Metadata Report for BODC Series Reference Number 2219347


Metadata Summary

Data Description

Data Category Surface temp/sal
Instrument Type
NameCategories
WET Labs {Sea-Bird WETLabs} WETStar fluorometer  fluorometers
WET Labs {Sea-Bird WETLabs} C-Star transmissometer  transmissometers
Sea-Bird SBE 45 MicroTSG thermosalinograph  thermosalinographs; water temperature sensor; salinity sensor
Sea-Bird SBE 38 thermometer  water temperature sensor
Instrument Mounting research vessel
Originating Country United Kingdom
Originator Mr Darren Rayner
Originating Organization National Oceanography Centre, Southampton
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) RAPIDMOC
RAPID-AMOC
 

Data Identifiers

Originator's Identifier DY039_PRODQXF_SURF
BODC Series Reference 2219347
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 2015-10-17 07:34
End Time (yyyy-mm-dd hh:mm) 2015-12-01 11:46
Nominal Cycle Interval 60.0 seconds
 

Spatial Co-ordinates

Southernmost Latitude 23.04350 N ( 23° 2.6' N )
Northernmost Latitude 50.89933 N ( 50° 54.0' N )
Westernmost Longitude 77.35900 W ( 77° 21.5' W )
Easternmost Longitude 1.29067 W ( 1° 17.4' W )
Positional Uncertainty 0.0 to 0.01 n.miles
Minimum Sensor or Sampling Depth 5.5 m
Maximum Sensor or Sampling Depth 5.5 m
Minimum Sensor or Sampling Height -
Maximum Sensor or Sampling Height -
Sea Floor Depth -
Sea Floor Depth Source -
Sensor or Sampling Distribution Fixed common depth - All sensors are grouped effectively at the same depth which is effectively fixed for the duration of the series
Sensor or Sampling Depth Datum Approximate - Depth is only approximate
Sea Floor Depth Datum -
 

Parameters

BODC CODERankUnitsTitle
AADYAA011DaysDate (time from 00:00 01/01/1760 to 00:00 UT on day)
AAFDZZ011DaysTime (time between 00:00 UT and timestamp)
ACYCAA011DimensionlessSequence number
ALATGP011DegreesLatitude north relative to WGS84 by unspecified GPS system
ALONGP011DegreesLongitude east relative to WGS84 by unspecified GPS system
ATTNDR011per metreAttenuation (red light wavelength) per unit length of the water body by 25cm path length red light transmissometer
CNDCSG011Siemens per metreElectrical conductivity of the water body by thermosalinograph
CPHLUMTF1Milligrams per cubic metreConcentration of chlorophyll-a {chl-a CAS 479-61-8} per unit volume of the water body [particulate >unknown phase] by through-flow fluorometer plumbed into non-toxic supply and manufacturer's calibration applied
FVLTWS011VoltsRaw signal (voltage) of instrument output by linear-response chlorophyll fluorometer
POPTDR011PercentTransmittance (red light wavelength) per 25cm of the water body by 25cm path length red light transmissometer
PSALSG011DimensionlessPractical salinity of the water body by thermosalinograph and computation using UNESCO 1983 algorithm and calibration against independent measurements
TEMPHG011Degrees CelsiusTemperature of the water body by thermosalinograph hull sensor and verification against independent measurements
TEMPHU011Degrees CelsiusTemperature of the water body by thermosalinograph hull sensor and no verification against independent measurements
TMESSG011Degrees CelsiusTemperature of electrical conductivity measurement by thermosalinograph
TVLTDR011VoltsRaw signal (voltage) of instrument output by 25cm path length red light transmissometer

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database

RRS Discovery cruise DY039 surface hydrography quality control report

Transmittance

Transmittance channel is very poor with over 50% of the dataset flagged. Periods where the non-toxic supply has been switched off for cleaning and spiking from sensor malfunction were also flagged.(BODC assessment)

Fluorescence

There is a steady increase in fluorescence from approximately 07:00:00 11/11/2015 until the non-toxic is turned off and cleaned approaching Nassau. (BODC assessment)


Data Access Policy

Open Data

These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.

If the Information Provider does not provide a specific attribution statement, or if you are using Information from several Information Providers and multiple attributions are not practical in your product or application, you may consider using the following:

"Contains public sector information licensed under the Open Government Licence v1.0."


Narrative Documents

RRS Discovery DY039 Underway Cruise Document

Cruise details

Dates 17th October 2015 - 1st December 2015 (UTC)
Principal Scientific Officer Darren Rayner (National Oceanography Centre Southampton)

SeaBird Digital Oceanographic Thermometer SBE38

The SBE38 is an ultra-stable thermistor that can be integrated as a remote temperature sensor with an SBE21 Thermosalinograph or an SBE 45 Micro TSG, or as a secondary temperature sensor with an SBE 16 plus, 16plus-IM, 16plus V2, 16plus-IM V2 or 19plus V2 SEACAT CTD.

Temperature is determined by applying an AC excitation to reference resistances and an ultra-stable aged thermistor. The reference resistor is a hermetically sealed VISHAY. AC excitation and ratiometric comparison using a common processing channel removes measurement errors due to parasitic thermocouples, offset voltages, leakage currents and gain errors.

The SBE38 can operate in polled sampling, where it takes one sample and transmits the data, or in continuous sampling.

Specifications

Depth rating up to 10500 m
Temperature range -5 to 35°C
Initial accuracy ± 0.001°C
Resolution 0.00025°C
Stability 0.001°C in 6 months
Response time 500 ms
Self-heating error < 200 µK

Further details can be found in the manufacturer's specification sheet.

WET Labs WETStar Fluorometers

WET Labs WETStar fluorometers are miniature flow-through fluorometers, designed to measure relative concentrations of chlorophyll, CDOM, uranine, rhodamineWT dye, or phycoerythrin pigment in a sample of water. The sample is pumped through a quartz tube, and excited by a light source tuned to the fluorescence characteristics of the object substance. A photodiode detector measures the portion of the excitation energy that is emitted as fluorescence.

Specifications

By model:

  Chlorophyll WETStar CDOM WETStar Uranine WETStar Rhodamine WETStar Phycoerythrin WETStar
Excitation wavelength 460 nm 370 nm 485 nm 470 nm 525 nm
Emission wavelength 695 nm 460 nm 530 nm 590 nm 575 nm
Sensitivity 0.03 µg l-1 0.100 ppb QSD 1 µg l-1 - -
Range 0.03-75 µg l-1 0-100 ppb; 0-250 ppb 0-4000 µg l-1 - -

All models:

Temperature range 0-30°C
Depth rating 600 m
Response time 0.17 s analogue; 0.125 s digital
Output 0-5 VDC analogue; 0-4095 counts digital

Further details can be found in the manufacturer's specification sheet, and in the instrument manual.

WETLabs C-Star transmissometer

This instrument is designed to measure beam transmittance by submersion or with an optional flow tube for pumped applications. It can be used in profiles, moorings or as part of an underway system.

Two models are available, a 25 cm pathlength, which can be built in aluminum or co-polymer, and a 10 cm pathlength with a plastic housing. Both have an analog output, but a digital model is also available.

This instrument has been updated to provide a high resolution RS232 data output, while maintaining the same design and characteristics.

Specifications

Pathlength 10 or 25 cm
Wavelength 370, 470, 530 or 660 nm
Bandwidth

~ 20 nm for wavelengths of 470, 530 and 660 nm

~ 10 to 12 nm for a wavelength of 370 nm

Temperature error 0.02 % full scale °C-1
Temperature range 0 to 30°C
Rated depth

600 m (plastic housing)

6000 m (aluminum housing)

Further details are available in the manufacturer's specification sheet or user guide.

RRS Discovery cruise DY039 surface hydrography instrumentation

Instrumentation

The sea surface hydrographical suite of sensors was fed by the pumped-seawater, non-toxic supply. The depth of the seawater intake was at 5.5 m.

The following surface hydrology sensors were fitted:

Manufacturer Model Serial number Last manufacturer's
calibration date
Comments
WETLabs Fluorimeter WETStar WS3S-246 01/09/2015  
WETLabs Transmissometer C-Star CST-112R 26/06/2015 25 cm pathlength
Sea-Bird Temperature sensor SBE38 3854115-0491 25/06/2015  
Sea-Bird SBE45 TSG 4548881-0229 13/08/2015  

SeaBird MicroTSG Thermosalinograph SBE 45

The SBE45 MicroTSG is an externally powered instrument designed for shipboard measurement of temperature and conductivity of pumped near-surface water samples. The instrument can also compute salinity and sound velocity internally.

The MicroTSG comprises a platinum-electrode glass conductivity cell and a stable, pressure-protected thermistor temperature sensor. It also contains an RS-232 port for appending the output of a remote temperature sensor, allowing for direct measurement of sea surface temperature.

The instrument can operate in Polled, Autonomous and Serial Line Sync sampling modes:

  • Polled sampling: the instrument takes one sample on command
  • Autonomous sampling: the instrument samples at preprogrammed intervals and does not enter quiescence (sleep) state between samples
  • Serial Line Sync: a pulse on the serial line causes the instrument to wake up, sample and re-enter quiescent state automatically

Specifications

  Conductivity Temperature Salinity
Range 0 to 7 Sm-1 -5 to 35°C  
Initial accuracy 0.0003 Sm-1 0.002°C 0.005 (typical)
Resolution 0.00001 Sm-1 0.0001°C 0.0002 (typical)
Typical stability (per month) 0.0003 Sm-1 0.0002°C 0.003 (typical)

Further details can be found in the manufacturer's specification sheet.

RRS Discovery cruise DY039 surface hydrography data processing procedures

Originator's Data Processing

Thermosalinograph (TSG, SurfTSG)

The TSG stream contains the logged temperatures, conductivity, and derived salinity from the TSG. The salinity values were recalculated from the housing temperature and conductivity (using mtsg_make_sal.m) to confirm that the salinity values stored in the files was reliable and the conductivity units (S/m) as reported in the netCDF attributes.

Calibration of TSG salinity used the followed steps:

Bottle salinity files of the name tsg_dy039_NNN.csv (where NNN refers to the incremental crate number) were created from the Autosal output files with the addition of a time variable of the form JJJHHMMSS, referring to Julian day, hour, minute and seconds that each sample was gathered at. Standards were run infrequently prior to CTD station 10 but run before and after each crate thereafter. Each standard was given an incremental number consistent with the time of its running with respect to the other standards run during the cruise.

These data were ingested into Mstar format using mtsg_01. This program requires input of adjustment to be applied, if there is salinometer drift, and bath temperature. It creates a file tsg_dy039_NNN.nc and a file tsg_dy039_all.nc, which is an appended file of all the individual files.

To merge and compare the bottle samples with the salinity, the programs mtsg_medav_clean_cal, which creates a 1Dminute average, and mtsg_bottle_compare, which extracts the underway data corresponding to each bottle were run.

Following the change of sensor near Tenerife, the sensor behaved admirably and the residuals were contained in an envelope of ±0.005. A number of wayward points are evident around Julian day 307 and 313. These are believed to be bad salinometer bottles similar to those noted during the CTD processing. No further calibration was applied to the sensor.

The Mstar Thermosalinograph files provided to BODC were used for BODC processing. Data were additionally logged into the RVS Level-C format files and TECHSAS which have been archived at BODC.

Files delivered to BODC

Filename Content description Format Interval Start date/time (UTC) End date/time (UTC) Comments
met_tsg_dy039_01_calib.nc Fluorescence and transmittance, housing temperature, remote temperature, salinity and conductivity Mstar 1 sec. 17/10/2015 14:04:40 01/12/2015 12:40:44  

BODC Data Processing

The files were reformatted to BODC internal format using standard data banking procedures. All files were averaged to 60 second intervals. The following table shows how the variables within the files were mapped to appropriate BODC parameter codes:

met_tsg_dy039_01_calib.nc

Originator's variable Originator's units Description BODC Code BODC Units Unit conversion Comments
trans volts Raw voltage measured by transmissometer TVLTDR01 volts none  
fluo volt Raw voltage measured by fluorometer FVLTWS01 volt none  
time seconds since 01/01/2015 Measure timestamp       Not transferred
psal pss-78 TSG salinity calibrated PSALSG01 dimensionless none
temp_h degrees celcius Housing water temperature TMESSG01 degrees celcius none  
cond s/m Not transferred
cond_cal s/m Conductivity CNDCSG01 s/m none  
temp_m degrees celcius Remote water temperature TEMPHU01 degrees celcius none  
temp_m_cal degrees celcius Remote water temperature TEMPHG01 degrees celcius none Calibrated against CTD by originator's.

All the reformatted data were visualised using the in-house EDSERPLO software. Suspect data were marked by adding an appropriate quality control flag.

Calibration

Field Calibrations

Salinity was calibrated as described in the originators processing section above.

Manufacturers Calibrations

Transmissometer

The transmissometer voltage channel was converted to beam transmission ( beamtrans ) and beam attenuation ( atten ) as follows:

beamtrans [%] = ([ volts - Vdark ] / [ Vref - Vdark ])100

atten [per m] = (-1/ pathlength ) ln( beamtrans /100)

where Vdark = 0.058 V, Vref = 4.623 V and pathlength = 0.25 m.

Fluorometer

The fluorescence voltage channel was converted to engineering units ( chla ) using the following calibration:

chla [µg/L]= SF ( volts - CWO )

where SF = 14.5 µg/L/V and CWO = 0.053 V.


Project Information

Monitoring the Meridional Overturning Circulation at 26.5N (RAPIDMOC)

Scientific Rationale

There is a northward transport of heat throughout the Atlantic, reaching a maximum of 1.3PW (25% of the global heat flux) around 24.5°N. The heat transport is a balance of the northward flux of a warm Gulf Stream, and a southward flux of cooler thermocline and cold North Atlantic Deep Water that is known as the meridional overturning circulation (MOC). As a consequence of the MOC northwest Europe enjoys a mild climate for its latitude: however abrupt rearrangement of the Atlantic Circulation has been shown in climate models and in palaeoclimate records to be responsible for a cooling of European climate of between 5-10°C. A principal objective of the RAPID programme is the development of a pre-operational prototype system that will continuously observe the strength and structure of the MOC. An initiative has been formed to fulfill this objective and consists of three interlinked projects:

  • A mooring array spanning the Atlantic at 26.5°N to measure the southward branch of the MOC (Hirschi et al., 2003 and Baehr et al., 2004).
  • Additional moorings deployed in the western boundary along 26.5°N (by Prof. Bill Johns, University of Miami - project MOCHA) to resolve transport in the Deep Western Boundary Current (Bryden et al., 2005). These moorings allow surface-to-bottom density profiles along the western boundary, Mid-Atlantic Ridge, and eastern boundary to be observed. As a result, the transatlantic pressure gradient can be continuously measured.
  • Monitoring of the northward branch of the MOC using submarine telephone cables in the Florida Straits (Baringer et al., 2001) led by Dr Molly Baringer (NOAA/AOML/PHOD) - Western Boundary Time Series (WBTS) project.

The UK-led monitoring array system was recovered and redeployed annually until 2008 under RAPID funding. From 2008 until 2015 the array continued to be serviced annually under RAPID-WATCH funding. From 2015 until 2021 the array was serviced under RAPID-AMOC funding. Since 2022 the servicing of the array has continued to be funded by the Natural Environment Research Council (NERC). The US-led projects are funded by the National Science Foundation (NSF) (MOCHA project) and NOAA Office of Climate Observations (WBTS project).

The array will be focussed on three regions, the Eastern Boundary (EB), the Mid Atlantic Ridge (MAR) and the Western Boundary (WB). The geographical extent of these regions are as follows:

  • Eastern Boundary (EB) array defined as a box with the south-east corner at 23.5°N, 25.5°W and the north-west corner at 29.0°N, 12.0°W
  • Mid Atlantic Ridge (MAR) array defined as a box with the south-east corner at 23.0°N, 52.1°W and the north-west corner at 26.5°N, 40.0°W
  • Western Boundary (WB) array defined as a box with the south-east corner at 26.0°N, 77.5°W and the north-west corner at 27.5°N, 69.5°W

References

Baehr, J., Hirschi, J., Beismann, J.O. and Marotzke, J. (2004) Monitoring the meridional overturning circulation in the North Atlantic: A model-based array design study. Journal of Marine Research, Volume 62, No 3, pp 283-312.

