Metadata Report for BODC Series Reference Number 40966
Metadata Summary
Problem Reports
Data Access Policy
Narrative Documents
Project Information
Data Activity or Cruise Information
Fixed Station Information
BODC Quality Flags
SeaDataNet Quality Flags
Metadata Summary
Data Description |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Data Identifiers |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Time Co-ordinates(UT) |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Spatial Co-ordinates | |||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Parameters |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
Problem Reports
No Problem Report Found in the Database
Data Access Policy
Open Data
These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.
If the Information Provider does not provide a specific attribution statement, or if you are using Information from several Information Providers and multiple attributions are not practical in your product or application, you may consider using the following:
"Contains public sector information licensed under the Open Government Licence v1.0."
Narrative Documents
Aanderaa Pressure Recorder Type TG-2A and WLR-5
Pressure recorder TG-2A (serial number 64) was used until the end of 1979. It was then returned to Aanderaa Instruments Limited who carried out modifications changing it to the specification of an Aanderaa WLR-5. Hence from 1980 onwards the instrument is known as Aanderaa WLR-5 (serial number 500).
The Aanderaa recorder uses a Digiquartz type 2-300a quartz crystal pressure transducer. The pressure sensor consists of a convoluted bellows linked to a 40kHz quartz crystal resonator coupled by piezoelectric action to an electronic resonator. The sensor pack is mounted in a low profile steel tripod frame 0.76m by 1.183m in size with the sensor level approximately 0.48m above the frame base. Data are recorded on to 0.25 inch magnetic tape on an Aanderaa data logger in the same case. A quartz crystal clock is used for controlling the sampling interval.
The data are recorded as 10 bit binary words in serial form with the frequency count from the sensor stored as the most and least significant counts. There is no temperature sensor. The tide gauge is usually deployed using a U-shaped mooring (i.e. buoy or pellet float to wire rope to tide gauge to ground line to anchor to wire rope to buoy), but W-shaped moorings are used in conjunction with either current meters or thermistor chains. A W-shaped mooring comprises pellet float to pellet line to sub-surface buoy to current meter or thermistor line to anchor weight to ground line to tide gauge to ground line to anchor weight to wire rope to surface buoy.
Data Processing Notes
Clock gained 3 seconds over 24 days 20 hours 59 minutes 57 seconds; the cycle interval and time values have been corrected.
Instrument Characteristics
Station C6
Aanderaa | 2A/64 (BODC Series Ref. 40966) |
---|---|
Nominal sampling interval | 900 seconds |
Integration period | 104 seconds |
This instrument was deployed on the same frame as a Mark II tide gauge.
IOS Data Processing of Off-Shore Pressure Recorder Data
Data processing comprises 2 stages:-
-
Instrumental drift and depth are removed, thus the drift free series is produced with an artificial mean of zero.
-
Generally the pressure values have been obtained by integration and averaging over the sampling interval, followed by logging; hence the time value assigned to a data cycle has been chosen as the mid-point between the start and end time of each interval. Some pressure records have been sample rate reduced from the basic time step of the recorder to produce either hourly or 15 minute values, incorporating any timing corrections due to clock error.
Project Information
No Project Information held for the Series
Data Activity or Cruise Information
No Data Activity or Cruise Information held for the Series
Fixed Station Information
No Fixed Station Information held for the Series
BODC Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
Blank | Unqualified |
< | Below detection limit |
> | In excess of quoted value |
A | Taxonomic flag for affinis (aff.) |
B | Beginning of CTD Down/Up Cast |
C | Taxonomic flag for confer (cf.) |
D | Thermometric depth |
E | End of CTD Down/Up Cast |
G | Non-taxonomic biological characteristic uncertainty |
H | Extrapolated value |
I | Taxonomic flag for single species (sp.) |
K | Improbable value - unknown quality control source |
L | Improbable value - originator's quality control |
M | Improbable value - BODC quality control |
N | Null value |
O | Improbable value - user quality control |
P | Trace/calm |
Q | Indeterminate |
R | Replacement value |
S | Estimated value |
T | Interpolated value |
U | Uncalibrated |
W | Control value |
X | Excessive difference |
SeaDataNet Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
0 | no quality control |
1 | good value |
2 | probably good value |
3 | probably bad value |
4 | bad value |
5 | changed value |
6 | value below detection |
7 | value in excess |
8 | interpolated value |
9 | missing value |
A | value phenomenon uncertain |
B | nominal value |
Q | value below limit of quantification |