Search the data

Metadata Report for BODC Series Reference Number 34033


Metadata Summary

Data Description

Data Category Offshore sea floor pressure series
Instrument Type
NameCategories
Teleost Pressure Recorder  sea level recorders; water temperature sensor
Instrument Mounting fixed benthic node
Originating Country United Kingdom
Originator -
Originating Organization Institute of Oceanographic Sciences Bidston Laboratory (now National Oceanography Centre, Liverpool)
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) IOS North Channel Experiment 1979
 

Data Identifiers

Originator's Identifier 793/979/218
BODC Series Reference 34033
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 1979-08-06 21:22
End Time (yyyy-mm-dd hh:mm) 1979-09-23 15:07
Nominal Cycle Interval 900.0 seconds
 

Spatial Co-ordinates

Latitude 55.46330 N ( 55° 27.8' N )
Longitude 6.16330 W ( 6° 9.8' W )
Positional Uncertainty 0.1 to 0.5 n.miles
Minimum Sensor or Sampling Depth 108.0 m
Maximum Sensor or Sampling Depth 108.0 m
Minimum Sensor or Sampling Height 0.0 m
Maximum Sensor or Sampling Height 0.0 m
Sea Floor Depth 108.0 m
Sea Floor Depth Source -
Sensor or Sampling Distribution Fixed common depth - All sensors are grouped effectively at the same depth which is effectively fixed for the duration of the series
Sensor or Sampling Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
Sea Floor Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
 

Parameters

BODC CODERankUnitsTitle
AADYAA011DaysDate (time from 00:00 01/01/1760 to 00:00 UT on day)
AAFDZZ011DaysTime (time between 00:00 UT and timestamp)
PRSTPS011DecibarsPressure (measured variable) exerted by the water body plus atmosphere by fixed in-situ pressure sensor

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database


Data Access Policy

Open Data

These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.

If the Information Provider does not provide a specific attribution statement, or if you are using Information from several Information Providers and multiple attributions are not practical in your product or application, you may consider using the following:

"Contains public sector information licensed under the Open Government Licence v1.0."


Narrative Documents

Teleost Pressure Recorder

This instrument was developed at I.O.S. Bidston. Each recorder consists of a Bell and Howell strain gauge or a Digiquartz pressure transducer. The strain gauge sensor uses a Bell and Howell type 4-306 transducer and operates as a phase shift oscillator whose frequency is controlled by the ratio of output to input voltage of the transducer Wheatstone bridge network. The quartz crystal pressure sensor consists of a convoluted bellows linked to a 40kHz quartz crystal resonator coupled by piezoelectric action to an electronic resonator.

The pressure and temperature recorder consists of an Aanderaa current meter type logger modified to accept input from a pressure sensor containing a Bell and Howell strain gauge or a Digiquartz pressure transducer and a platinum resistance thermometer.

The pressure and temperature transducers are mounted in the same heat sink for compatible data. The pressure sensors are mounted in a protective frame of dimensions 1.75m by 1.14m by 0.66m, attached to a ballast plate or frame. Teleost recorders are deployed as pop-up moorings and released from their ballast frames by firing a pyrotechnic release by acoustic command.

IOS Calibration and Data Processing of Off-Shore Tide Gauge Data

Calibration of pressure/frequency sensors and thermistors are carried out using the facilities and staff at I.O.S. Bidston with the exception of pre 1975 pressure/frequency sensors, which were calibrated in the pressure chamber at I.O.S. Wormley.

The data are copied from the logger magnetic tape to 9 track magnetic tape and disk. The data are either listed or plotted as an initial check. A program is then used to check the data from the temperature sensor channels, calculate and plot the temperature values and store them (if temperature sensor channels are available).

A second program performs a similar function for the pressure sensor channel, using the pressure frequency coefficient to convert each pressure frequency to the frequency at the reference temperature and calculating the pressures using the pressure frequency calibration. The data values, generally at 15 minute intervals, but occasionally at 10 minute intervals, of pressure are then plotted and stored. If waterhead is required, it may be computed by subtracting atmospheric pressure and applying the hydrostatic relation:-

H = P / ( d * g )
H = waterhead (cm)
P = pressure (0.01 mb)
d = density (kg/m3)
g = gravitational acceleration (m/s2)

Station E (North Channel) Data Processing Notes

Clock gained 3 seconds over 62 days, 8.25 hours; the cycle interval and time values have been corrected.

Instrument characteristics and calibration factors

Teleost Pressure Recorder, sensor DIG, serial number 280
Original sampling interval 15 minutes
Integration period 900 s
Temperature coefficient -0.927 Hz/°C
Pressure sensitivity at 9.647°C 0.183 Hz/mb

To convert pressure to elevation the following values should be used:

Density (from CTD casts) 1026.05 kg/m3
Gravitational acceleration constant 9.815 m/s2

A current meter was deployed on this rig, 6m above the tide gauge.


Project Information

IOS North Channel Experiment 1979

This experiment was conducted by I.O.S. Bidston in the North Channel of the Irish Sea, during August and September 1979, in order to study the tidal and non-tidal dynamics of the region.

Currents were measured at eight stations, sea bed pressures were measured at three stations and coastal tide gauges installed to measure sea surface elevations at four sites.

A density survey of the area was carried out by continuously monitoring sea surface temperature and sea water conductivity, and by taking profiles of temperature and conductivity with depth.


Data Activity or Cruise Information


No Data Activity or Cruise Information held for the Series


Fixed Station Information


No Fixed Station Information held for the Series


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification