Metadata Report for BODC Series Reference Number 36851
Metadata Summary
Problem Reports
Data Access Policy
Narrative Documents
Project Information
Data Activity or Cruise Information
Fixed Station Information
BODC Quality Flags
SeaDataNet Quality Flags
Metadata Summary
Data Description |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Data Identifiers |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Time Co-ordinates(UT) |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Spatial Co-ordinates | |||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Parameters |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
Problem Reports
No Problem Report Found in the Database
Data Access Policy
Open Data
These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.
If the Information Provider does not provide a specific attribution statement, or if you are using Information from several Information Providers and multiple attributions are not practical in your product or application, you may consider using the following:
"Contains public sector information licensed under the Open Government Licence v1.0."
Narrative Documents
Teleost Pressure Recorder
This instrument was developed at I.O.S. Bidston. Each recorder consists of a Bell and Howell strain gauge or a Digiquartz pressure transducer. The strain gauge sensor uses a Bell and Howell type 4-306 transducer and operates as a phase shift oscillator whose frequency is controlled by the ratio of output to input voltage of the transducer Wheatstone bridge network. The quartz crystal pressure sensor consists of a convoluted bellows linked to a 40kHz quartz crystal resonator coupled by piezoelectric action to an electronic resonator.
The pressure and temperature recorder consists of an Aanderaa current meter type logger modified to accept input from a pressure sensor containing a Bell and Howell strain gauge or a Digiquartz pressure transducer and a platinum resistance thermometer.
The pressure and temperature transducers are mounted in the same heat sink for compatible data. The pressure sensors are mounted in a protective frame of dimensions 1.75m by 1.14m by 0.66m, attached to a ballast plate or frame. Teleost recorders are deployed as pop-up moorings and released from their ballast frames by firing a pyrotechnic release by acoustic command.
Data Processing Notes
Instrument integrates over 15 minutes at end of which data is logged. Clock gained 17 seconds over 108 days 19 hours 14 minutes 43 seconds; the original cycle interval and time values have been corrected.
Instrument Characteristics
Station | A6 |
---|---|
Teleost sensor | 283/4 |
BODC Series Ref. | 36851 |
Nominal sampling interval | 900secs |
Integration period | 900secs |
Actual sampling interval | 14.999973mins |
IOS Data Processing of Off-Shore Pressure Recorder Data
Data processing consists of two stages:-
-
Pressures have been sample rate reduced from the basic time step of the recorder to produce the hourly values and have been interpolated by a cubic spline to generate the value on cardinal hours.
-
Instrumental drift has been removed and the drift free series is produced with an artificial mean value, usually of 100mbar.
Project Information
No Project Information held for the Series
Data Activity or Cruise Information
No Data Activity or Cruise Information held for the Series
Fixed Station Information
No Fixed Station Information held for the Series
BODC Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
Blank | Unqualified |
< | Below detection limit |
> | In excess of quoted value |
A | Taxonomic flag for affinis (aff.) |
B | Beginning of CTD Down/Up Cast |
C | Taxonomic flag for confer (cf.) |
D | Thermometric depth |
E | End of CTD Down/Up Cast |
G | Non-taxonomic biological characteristic uncertainty |
H | Extrapolated value |
I | Taxonomic flag for single species (sp.) |
K | Improbable value - unknown quality control source |
L | Improbable value - originator's quality control |
M | Improbable value - BODC quality control |
N | Null value |
O | Improbable value - user quality control |
P | Trace/calm |
Q | Indeterminate |
R | Replacement value |
S | Estimated value |
T | Interpolated value |
U | Uncalibrated |
W | Control value |
X | Excessive difference |
SeaDataNet Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
0 | no quality control |
1 | good value |
2 | probably good value |
3 | probably bad value |
4 | bad value |
5 | changed value |
6 | value below detection |
7 | value in excess |
8 | interpolated value |
9 | missing value |
A | value phenomenon uncertain |
B | nominal value |
Q | value below limit of quantification |