266626   10.00 3   2799.60 2800.60 2761.80 Niskin bottle No problem reported    
1266629   10.00 4   2501.30 2502.30 2469.20 Niskin bottle No problem reported    
1266632   10.00 5   2000.00 2001.00 1976.50 Niskin bottle No problem reported    
1266635   10.00 6   1800.10 1801.10 1779.70 Niskin bottle No problem reported    
1266638   10.00 7   1499.90 1500.90 1483.90 Niskin bottle No problem reported    
1266641   10.00 8   1299.60 1300.60 1286.20 Niskin bottle No problem reported    
1266644   10.00 9   1198.90 1199.90 1186.80 Niskin bottle No problem reported    
1266647   10.00 10   1099.70 1100.70 1088.80 Niskin bottle No problem reported    
1266650   10.00 11   1000.50 1001.50  990.80 Niskin bottle No problem reported    
1266653   10.00 12    801.70  802.70  794.10 Niskin bottle No problem reported    
1266656   10.00 13    599.50  600.50  594.00 Niskin bottle No problem reported    
1266659   10.00 14    399.00  400.00  395.30 Niskin bottle No problem reported    
1266662   10.00 15    299.00  300.00  296.10 Niskin bottle No problem reported    
1266665   10.00 17    150.80  151.80  149.10 Niskin bottle No problem reported    
1266668   10.00 18    126.40  127.40  124.90 Niskin bottle No problem reported    
1266671   10.00 19     99.70  100.70   98.40 Niskin bottle No problem reported    
1266674   10.00 20     75.60   76.60   74.40 Niskin bottle No problem reported    
1266677   10.00 21     50.40   51.40   49.40 Niskin bottle No problem reported    
1266680   10.00 22     24.90   25.90   24.10 Niskin bottle No problem reported    
1266683   10.00 23     10.10   11.10    9.40 Niskin bottle No problem reported    
1266686   10.00 24      5.70    6.70    5.00 Niskin bottle No problem reported    

Please note:the supplied parameters may not have been sampled from all the bottle firings described in the table above. Cross-match the Sample Reference Number above against the SAMPRFNM value in the data file to identify the relevant metadata.

Cruise

Cruise Name D368
Departure Date 2011-07-15
Arrival Date 2011-08-04
Principal Scientist(s)Brian A King (National Oceanography Centre, Southampton)
Ship RRS Discovery

Complete Cruise Metadata Report is available here


Fixed Station Information


No Fixed Station Information held for the Series


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification