Metadata Report for BODC Series Reference Number 580716
Metadata Summary
Problem Reports
Data Access Policy
Narrative Documents
Project Information
Data Activity or Cruise Information
Fixed Station Information
BODC Quality Flags
SeaDataNet Quality Flags
Metadata Summary
Data Description |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Data Identifiers |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Time Co-ordinates(UT) |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Spatial Co-ordinates | |||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Parameters |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
Problem Reports
No Problem Report Found in the Database
Data Access Policy
Public domain data
These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.
The recommended acknowledgment is
"This study uses data from the data source/organisation/programme, provided by the British Oceanographic Data Centre and funded by the funding body."
Narrative Documents
Aanderaa Water Level Recorder Model 7
The Water Level Recorder (WLR) model 7 is a self-contained, high precision instrument specifically designed for recording of ocean water levels through precise measurement of hydrostatic pressure. The WLR records pressure, temperature and conductivity (optional) at regular intervals, enabling precise variations in water level to be calculated. The pressure sensor consists of an oscillating quartz crystal which shifts frequency with the force applied to it. Temperature is measured by a Fenwall thermistor.
The data from the WLR7 are stored in a solid-state data storage unit (DSU) which can store up to 65,500 ten bit, PDC-4 coded words in a set of EEPROMS. Click the link for further details on theWLR7.
Specifications
Pressure
Oscillator Frequency | 36-40 kHz |
---|---|
Resolution | 0.001% of range |
Repeatability | ± 0.01% of full scale |
Integration | 40 s |
Ranges available | 0 - 700 kPA (60 m) (standard) 0 - 3500 kPa (340 m) (standard) |
Temperature
The thermistor is a Fenwall GB32JM19
Range | -3 °C to +35 °C |
---|---|
Accuracy | ± 0.1 °C |
Resolution | 0.04 °C |
Response Time | 30 s |
Conductivity (optional)
Sensor Type | Conductivity Cell 3094 |
---|---|
Ranges | 0 - 77 mmho cm-1 (standard) 0 - 42 mmho cm-1 (on request) |
Accuracy | ± 0.25 mmho cm-1 |
Resolution | 0.1% of range |
Further details can be found in the manufacturer's specification sheet.
BODC processing
The data were provided to BODC in ascii format and were transferred to qxf format by BODC produced Matlab transfer 136. The full dataset was made up from two columns in one file.
There were no headings included in the files to point to which channel refered to which variable. The file had two columns, the first being pressure and the second column was for temperature. The variables were then mapped to the appropriate BODC parameter code which can be seen below:
Variable | Units | BODC parameter code | Units | Comments |
---|---|---|---|---|
Temperature | deg C | TEMPPR01 | deg C | - |
Pressure | dbar | PREXPS01 | dbar | - |
Following the transfer the data was screened using the BODC in-house visualisation software, EDSERPLO. Any suspect data points were flagged with the appropriate BODC flag code.
Originator's data processing
The data from the Vemco Miniloggers were merged to form "pseudo" thermistor chain records prior to being supplied to BODC.
FRS applied the standard manufaturers' calibrations to all data, and produced ascii files for submission to BODC.
Project Information
No Project Information held for the Series
Data Activity or Cruise Information
Data Activity
Start Date (yyyy-mm-dd) | 2001-04-09 |
End Date (yyyy-mm-dd) | 2001-07-17 |
Organization Undertaking Activity | Fisheries Research Services Aberdeen Marine Laboratory (now Marine Scotland Aberdeen Marine Laboratory) |
Country of Organization | United Kingdom |
Originator's Data Activity Identifier | 661w |
Platform Category | fixed benthic node |
FRS moored Aanderaa Water Level Recorder (WLR) from off Loch Torridon (Rona)
A moored Aanderaa water level recorder (WLR) was deployed by Fisheries Research Services (FRS) off Loch Torridon (Rona) (57.57717° N, 5.96933° W) on 09/04/01 as part of the Clupea 0501c cruise, and recovered on 17/07/01 by the Clupea 0901c cruise. The station had a nominal water depth of 27 m. The WLR had a sampling period of 15 minutes. The data were supplied as current meter records at a depth of 27 m.
The mooring consisted of the following instruments.
Instrument type | Series Nunber | Serial Number | Deployment start | Deployment end | Instrument depth (m) | Comments |
---|---|---|---|---|---|---|
Aanderaa WLR 7 | 661w | 940 | 09/04/2001 | 17/07/2001 | 27 | - |
Cruise
Cruise Name | 0501C |
Departure Date | 2001-04-02 |
Arrival Date | 2001-04-11 |
Principal Scientist(s) | Phil A Gillibrand (Fisheries Research Services Aberdeen Marine Laboratory) |
Ship | FRV Clupea |
Complete Cruise Metadata Report is available here
Fixed Station Information
No Fixed Station Information held for the Series
BODC Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
Blank | Unqualified |
< | Below detection limit |
> | In excess of quoted value |
A | Taxonomic flag for affinis (aff.) |
B | Beginning of CTD Down/Up Cast |
C | Taxonomic flag for confer (cf.) |
D | Thermometric depth |
E | End of CTD Down/Up Cast |
G | Non-taxonomic biological characteristic uncertainty |
H | Extrapolated value |
I | Taxonomic flag for single species (sp.) |
K | Improbable value - unknown quality control source |
L | Improbable value - originator's quality control |
M | Improbable value - BODC quality control |
N | Null value |
O | Improbable value - user quality control |
P | Trace/calm |
Q | Indeterminate |
R | Replacement value |
S | Estimated value |
T | Interpolated value |
U | Uncalibrated |
W | Control value |
X | Excessive difference |
SeaDataNet Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
0 | no quality control |
1 | good value |
2 | probably good value |
3 | probably bad value |
4 | bad value |
5 | changed value |
6 | value below detection |
7 | value in excess |
8 | interpolated value |
9 | missing value |
A | value phenomenon uncertain |
B | nominal value |
Q | value below limit of quantification |