Search the data

Metadata Report for BODC Series Reference Number 648686


Metadata Summary

Data Description

Data Category Currents -subsurface Eulerian
Instrument Type
NameCategories
Aanderaa RCM 7/8 Recording Current Meter  current meters
Instrument Mounting subsurface mooring
Originating Country United Kingdom
Originator Ms Sarah Hughes
Originating Organization Fisheries Research Services Aberdeen Marine Laboratory (now Marine Scotland Aberdeen Marine Laboratory)
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) -
 

Data Identifiers

Originator's Identifier 701/4
BODC Series Reference 648686
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 2004-05-20 13:00
End Time (yyyy-mm-dd hh:mm) 2005-02-24 15:00
Nominal Cycle Interval 3600.0 seconds
 

Spatial Co-ordinates

Latitude 60.27070 N ( 60° 16.2' N )
Longitude 9.01330 W ( 9° 0.8' W )
Positional Uncertainty 0.05 to 0.1 n.miles
Minimum Sensor or Sampling Depth 959.0 m
Maximum Sensor or Sampling Depth 959.0 m
Minimum Sensor or Sampling Height 27.0 m
Maximum Sensor or Sampling Height 27.0 m
Sea Floor Depth 986.0 m
Sea Floor Depth Source -
Sensor or Sampling Distribution Fixed common depth - All sensors are grouped effectively at the same depth which is effectively fixed for the duration of the series
Sensor or Sampling Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
Sea Floor Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
 

Parameters

BODC CODERankUnitsTitle
AADYAA011DaysDate (time from 00:00 01/01/1760 to 00:00 UT on day)
AAFDZZ011DaysTime (time between 00:00 UT and timestamp)
LCDAEL011Degrees TrueDirection (towards) of water current (Eulerian measurement) in the water body by in-situ current meter and correction to true North
LCSAEL011Centimetres per secondSpeed of water current (Eulerian measurement) in the water body by in-situ current meter
TEMPPR011Degrees CelsiusTemperature of the water body

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database

Data quality report

Suspect values were identified during screening where current speed and direction both dropped to zero for two or more consecutive data cycles. This is likely to be the result of temporary fouling of the current meter rotor. These suspect data points have been flagged M. Where a small number of non-zero points occur within a long series of zeroes the non-zero data have also been flagged M as it is unlikely that rotor movement was entirely free for a short number of data cycles before the instrument became jammed again.


Data Access Policy

Public domain data

These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.

The recommended acknowledgment is

"This study uses data from the data source/organisation/programme, provided by the British Oceanographic Data Centre and funded by the funding body."


Narrative Documents

Aanderaa Recording Current Meter Model 7/8

Manufacturer's specifications: recording unit height 49.5cm (RCM8 52.0cm), diameter 12.8cm, vane size 48.5x50.0cm. Meter is designed for depths down to 2000m (RCM8 6000m). It incorporates a spindle which is shackled to the mooring line. The meter is attached to the spindle through a gimbal mounting which permits a maximum 27° deviation of the spindle from the vertical, the meter still remaining horizontal.

Meter comprises :

  1. Paddle wheel rotor magnetically coupled to an electronic counter

  2. Vane, which aligns instrument with current flow, has a balance weight ensuring static balance and tail fins to ensure dynamic balance in flows up to 250cm/s.

  3. Magnetic compass (needle is clamped to potentiometer ring) - direction recorded with 0.35° resolution, 5° accuracy for speeds 5 to 100cm/s, 7.5° accuracy for remaining speeds within 2.5 to 200cm/s range.

  4. Quartz clock, accuracy better than 2 sec/day within temperature range 0 to 20°C.

  5. Thermistor (temperature sensor), standard range -2.46 to 21.48°C (max on high range 36.04°C), accuracy 0.05°C, resolution 0.1 per cent of range, 63 per cent response time 12sec.

  6. Inductive cell conductivity sensor (optional), range 0 to 70mmho/cm standard resolution 0.1 per cent of range.

  7. Silicon piezoresistive bridge, standard range 0 to 3000 psi (RCM8 to 9000 psi), resolution 0.1% of range.

  8. Self balancing potentiometer which converts the output from each sensor into a 10 bit binary number for storage on magnetic tape.

  9. Associated electronics.

A built-in clock triggers the instrument at preset intervals and up to six channels are sampled in sequence. Channel 1 is a fixed reference reading for control purposes and data identification. Channels 2, 3 and 4 represent measurement of temperature, conductivity and pressure. Channels 5 and 6 represent the VECTOR AVERAGED current speed and direction since the previous triggering of the instrument. The number of rotor revolutions and the direction is sampled every 12 seconds and broken into North and East components. Successive components are added and recorded as speed and direction. For recording intervals longer than 10 minutes, speed and direction are sampled 1/50th of recording interval.

It has become common practice in some laboratories to deploy these meters as temperature and conductivity loggers without current measuring capabilities.

The following link will provide the manufacturer specifications:

Manufacturer specifications

BODC Processing

Data were received by BODC in ASCII format files. This series was reformatted to the internal QXF format using BODC transfer function 325. The following table shows how the variables within the file were mapped to the appropriate BODC parameter codes.

Original parameter name Original Units Description BODC Parameter Code BODC Units Comments
Time DD/MM/YYYY HH:MI date and time AADYAA01 and AAFDZZ01 day number and day fraction GMT Conversion by transfer
u + v cm/s Eastward and northward current velocity LCDAEL01 (direction) and LCSAEL01 (speed) °, cm/s Converted by transfer to current direction (Eulerian) in the water column by in-situ current meter and correction to true North, and current speed (Eulerian) in the water column by in-situ current meter
T degrees Celsius Temperature TEMPPR01 degrees Celsius  

Following transfer to QXF, the data were screened using BODC's in-house visualisation software, EDSERPLO. Any data considered as suspect were flagged 'M'. Flags from the originator marking suspect data were retained during transfer and flagged 'L'.

Originator's Data Processing

Sampling Strategy

The Aanderaa RCM 7 current meter deployed on the Wyville-Thompson Ridge had a sampling frequency of 1 reading per hour. The instrument included a temperature sensor.

Data Processing

DAF applied the standard manufacturers' calibrations to all current, temperature and salinity data, and produced ASCII files for submission to BODC. Data files were named according to the mooring code (701) and the instrument number (4). The current meter file (7014) contained eastward and northward velocities, and temperature.


Project Information


No Project Information held for the Series

Data Activity or Cruise Information

Data Activity

Start Date (yyyy-mm-dd) 2004-05-20
End Date (yyyy-mm-dd) 2005-02-24
Organization Undertaking ActivityFisheries Research Services Aberdeen Marine Laboratory (now Marine Scotland Aberdeen Marine Laboratory)
Country of OrganizationUnited Kingdom
Originator's Data Activity Identifier701
Platform Categorysubsurface mooring

DAF current meter mooring, Wyville-Thompson Ridge

The mooring was located at 60° 16.24' N, 009° 0.80' W in a nominal water depth of 986 m.

The mooring was deployed on 20 May 2004 by the Department of Agriculture and Fisheries (DAF, now known as Marine Scotland Aberdeen Marine Laboratory) on cruise FRV Scotia 0804S (Part 1) (12 May 2004-30 May 2004), recovered on 24 February 2005, and consisted of the following instruments.

Instrument type Serial Number Deployment start Deployment end Instrument depth (m) Comments
Aanderaa RCM 7 10411 2004-05-20 2005-02-24 959  

Cruise

Cruise Name 0804S_1
Departure Date 2004-05-12
Arrival Date 2004-05-30
Principal Scientist(s)Bill Turrell (Fisheries Research Services Aberdeen Marine Laboratory)
Ship FRV Scotia

Complete Cruise Metadata Report is available here


Fixed Station Information


No Fixed Station Information held for the Series


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification