Metadata Report for BODC Series Reference Number 725916
Metadata Summary
Problem Reports
Data Access Policy
Narrative Documents
Project Information
Data Activity or Cruise Information
Fixed Station Information
BODC Quality Flags
SeaDataNet Quality Flags
Metadata Summary
Data Description |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Data Identifiers |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Time Co-ordinates(UT) |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Spatial Co-ordinates | |||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Parameters |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
Problem Reports
No Problem Report Found in the Database
Data Access Policy
Public domain data
These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.
The recommended acknowledgment is
"This study uses data from the data source/organisation/programme, provided by the British Oceanographic Data Centre and funded by the funding body."
Narrative Documents
Instrument Description
CTD Unit and Auxiliary Sensors
A SAIV SD-204 CTD unit was used. The CTD unit included the following sensors.
Sensor | Manufacturer | Model | Serial number | Calibration date |
---|---|---|---|---|
Pressure | Budenburg | DWT280L | not available | 2000-04-15 |
Temperature | Falmouth | OTM | not available | 2000-04-15 |
Conductivity | Falmouth | OCM | not available | 2000-04-15 |
SAIV SD204 CTD Probe
The SAIV SD204 CTD Probe measures, calculates and records sea water conductivity in mS cm-1, salinity in Kg m-3, temperature in Deg Celsius, depth (pressure) in metre, sound velocity in m s-1.
The sampling interval is 5 seconds.
Further details can be found in the manufacturer's specification sheet.
BODC Processing
Data were received by BODC in one ASCII format file that was subsequently split into seven separate files, one for each CTD profile. The series were reformatted to the internal QXF format using BODC transfer function 340. The following table details the mapping of variables to BODC parameter codes.
Original parameter name | Original Units | Description | BODC Parameter Code | BODC Units | Comments |
---|---|---|---|---|---|
Pressure | Decibars | Pressure exerted by the water column | PRESPR01 | Decibars | |
Temperature | °C | Temperature of the water column | TEMPST01 | °C | |
Conductivity | mS cm-1 | Electrical conductivity of the water column | CNDCST01 | S m-1 | Conversion by transfer (mS cm-1 x 0.1) |
Salinity | Dimensionless | Practical salinity of the water column by CTD and computation using UNESCO 1983 algorithm | PSALST01 | Dimensionless |
Following transfer to QXF, the data were screened using BODC's in-house visualisation software, EDSERPLO. Any data considered as suspect were flagged 'M'. Flags from the originator marking suspect data were retained during transfer and flagged 'L'.
Originator's Data Processing
The raw CTD data files were processed through the SeaBird Electronics SeaSoft data processing software following standard procedures. The originators used in-house interactive visual display editing software to edit out individual spikes in the primary temperature and conductivity channels. An ASCII file was generated for each CTD cast and all files from a cruise were concatenated into one ASCII file which was submitted to BODC.
Project Information
No Project Information held for the Series
Data Activity or Cruise Information
Cruise
Cruise Name | 1206H |
Departure Date | 2006-07-10 |
Arrival Date | 2006-07-14 |
Principal Scientist(s) | John Beaton (Fisheries Research Services Aberdeen Marine Laboratory) |
Ship | Fram |
Complete Cruise Metadata Report is available here
Fixed Station Information
No Fixed Station Information held for the Series
BODC Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
Blank | Unqualified |
< | Below detection limit |
> | In excess of quoted value |
A | Taxonomic flag for affinis (aff.) |
B | Beginning of CTD Down/Up Cast |
C | Taxonomic flag for confer (cf.) |
D | Thermometric depth |
E | End of CTD Down/Up Cast |
G | Non-taxonomic biological characteristic uncertainty |
H | Extrapolated value |
I | Taxonomic flag for single species (sp.) |
K | Improbable value - unknown quality control source |
L | Improbable value - originator's quality control |
M | Improbable value - BODC quality control |
N | Null value |
O | Improbable value - user quality control |
P | Trace/calm |
Q | Indeterminate |
R | Replacement value |
S | Estimated value |
T | Interpolated value |
U | Uncalibrated |
W | Control value |
X | Excessive difference |
SeaDataNet Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
0 | no quality control |
1 | good value |
2 | probably good value |
3 | probably bad value |
4 | bad value |
5 | changed value |
6 | value below detection |
7 | value in excess |
8 | interpolated value |
9 | missing value |
A | value phenomenon uncertain |
B | nominal value |
Q | value below limit of quantification |