Metadata Report for BODC Series Reference Number 750981
Metadata Summary
Problem Reports
Data Access Policy
Narrative Documents
Project Information
Data Activity or Cruise Information
Fixed Station Information
BODC Quality Flags
SeaDataNet Quality Flags
Metadata Summary
Data Description |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Data Identifiers |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Time Co-ordinates(UT) |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Spatial Co-ordinates | |||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Parameters |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
Problem Reports
No Problem Report Found in the Database
Data Access Policy
Open Data supplied by Natural Environment Research Council (NERC)
You must always use the following attribution statement to acknowledge the source of the information: "Contains data supplied by Natural Environment Research Council."
Narrative Documents
Instrument description
Lockheed Martin Sippican T-5 XBT Probe
The Expendable Bathythermograph system uses a sea water ground. As soon as an electrode within the nose of the expendable probe makes contact with the water, the circuit is complete and temperature or sound velocity data can be telemetered to the ship-board data processing equipment. The T-5 XBT Probe can be used within a maximum depth of 1830 m, with a rated ship speed of 6 knots and has a vertical resolution of 65 cm.
Manufacturer specifications can be found here
BODC Processing
The data arrived at BODC in 27 ASCII format files representing the casts taken during JR20071029. These were reformatted to the internal QXF format using BODC transfer funciton 388. The following table shows how the variables within the ASCII files were mapped to appropriate BODC parameter codes:
Originator's Variable | Units | Description | BODC Parameter Code | Units | Comments |
---|---|---|---|---|---|
Depth | m | Depth of instrument | DEPHCV01 | m | |
Sound Velocity | ms-1 | Velocity of sound through water column | SVELVP01 | ms-1 | |
Temperature | °C | Temperature of water | TEMPET01 | °C |
The reformatted data were visualised using the in-house EDSERPLO software. Suspect data were marked by adding an appropriate quality control flag, missing data by both setting the data to an appropriate value and setting the quality control flag.
General Data Screening carried out by BODC
BODC screen both the series header qualifying information and the parameter values in the data cycles themselves.
Header information is inspected for:
- Irregularities such as unfeasible values
- Inconsistencies between related information, for example:
- Times for instrument deployment and for start/end of data series
- Length of record and the number of data cycles/cycle interval
- Parameters expected and the parameters actually present in the data cycles
- Originator's comments on meter/mooring performance and data quality
Documents are written by BODC highlighting irregularities which cannot be resolved.
Data cycles are inspected using time or depth series plots of all parameters. Currents are additionally inspected using vector scatter plots and time series plots of North and East velocity components. These presentations undergo intrinsic and extrinsic screening to detect infeasible values within the data cycles themselves and inconsistencies as seen when comparing characteristics of adjacent data sets displaced with respect to depth, position or time. Values suspected of being of non-oceanographic origin may be tagged with the BODC flag denoting suspect value; the data values will not be altered.
The following types of irregularity, each relying on visual detection in the plot, are amongst those which may be flagged as suspect:
- Spurious data at the start or end of the record.
- Obvious spikes occurring in periods free from meteorological disturbance.
- A sequence of constant values in consecutive data cycles.
If a large percentage of the data is affected by irregularities then a Problem Report will be written rather than flagging the individual suspect values. Problem Reports are also used to highlight irregularities seen in the graphical data presentations.
Inconsistencies between the characteristics of the data set and those of its neighbours are sought and, where necessary, documented. This covers inconsistencies such as the following:
- Maximum and minimum values of parameters (spikes excluded).
- The occurrence of meteorological events.
This intrinsic and extrinsic screening of the parameter values seeks to confirm the qualifying information and the source laboratory's comments on the series. In screening and collating information, every care is taken to ensure that errors of BODC making are not introduced.
Instrument Description
XBT Unit and Auxiliary Sensors
Probe Type | T-5 |
Terminal Depth | 1830 m |
Depth Equation | Standard |
Depth Coeff. 1 | 0.0 |
Depth Coeff. 2 | 6.828 |
Depth Coeff. 3 | -0.00182 |
Depth Coeff. 4 | 0.0 |
Pressure Pt Correction | 100.0% |
Project Information
BAS Long Term Monitoring and Survey
Introduction
The Long Term Monitoring and Survey project (LTMS) has been running since the British Antarctic Survey (BAS) was created. This project is one of the BAS core projects, with several groups of scientists collecting various types of data e.g biological, geological, atmospheric, among others.
Data collection is achievable through a wide scope of instruments and platforms, e.g. the Antarctic research stations, autonomous instrument platforms deployed on or from BAS research ships, BAS aircrafts, satellite remote sensing and others.
Scientific Objectives
This project was implemented in order to measure change and variability in the Earth system. Its long term duration allows for the monitoring of processes that could be missed in shorter term studies and experiments. The data collected is also used to check and improve the reliability of models used to stimulate and predict the behavior of the Earth system.
The main objectives are:
- Topographic survey
- Geosciences survey
- Biological survey and monitoring
- Atmospheric and oceanographic monitoring
Data Availability
The data sets obtained through this project are available to the academic community.
Data Activity or Cruise Information
Cruise
Cruise Name | JR20071029 (JR184) |
Departure Date | 2007-10-29 |
Arrival Date | 2007-11-21 |
Principal Scientist(s) | Peter Enderlein (British Antarctic Survey) |
Ship | RRS James Clark Ross |
Complete Cruise Metadata Report is available here
Fixed Station Information
No Fixed Station Information held for the Series
BODC Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
Blank | Unqualified |
< | Below detection limit |
> | In excess of quoted value |
A | Taxonomic flag for affinis (aff.) |
B | Beginning of CTD Down/Up Cast |
C | Taxonomic flag for confer (cf.) |
D | Thermometric depth |
E | End of CTD Down/Up Cast |
G | Non-taxonomic biological characteristic uncertainty |
H | Extrapolated value |
I | Taxonomic flag for single species (sp.) |
K | Improbable value - unknown quality control source |
L | Improbable value - originator's quality control |
M | Improbable value - BODC quality control |
N | Null value |
O | Improbable value - user quality control |
P | Trace/calm |
Q | Indeterminate |
R | Replacement value |
S | Estimated value |
T | Interpolated value |
U | Uncalibrated |
W | Control value |
X | Excessive difference |
SeaDataNet Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
0 | no quality control |
1 | good value |
2 | probably good value |
3 | probably bad value |
4 | bad value |
5 | changed value |
6 | value below detection |
7 | value in excess |
8 | interpolated value |
9 | missing value |
A | value phenomenon uncertain |
B | nominal value |
Q | value below limit of quantification |