Search the data

Metadata Report for BODC Series Reference Number 1039489


Metadata Summary

Data Description

Data Category Offshore sea floor pressure series
Instrument Type
NameCategories
Vemco Minilog8 temperature recorder  water temperature sensor
Instrument Mounting fixed benthic node
Originating Country United Kingdom
Originator Ms Sarah Hughes
Originating Organization Marine Scotland Aberdeen Marine Laboratory
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) -
 

Data Identifiers

Originator's Identifier 776/W
BODC Series Reference 1039489
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 2009-07-21 20:00
End Time (yyyy-mm-dd hh:mm) 2009-08-04 10:30
Nominal Cycle Interval 180.0 seconds
 

Spatial Co-ordinates

Latitude 58.65133 N ( 58° 39.1' N )
Longitude 3.30117 W ( 3° 18.1' W )
Positional Uncertainty 0.05 to 0.1 n.miles
Minimum Sensor or Sampling Depth 29.0 m
Maximum Sensor or Sampling Depth 29.0 m
Minimum Sensor or Sampling Height 0.0 m
Maximum Sensor or Sampling Height 0.0 m
Sea Floor Depth 29.0 m
Sea Floor Depth Source -
Sensor or Sampling Distribution Fixed common depth - All sensors are grouped effectively at the same depth which is effectively fixed for the duration of the series
Sensor or Sampling Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
Sea Floor Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
 

Parameters

BODC CODERankUnitsTitle
AADYAA011DaysDate (time from 00:00 01/01/1760 to 00:00 UT on day)
AAFDZZ011DaysTime (time between 00:00 UT and timestamp)
PREXPS011DecibarsPressure (measured variable) exerted by the water body by fixed in-situ pressure sensor and corrected to read zero at sea level
TEMPPR011Degrees CelsiusTemperature of the water body

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database


Data Access Policy

Public domain data

These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.

The recommended acknowledgment is

"This study uses data from the data source/organisation/programme, provided by the British Oceanographic Data Centre and funded by the funding body."


Narrative Documents

Vemco Minilog8 TR temperature logger

The VEMCO Minilog8-TR is a miniature data logger that records temperature at a user programmed time interval. It is housed in a waterproof cylinder and the temperature sensor is mounted on a protruding stainless steel probe.

Specifications

Memory 16 or 64k memory size, approximately 8000 readings stored in non-volatile Electrically Erasable Programmable Read Only Memory (EEPROM). Logging duration is between 1 second to 6 hours for up to 5 years depending on the logging interval.
Data Retention 20 years.
Temperature Range -5 to 40 °C; 0.1-0.2 °C resolution; ±0.2-0.3 °C accuracy with factory calibration.
Maximum Depth 680 m
Communication Link Infrared LED. No external connections are required. Full memory downloads in 3 to 6 minutes.
Battery Internal lithium battery with life of up to 5 years or up to 700- 1000 full deployments.

Further details can be found in the manufacturer's specification sheet.

BODC Processing

Data were received in ASCII format files. Pressure offsets were applied to the data where indicated as necessary by the originator. The series were transferred to BODC's in-house format. The following table shows how the variables within the file were mapped to the appropriate BODC parameter codes.

Original parameter name Original Units BODC Parameter Code BODC Units Comments
Pressure decibars PREXPS01 decibars  
Depth m DEPHFP01 m Not derived for all moorings
Temperature °C TEMPPR01 °C Not measured at all moorings

Following reformatting, the data were visually screened. Any data considered suspect were flagged accordingly. Flags from the originator's quality control were retained during transfer.

Originator's Data Processing

Marine Scotland applied the standard manufacturers' calibrations to all water level recorder (WLR)/Minilogger data and produced ASCII files for submission to BODC. Data files (.hmo) were named according to the mooring code and the instrument number. Files contained water level data in meters (WLR) or decibars (Minilogger). Minilogger files also contained temperature data. Header metadata were collated in additional files (.frm).


Project Information


No Project Information held for the Series

Data Activity or Cruise Information

Data Activity

Start Date (yyyy-mm-dd) 2009-07-21
End Date (yyyy-mm-dd) 2009-08-04
Organization Undertaking ActivityMarine Scotland Aberdeen Marine Laboratory
Country of OrganizationUnited Kingdom
Originator's Data Activity Identifier776w
Platform Categoryfixed benthic node

FRS Minilogger (776w) from Pentland Firth

A bottom mounted, pressure recording VEMCO Minilogger was deployed by Marine Scotland, Aberdeen Marine Laboratory in the Pentland Firth (58° 39.08'N 03° 18.07'W). The instrument was deployed on 21/07/2009 and recovered on 04/08/2009, during the FRV Scotia cruise 1009S. The station had a nominal water depth of 29m.

The mooring consisted of the following instruments

Instrument type Series Number Serial Number Deployment start Deployment end Instrument depth (m) No. Readings/Hour Comments
VEMCO Minilogger 776w 2827 21/07/2009 04/08/2009 29 20 -

Cruise

Cruise Name 1009S
Departure Date 2009-07-19
Arrival Date 2009-08-05
Principal Scientist(s)Peter Hayes (Marine Scotland Aberdeen Marine Laboratory)
Ship FRV Scotia

Complete Cruise Metadata Report is available here


Fixed Station Information


No Fixed Station Information held for the Series


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification