Search the data

Metadata Report for BODC Series Reference Number 297190


Metadata Summary

Data Description

Data Category CTD or STD cast
Instrument Type
NameCategories
Bissett-Bermann 9040 CTD system  CTD; water temperature sensor; salinity sensor
Instrument Mounting research vessel
Originating Country United Kingdom
Originator -
Originating Organization National Institute of Oceanography (now National Oceanography Centre, Southampton)
Processing Status QC in progress
Online delivery of data Download not available
Project(s) -
 

Data Identifiers

Originator's Identifier HVDDI0770903
BODC Series Reference 297190
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 1971-04-25 21:02
End Time (yyyy-mm-dd hh:mm) -
Nominal Cycle Interval -
 

Spatial Co-ordinates

Latitude 60.00670 N ( 60° 0.4' N )
Longitude 19.98670 W ( 19° 59.2' W )
Positional Uncertainty Unspecified
Minimum Sensor or Sampling Depth 0.0 m
Maximum Sensor or Sampling Depth 2018.81 m
Minimum Sensor or Sampling Height -
Maximum Sensor or Sampling Height -
Sea Floor Depth -
Sea Floor Depth Source -
Sensor or Sampling Distribution Variable common depth - All sensors are grouped effectively at the same depth, but this depth varies significantly during the series
Sensor or Sampling Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
Sea Floor Depth Datum -
 

Parameters

BODC CODERankUnitsTitle
PRESPR011DecibarsPressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level
PSALPR011DimensionlessPractical salinity of the water body by conductivity cell and computation using UNESCO 1983 algorithm
TEMPST011Degrees CelsiusTemperature of the water body by CTD or STD

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database


Data Access Policy

Public domain data

These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.

The recommended acknowledgment is

"This study uses data from the data source/organisation/programme, provided by the British Oceanographic Data Centre and funded by the funding body."


Narrative Documents

Bissett-Bermann 9040 Conductivity Temperature and Depth

The basic configuration of the B-B 9040 CTD incorporates pressure, temperature and conductivity sensors which could be logged digitally. This system also made it possible to derive other parameters, such as salinity, depth and sound velocity.

The instrument was versatile and it was possible to attach a dissolved oxygen sensor or to change the CTD housing, allowing it to obtain data from deeper layers in the water column. The accuracy for salinity is ±0.02 ppt , and ±0.02°C for temperature.

This instrument was also known as the Plessey 9040.


Project Information


No Project Information held for the Series

Data Activity or Cruise Information

Cruise

Cruise Name D39
Departure Date 1971-04-21
Arrival Date 1971-06-07
Principal Scientist(s)Peter Foxton (National Institute of Oceanography)
Ship RRS Discovery

Complete Cruise Metadata Report is available here


Fixed Station Information


No Fixed Station Information held for the Series


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification