Search the data

Metadata Report for BODC Series Reference Number 1888861


Metadata Summary

Data Description

Data Category Water sample data
Instrument Type
NameCategories
Niskin bottle  discrete water samplers
Instrument Mounting lowered unmanned submersible
Originating Country United Kingdom
Originator Mrs Claire Widdicombe
Originating Organization Plymouth Marine Laboratory
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) Oceans 2025 Theme 10 SO1:AMT
 

Data Identifiers

Originator's Identifier JC039_CTD_PIGX_250:CTD002S
BODC Series Reference 1888861
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 2009-10-14 04:59
End Time (yyyy-mm-dd hh:mm) -
Nominal Cycle Interval -
 

Spatial Co-ordinates

Latitude 49.56700 N ( 49° 34.0' N )
Longitude 8.63352 W ( 8° 38.0' W )
Positional Uncertainty 0.05 to 0.1 n.miles
Minimum Sensor or Sampling Depth 1.4 m
Maximum Sensor or Sampling Depth 38.0 m
Minimum Sensor or Sampling Height 105.0 m
Maximum Sensor or Sampling Height 141.6 m
Sea Floor Depth 143.0 m
Sea Floor Depth Source PEVENT
Sensor or Sampling Distribution Unspecified -
Sensor or Sampling Depth Datum Unspecified -
Sea Floor Depth Datum Unspecified -
 

Parameters

BODC CODERankUnitsTitle
ADEPZZ011MetresDepth (spatial coordinate) relative to water surface in the water body
BOTTFLAG1Not applicableSampling process quality flag (BODC C22)
CPHLFLP41Milligrams per cubic metreConcentration of chlorophyll-a {chl-a CAS 479-61-8} per unit volume of the water body [particulate >0.2um phase] by filtration, acetone extraction and fluorometry and summation of size-fractionated values
FIRSEQID1DimensionlessBottle firing sequence number
ROSPOSID1DimensionlessBottle rosette position identifier
SAMPRFNM1DimensionlessSample reference number
SCHLFLPB1Milligrams per cubic metreConcentration of chlorophyll-a {chl-a CAS 479-61-8} per unit volume of the water body [particulate >2um phase] by filtration, acetone extraction and fluorometry
SCHLFLPF1Milligrams per cubic metreConcentration of chlorophyll-a {chl-a CAS 479-61-8} per unit volume of the water body [particulate 0.2-2um phase] by filtration, acetone extraction and fluorometry

Definition of BOTTFLAG

BOTTFLAGDefinition
0The sampling event occurred without any incident being reported to BODC.
1The filter in an in-situ sampling pump physically ruptured during sample resulting in an unquantifiable loss of sampled material.
2Analytical evidence (e.g. surface water salinity measured on a sample collected at depth) indicates that the water sample has been contaminated by water from depths other than the depths of sampling.
3The feedback indicator on the deck unit reported that the bottle closure command had failed. General Oceanics deck units used on NERC vessels in the 80s and 90s were renowned for reporting misfires when the bottle had been closed. This flag is also suitable for when a trigger command is mistakenly sent to a bottle that has previously been fired.
4During the sampling deployment the bottle was fired in an order other than incrementing rosette position. Indicative of the potential for errors in the assignment of bottle firing depth, especially with General Oceanics rosettes.
5Water was reported to be escaping from the bottle as the rosette was being recovered.
6The bottle seals were observed to be incorrectly seated and the bottle was only part full of water on recovery.
7Either the bottle was found to contain no sample on recovery or there was no bottle fitted to the rosette position fired (but SBE35 record may exist).
8There is reason to doubt the accuracy of the sampling depth associated with the sample.
9The bottle air vent had not been closed prior to deployment giving rise to a risk of sample contamination through leakage.

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database


Data Access Policy

Open Data supplied by Natural Environment Research Council (NERC)

You must always use the following attribution statement to acknowledge the source of the information: "Contains data supplied by Natural Environment Research Council."


Narrative Documents

Niskin Bottle

The Niskin bottle is a device used by oceanographers to collect subsurface seawater samples. It is a plastic bottle with caps and rubber seals at each end and is deployed with the caps held open, allowing free-flushing of the bottle as it moves through the water column.

Standard Niskin

The standard version of the bottle includes a plastic-coated metal spring or elastic cord running through the interior of the bottle that joins the two caps, and the caps are held open against the spring by plastic lanyards. When the bottle reaches the desired depth the lanyards are released by a pressure-actuated switch, command signal or messenger weight and the caps are forced shut and sealed, trapping the seawater sample.

Lever Action Niskin

The Lever Action Niskin Bottle differs from the standard version, in that the caps are held open during deployment by externally mounted stainless steel springs rather than an internal spring or cord. Lever Action Niskins are recommended for applications where a completely clear sample chamber is critical or for use in deep cold water.

Clean Sampling

A modified version of the standard Niskin bottle has been developed for clean sampling. This is teflon-coated and uses a latex cord to close the caps rather than a metal spring. The clean version of the Levered Action Niskin bottle is also teflon-coated and uses epoxy covered springs in place of the stainless steel springs. These bottles are specifically designed to minimise metal contamination when sampling trace metals.

Deployment

Bottles may be deployed singly clamped to a wire or in groups of up to 48 on a rosette. Standard bottles and Lever Action bottles have a capacity between 1.7 and 30 L. Reversing thermometers may be attached to a spring-loaded disk that rotates through 180° on bottle closure.

AMT19 (JC039) extracted chlorophyll-a measurements from CTD bottle samples

Originator's Protocol for Data Acquisition and Analysis

Samples were taken from 3 - 6 CTD rosette bottles to provide a calibration for the fluorometer measurements on each rig and to complement the primary production dataset. During the cruise 38 CTD casts were sampled and processed for extracted chl-a measurement.

250 ml samples of seawater collected from the rosette bottles were filtered through 2 µm and then 0.2 µm filters. The chlorophyl-a was then extracted from the filters with 10ml 90% acetone. The concentrations were then determined fluorometrically.

References Cited

Instrumentation Description

n/a

BODC Data Processing Procedures

Data were submitted in an Excel spreadsheet and archived under BODC's accession number PML100089. Sample metadata (date, time, Julian Day, latitude, longitude, cast, rosette bottle and depth) were provided with the data and were checked against records already in the database. There were no discrepancies.

No unit conversion was necessary as the units the data were supplied in the files matched the units for the parameter codes in the BODC Parameter Dictionary.

A parameter mapping table is provided below;

Originator's Parameter Units Description BODC Parameter Code Units Comments
Chlorophyll-a (>2 µm) mg m-3 Concentration of chlorophyll-a {chl-a} per unit volume of the water body [particulate >2µm phase] by filtration, acetone extraction and fluorometry SCHLFLPB mg m-3 n/a
Chlorophyll-a (0.2-2 µm) mg m-3 Concentration of chlorophyll-a {chl-a} per unit volume of the water body [particulate 0.2-2µm phase] by filtration, acetone extraction and fluorometry SCHLFLPF mg m-3 n/a
Chlorophyll-a (TOTAL) mg m-3 Concentration of chlorophyll-a {chl-a} per unit volume of the water body [particulate >0.2µm phase] by filtration, acetone extraction and fluorometry and summation of size-fractionated values CPHLFLP4 mg m-3 n/a

Data Quality Report

BODC were not advised by the data originator of any suspect data values in the dataset.

Problem Report

Not relevant to this data set.


Project Information

Oceans 2025 Theme 10, Sustained Observation Activity 1: The Atlantic Meridional Transect (AMT)

The Atlantic Meridional Transect has been operational since 1995 and through the Oceans 2025 programme secures funding for a further five cruises during the period 2007-2012. The AMT programme began in 1995 utilising the passage of the RRS James Clark Ross between the UK and the Falkland Islands southwards in September and northwards in April each year. Prior to Oceans 2025 the AMT programme has completed 18 cruises following this transect in the Atlantic Ocean. This sustained observing system aims to provide basin-scale understanding of the distribution of planktonic communities, their nutrient turnover and biogenic export in the context of hydrographic and biogeochemical provinces of the North and South Atlantic Oceans.

The Atlantic Meridional Transect Programme is an open ocean in situ observing system that will:

  • give early warning of any fundamental change in Atlantic ecosystem functionng
  • improve forecasts of the future ocean state and associated socio-economic impacts
  • provide a "contextual" logistical and scientific infrastructure for independently-funded national and international open ocean biogeochemical and ecological research.

The specific objectives are:

  • To collect hydrographic, chemical, ecological and optical data on transects between the UK and the Falkland Islands
  • To quantify the nature and causes of ecological and biogeochemical variability in planktonic ecosystems
  • To assess the effects of variability in planktonic ecosystems on biogenic export and on air-sea exchange of radiatively active gases

The measurements taken and experiments carried out on the AMT cruises will be closely linked to Themes 2 and 5. The planned cruise track also allows for the AMT data to be used in providing spatial context to the Sustained Observation Activities at the Porcupine Abyssal Plain Ocean Observatory (SO2) and the Western Channel Observatory (SO10).

More detailed information on this Work Package is available at pages 6 - 9 of the official Oceans 2025 Theme 10 document: Oceans 2025 Theme 10

Weblink: http://www.oceans2025.org/


Data Activity or Cruise Information

Data Activity

Start Date (yyyy-mm-dd) 2009-10-14
End Date (yyyy-mm-dd) 2009-10-14
Organization Undertaking ActivityPlymouth Marine Laboratory
Country of OrganizationGermany
Originator's Data Activity IdentifierJC039_CTD_CTD002S
Platform Categorylowered unmanned submersible

BODC Sample Metadata Report for JC039_CTD_CTD002S

Sample reference number Nominal collection volume(l) Bottle rosette position Bottle firing sequence number Minimum pressure sampled (dbar) Maximum pressure sampled (dbar) Depth of sampling point (m) Bottle type Sample quality flag Bottle reference Comments
228720   20.00 1 1  133.60  134.60  132.20 Niskin bottle No problem reported    
228721   20.00 2 2  103.40  104.40  102.20 Niskin bottle No problem reported    
228722   20.00 3 3   52.50   53.50   51.80 Niskin bottle No problem reported    
228723   20.00 4 4   52.60   53.60   51.90 Niskin bottle No problem reported    
228724   20.00 5 5   38.50   39.50   37.90 Niskin bottle No problem reported    
228725   20.00 6 6   38.60   39.60   38.00 Niskin bottle No problem reported    
228726   20.00 7 7   38.60   39.60   38.00 Niskin bottle No problem reported    
228727   20.00 8 8   21.80   22.80   21.40 Niskin bottle No problem reported    
228728   20.00 9 9   21.80   22.80   21.40 Niskin bottle No problem reported    
228729   20.00 10 10   19.30   20.30   18.90 Niskin bottle No problem reported    
228730   20.00 11 11   19.30   20.30   18.90 Niskin bottle No problem reported    
228731   20.00 12 12   16.40   17.40   16.00 Niskin bottle Bottle misfire    
228732   20.00 13 13   16.50   17.50   16.10 Niskin bottle No problem reported    
228733   20.00 14 14    9.40   10.40    9.10 Niskin bottle No problem reported    
228734   20.00 15 15    9.40   10.40    9.10 Niskin bottle No problem reported    
228735   20.00 16 16    4.00    5.00    3.70 Niskin bottle No problem reported    
228736   20.00 17 17    4.00    5.00    3.70 Niskin bottle No problem reported    
228737   20.00 18 18    1.70    2.70    1.40 Niskin bottle No problem reported    
228738   20.00 19 19    1.70    2.70    1.40 Niskin bottle No problem reported    
228739   20.00 20 20    1.60    2.60    1.30 Niskin bottle No problem reported    
228740   20.00 21 21    1.70    2.70    1.40 Niskin bottle No problem reported    
228741   20.00 22 22    1.70    2.70    1.40 Niskin bottle No problem reported    
228742   20.00 23 23    1.70    2.70    1.40 Niskin bottle No problem reported    
228743   20.00 24 24    1.70    2.70    1.40 Niskin bottle No problem reported    

Please note:the supplied parameters may not have been sampled from all the bottle firings described in the table above. Cross-match the Sample Reference Number above against the SAMPRFNM value in the data file to identify the relevant metadata.

Related Data Activity activities are detailed in Appendix 1

Cruise

Cruise Name JC039 (AMT19, JC040)
Departure Date 2009-10-13
Arrival Date 2009-12-01
Principal Scientist(s)Andrew Rees (Plymouth Marine Laboratory)
Ship RRS James Cook

Complete Cruise Metadata Report is available here


Fixed Station Information


No Fixed Station Information held for the Series


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification

Appendix 1: JC039_CTD_CTD002S

Related series for this Data Activity are presented in the table below. Further information can be found by following the appropriate links.

If you are interested in these series, please be aware we offer a multiple file download service. Should your credentials be insufficient for automatic download, the service also offers a referral to our Enquiries Officer who may be able to negotiate access.

Series IdentifierData CategoryStart date/timeStart positionCruise
1630085Water sample data2009-10-14 04:59:0049.567 N, 8.63352 WRRS James Cook JC039 (AMT19, JC040)
1889274Water sample data2009-10-14 04:59:0049.567 N, 8.63352 WRRS James Cook JC039 (AMT19, JC040)
2109825Water sample data2009-10-14 04:59:0049.567 N, 8.63352 WRRS James Cook JC039 (AMT19, JC040)