Metadata Report for BODC Series Reference Number 2309305
Metadata Summary
Problem Reports
Data Access Policy
Narrative Documents
Project Information
Data Activity or Cruise Information
Fixed Station Information
BODC Quality Flags
SeaDataNet Quality Flags
Metadata Summary
Data Description |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
Data Identifiers |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
Time Co-ordinates(UT) |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
Spatial Co-ordinates | |||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
Parameters |
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||||||||
Problem Reports
No Problem Report Found in the Database
Data Access Policy
Open Data
These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.
If the Information Provider does not provide a specific attribution statement, or if you are using Information from several Information Providers and multiple attributions are not practical in your product or application, you may consider using the following:
"Contains public sector information licensed under the Open Government Licence v1.0."
Narrative Documents
Perkin Elmer 2400 Series II CHNSO Elemental Analyser
Basic Information
The PerkinElmer 2400 Series II CHNS/O Elemental Analyzer (2400 Series II) is an instrument for the determination of carbon, hydrogen, nitrogen, sulfur or oxygen content in organic and other types of materials. It has the capability of handling a wide variety of sample types.
The 2400 Series II CHNS/O Elemental Analyzer is capable of operating in three modes: CHN, CHNS and Oxygen, is fully automated, and includes a 60 position autosampler. The analyser has an accuracy of <=0.3% and a precision of <=02%. The analytical range is from 0.001 -3.6 mgs for C, 0.001-1.0 for H, 0.001-6 mgs for N and 0.001 to 2.0 mgs for S and O.
Instrument Specification
| Performance | |
|---|---|
| Accuracy | <=0.3% |
| Precision | <=0.2% |
| Analysis Times | |
| CHN | 6 mins |
| CHNS | 8 mins |
| Oxygen | 4 mins |
| Sample Size | |
| Range | 0-500 mg |
| Analytical Range | |
| C | 0.001-3.6 mgs |
| H | 0.001-1.0 mgs |
| N | 0.001-6.0 mgs |
| S | 0.001-2.0 mgs |
| O | 0.001-2.0 mgs |
| Site Requirements | |
| Dimensions (HxWxD) | 61 cm x 55 cm x 55 cm |
| Weight | 45 kg |
| Power Requirements | 100-230 VAC |
More information
More information can be found in the brochure.
Non-toxic (underway) sea water supply
A source of uncontaminated near-surface (commonly 3 to 7 m) seawater pumped continuously to shipboard laboratories on research vessels. There is typically a temperature sensor near the intake (known as the hull temperature) to provide measurements that are as close as possible to the ambient water temperature. The flow from the supply is typically directed through continuously logged sensors such as a thermosalinograph and a fluorometer. Water samples are often collected from the non-toxic supply. The system is also referred to as the underway supply.
POC, PIC, PON, BSi and coccolith enumeration from cruise JR16001
Originator's Protocol for Data Acquisition and Analysis
Introduction
The RRS James Clark Ross cruise JR16001 was undertaken as AMT 26 as part of the Oceans 2025 project in a transect across the Atlantic Ocean between 20 September 2016 to 05 November 2016.
A series of CTD and underway samples were collected for analysis of particulate organic carbon (POC), particulate inorganic carbon (PIC), coccolith enumeration (cell counts) and biogenic silica concentration (BSi). The purpose of these samples was to provide an assessment of the inorganic and organic particle concentrations in surface water, provide indices of community composition, and analytical means to calibrate satellite PIC algorithms.
Underway Sampling methodology
Discrete underway samples were collected from the ship's Surf-Met (underway surface and meteorological data collection) flow system in the prep lab 3 to 4 times per day.
Analytical methodology
PIC samples were collected on 0.4 μm polycarbonate filters, rinsed with potassium tetraborate buffer, dried and stored in metal free centrifuge tubes. These were analysed by ICP-OES for particulate calcium.
Coccolith and cell counts were collected on 0.45 μm Millipore HA (nitrocellulose) filters, rinsed with potassium tetraborate buffer, frozen at 20°C, dried, then mounted onto slides using Norland Optical Adhesive and enumerated by birefringence microscopy.
Biogenic silica (BSi) samples were filtered onto 0.4 μm polycarbonate filters, dried in clean centrifuge tubes, and will be analysed following the protocol of Brzezinski and Nelson (1989).
POC samples were filtered onto pre-combusted glass fibre filters, rinsed with 0.2 μm filtered seawater, dried and subsequently fumed with concentrated HCl to remove inorganic carbon. They were analysed post-cruise at Bigelow Analytical Services.
Blanks for filtered samples were collected twice weekly.
References Cited
Brzezinski, M.A., Nelson, D.M., 1989. Seasonal changes in the silicon cycle within a Gulf Stream warm-core ring. Deep Sea Research Part A. Oceanographic Research Papers, 36(7), 1009-1030.
JR16001 Cruise report
Further information can be found in the JR16001 Cruise report.
BODC Data Processing Procedures
Data received were loaded into the BODC database using established BODC data banking procedures. A parameter mapping table is provided below:
| Originator's Variable | Originator's Units | BODC Parameter Code | BODC Unit | Comments |
|---|---|---|---|---|
| PIC | mol m-3 | CINGFA04 | umol/l | Conversion of *1000 was applied to the data |
| POC | mg m-3 | CORGCAP1 | umol/l | Conversion of *1/12 was applied to data |
| PON | mg m-3 | NTOTCAP1 | umol/l | Conversion of *1/14 was applied to data |
| BSi | mmol m-3 | OPALWCP4 | umol/l | None as these are equivalent units. |
| Quads | #/ml | ABD07078 | #/ml | None as these are equivalent units. |
| PCCA | #/ml | ABD07070 | #/ml | None as these are equivalent units. |
Project Information
PML National Capability
The Plymouth Marine Laboratory National Capability focuses on long term science concerned with basin/decadal variability of the Ocean.
Data Activity or Cruise Information
Cruise
| Cruise Name | JR16001 (AMT26) |
| Departure Date | 2016-09-20 |
| Arrival Date | 2016-11-04 |
| Principal Scientist(s) | Andrew P Rees (Plymouth Marine Laboratory) |
| Ship | RRS James Clark Ross |
Complete Cruise Metadata Report is available here
Fixed Station Information
No Fixed Station Information held for the Series
BODC Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
| Flag | Description |
|---|---|
| Blank | Unqualified |
| < | Below detection limit |
| > | In excess of quoted value |
| A | Taxonomic flag for affinis (aff.) |
| B | Beginning of CTD Down/Up Cast |
| C | Taxonomic flag for confer (cf.) |
| D | Thermometric depth |
| E | End of CTD Down/Up Cast |
| G | Non-taxonomic biological characteristic uncertainty |
| H | Extrapolated value |
| I | Taxonomic flag for single species (sp.) |
| K | Improbable value - unknown quality control source |
| L | Improbable value - originator's quality control |
| M | Improbable value - BODC quality control |
| N | Null value |
| O | Improbable value - user quality control |
| P | Trace/calm |
| Q | Indeterminate |
| R | Replacement value |
| S | Estimated value |
| T | Interpolated value |
| U | Uncalibrated |
| W | Control value |
| X | Excessive difference |
SeaDataNet Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
| Flag | Description |
|---|---|
| 0 | no quality control |
| 1 | good value |
| 2 | probably good value |
| 3 | probably bad value |
| 4 | bad value |
| 5 | changed value |
| 6 | value below detection |
| 7 | value in excess |
| 8 | interpolated value |
| 9 | missing value |
| A | value phenomenon uncertain |
| B | nominal value |
| Q | value below limit of quantification |