Baringer, M.O'N. and Larsen, J.C. (2001) Sixteen years of Florida Current transport at 27N Geophysical Research Letters, Volume 28, No 16, pp3179-3182

Bryden, H.L., Johns, W.E. and Saunders, P.M. (2005) Deep Western Boundary Current East of Abaco: Mean structure and transport. Journal of Marine Research, Volume 63, No 1, pp 35-57.

Hirschi, J., Baehr, J., Marotzke J., Stark J., Cunningham S.A. and Beismann J.O. (2003) A monitoring design for the Atlantic meridional overturning circulation. Geophysical Research Letters, Volume 30, No 7, article number 1413 (DOI 10.1029/2002GL016776)


RAPID Climate Change - Atlantic Meridional Overturning Circulation (RAPID-AMOC)

RAPID-AMOC is an £8.4 million, 7 year (2013-2020) research programme that builds on the success of the Natural Environment Research Council's (NERC) RAPID and RAPID-WATCH programmes and will deliver a 16 year long time series of the Atlantic Meridional Overturning Circulation (AMOC).

Background

The Atlantic Meridional Overturning Circulation (AMOC) is a critical element in the energy balance of the global climate system. The AMOC consists of a near-surface, warm northward flow of ocean water, compensated by a colder southward return flow at depth. This heat is transferred from the ocean to the atmosphere at mid-latitudes, with a substantial impact on climate and, in particular, on that of the UK and northwest Europe.

Observing and understanding changes in the AMOC is critically important for identifying the mechanisms of decadal climate variability and change, and for interannual-to-decadal climate prediction. This includes predicting changes in the location, frequency and intensity of Atlantic hurricanes, storms in the North Atlantic and over Europe, shifts in tropical and European precipitation patterns, and the response of sea level to changing radiative forcing. Sustained observations are also critical for assessing the possibility of abrupt change in the AMOC that are known to occur in palaeoclimatic records.

Since 2004 the NERC RAPID and RAPID-WATCH programmes, in partnership with the National Science Foundation and the National Oceanic and Atmospheric Administration in the US, have supported an observing system to continuously measure the AMOC at 26.5°N via a trans-basin array of moored instruments. This measures the basin-wide strength and vertical structure of the AMOC, and its components.

Observations from the array have already revolutionised understanding of AMOC variability and documented its variability on seasonal to interannual timescales. The first few years of observations, demonstrated the feasibility of AMOC measurement, provided new insights into the seasonal cycle, and allowed apparent trends in previous historical 'snapshots' to be seen in the context of natural variability. RAPID-AMOC will extend the AMOC time series.

Objective

RAPID-AMOC's overall objective is to determine the variability of the AMOC, and its links to climate and to the ocean carbon sink, on interannual-to-decadal time scales

This will be achieved by the continued support of the monitoring array and supporting the use of the data in three key areas:

  • Application of array data for improved ocean state estimation;
  • Use of array data to understand the role of the AMOC in climate variability and predictability;
  • Addition of biogeochemical sensors to the array and use to constrain biogeochemical fluxes.

Three projects have been funded to address the objectives of RAPID-AMOC:

  • Reanalysis of the AMOC
  • DYNamics and predictability of the Atlantic Meridional Overturning and Climate (DYNAMOC)
  • Atlantic BiogeoChemical fluxes (ABC Fluxes)

Data Activity or Cruise Information

Cruise

Cruise Name DY039
Departure Date 2015-10-17
Arrival Date 2015-12-01
Principal Scientist(s)Darren Rayner (National Oceanography Centre, Southampton)
Ship RRS Discovery

Complete Cruise Metadata Report is available here


Fixed Station Information


No Fixed Station Information held for the Series


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification