Metadata Report for BODC Series Reference Number 1074518
Metadata Summary
Problem Reports
Data Access Policy
Narrative Documents
Project Information
Data Activity or Cruise Information
Fixed Station Information
BODC Quality Flags
SeaDataNet Quality Flags
Metadata Summary
Data Description |
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
Data Identifiers |
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
Time Co-ordinates(UT) |
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
Spatial Co-ordinates | |||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
Parameters |
|||||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||||
|
Problem Reports
No Problem Report Found in the Database
Data Access Policy
Open Data
These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.
If the Information Provider does not provide a specific attribution statement, or if you are using Information from several Information Providers and multiple attributions are not practical in your product or application, you may consider using the following:
"Contains public sector information licensed under the Open Government Licence v1.0."
Narrative Documents
James Clark Ross Cruise AMT9 CTD Instrumentation
Instrumentation
Sea-Bird Electronics 911plus CTD (with SBE9 CTD and SBE11 deck unit)
Rosette fitted with 12 30-litre Niskin water bottles
Wet Labs Cstar transmissometer model 9706011, SN CST-153R
Sea-Bird Electronics SBE 911 and SBE 917 series CTD profilers
The SBE 911 and SBE 917 series of conductivity-temperature-depth (CTD) units are used to collect hydrographic profiles, including temperature, conductivity and pressure as standard. Each profiler consists of an underwater unit and deck unit or SEARAM. Auxiliary sensors, such as fluorometers, dissolved oxygen sensors and transmissometers, and carousel water samplers are commonly added to the underwater unit.
Underwater unit
The CTD underwater unit (SBE 9 or SBE 9 plus) comprises a protective cage (usually with a carousel water sampler), including a main pressure housing containing power supplies, acquisition electronics, telemetry circuitry, and a suite of modular sensors. The original SBE 9 incorporated Sea-Bird's standard modular SBE 3 temperature sensor and SBE 4 conductivity sensor, and a Paroscientific Digiquartz pressure sensor. The conductivity cell was connected to a pump-fed plastic tubing circuit that could include auxiliary sensors. Each SBE 9 unit was custom built to individual specification. The SBE 9 was replaced in 1997 by an off-the-shelf version, termed the SBE 9 plus, that incorporated the SBE 3 plus (or SBE 3P) temperature sensor, SBE 4C conductivity sensor and a Paroscientific Digiquartz pressure sensor. Sensors could be connected to a pump-fed plastic tubing circuit or stand-alone.
Temperature, conductivity and pressure sensors
The conductivity, temperature, and pressure sensors supplied with Sea-Bird CTD systems have outputs in the form of variable frequencies, which are measured using high-speed parallel counters. The resulting count totals are converted to numeric representations of the original frequencies, which bear a direct relationship to temperature, conductivity or pressure. Sampling frequencies for these sensors are typically set at 24 Hz.
The temperature sensing element is a glass-coated thermistor bead, pressure-protected inside a stainless steel tube, while the conductivity sensing element is a cylindrical, flow-through, borosilicate glass cell with three internal platinum electrodes. Thermistor resistance or conductivity cell resistance, respectively, is the controlling element in an optimized Wien Bridge oscillator circuit, which produces a frequency output that can be converted to a temperature or conductivity reading. These sensors are available with depth ratings of 6800 m (aluminium housing) or 10500 m (titanium housing). The Paroscientific Digiquartz pressure sensor comprises a quartz crystal resonator that responds to pressure-induced stress, and temperature is measured for thermal compensation of the calculated pressure.
Additional sensors
Optional sensors for dissolved oxygen, pH, light transmission, fluorescence and others do not require the very high levels of resolution needed in the primary CTD channels, nor do these sensors generally offer variable frequency outputs. Accordingly, signals from the auxiliary sensors are acquired using a conventional voltage-input multiplexed A/D converter (optional). Some Sea-Bird CTDs use a strain gauge pressure sensor (Senso-Metrics) in which case their pressure output data is in the same form as that from the auxiliary sensors as described above.
Deck unit or SEARAM
Each underwater unit is connected to a power supply and data logging system: the SBE 11 (or SBE 11 plus) deck unit allows real-time interfacing between the deck and the underwater unit via a conductive wire, while the submersible SBE 17 (or SBE 17 plus) SEARAM plugs directly into the underwater unit and data are downloaded on recovery of the CTD. The combination of SBE 9 and SBE 17 or SBE 11 are termed SBE 917 or SBE 911, respectively, while the combinations of SBE 9 plus and SBE 17 plus or SBE 11 plus are termed SBE 917 plus or SBE 911 plus.
Specifications
Specifications for the SBE 9 plus underwater unit are listed below:
Parameter | Range | Initial accuracy | Resolution at 24 Hz | Response time |
---|---|---|---|---|
Temperature | -5 to 35°C | 0.001°C | 0.0002°C | 0.065 sec |
Conductivity | 0 to 7 S m-1 | 0.0003 S m-1 | 0.00004 S m-1 | 0.065 sec (pumped) |
Pressure | 0 to full scale (1400, 2000, 4200, 6800 or 10500 m) | 0.015% of full scale | 0.001% of full scale | 0.015 sec |
Further details can be found in the manufacturer's specification sheet.
Paroscientific Absolute Pressure Transducers Series 3000 and 4000
Paroscientific Series 3000 and 4000 pressure transducers use a Digiquartz pressure sensor to provide high accuracy and precision data. The sensor comprises a quartz crystal resonator that responds to pressure-induced stress, and temperature is measured for thermal compensation of the calculated pressure.
The 3000 series of transducers includes one model, the 31K-101, whereas the 4000 series includes several models, listed in the table below. All transducers exhibit repeatability of better than ±0.01% full pressure scale, hysteresis of better than ±0.02% full scale and acceleration sensitivity of ±0.008% full scale /g (three axis average). Pressure resolution is better than 0.0001% and accuracy is typically 0.01% over a broad range of temperatures.
Differences between the models lie in their pressure and operating temperature ranges, as detailed below:
Model | Max. pressure (psia) | Max. pressure (MPa) | Temperature range (°C) |
---|---|---|---|
31K-101 | 1000 | 6.9 | -54 to 107 |
42K-101 | 2000 | 13.8 | 0 to 125 |
43K-101 | 3000 | 20.7 | 0 to 125 |
46K-101 | 6000 | 41.4 | 0 to 125 |
410K-101 | 10000 | 68.9 | 0 to 125 |
415K-101 | 15000 | 103 | 0 to 50 |
420K-101 | 20000 | 138 | 0 to 50 |
430K-101 | 30000 | 207 | 0 to 50 |
440K-101 | 40000 | 276 | 0 to 50 |
Further details can be found in the manufacturer's specification sheet.
WETLabs C-Star transmissometer
This instrument is designed to measure beam transmittance by submersion or with an optional flow tube for pumped applications. It can be used in profiles, moorings or as part of an underway system.
Two models are available, a 25 cm pathlength, which can be built in aluminum or co-polymer, and a 10 cm pathlength with a plastic housing. Both have an analog output, but a digital model is also available.
This instrument has been updated to provide a high resolution RS232 data output, while maintaining the same design and characteristics.
Specifications
Pathlength | 10 or 25 cm |
Wavelength | 370, 470, 530 or 660 nm |
Bandwidth | ~ 20 nm for wavelengths of 470, 530 and 660 nm ~ 10 to 12 nm for a wavelength of 370 nm |
Temperature error | 0.02 % full scale °C-1 |
Temperature range | 0 to 30°C |
Rated depth | 600 m (plastic housing) 6000 m (aluminum housing) |
Further details are available in the manufacturer's specification sheet or user guide.
James Clark Ross Cruise AMT9 CTD Processing
Originator's Processing
The CTD profiles were processed onboard using Sea-Bird's data processing software.
BODC data processing
-
Reformatting
The data files were sent to BODC in Sea-Bird's data processing software output. All available channels were listed into ASCII format. Non-null channels were then converted to PXF, a BODC internal format. The data were processed from 1Hz averaged down- and upcast data. Sigma-theta was calculated and output from the raw data during the conversion to PXF format.
Parameters
Originator's Parameter Originator's Units Description BODC code BODC Units Comments Depth m Pressure PRESPR01 decibars Converted from depth to pressure during transfer to PXF Temperature °C Temperature TEMPCU01 °C - Salinity - Salinity PSALCU01 - - Voltage 0 V Beam attenuation ATTNMS01 m-1 Calibrated to zero in clear water - - Potential temperature POTMCV01 °C Computed using UNESCO POTEMP function - - Sigma-theta SIGTPR01 kg m-3 Computed using UNESCO SVAN function -
Screening
The PXF data were compared with the original data files to ensure that no errors had been introduced during the conversion process. The data channels were then screened on a graphics workstation using in-house visualisation software. This allows multiple channels to be viewed simultaneously. The start and end-points of the downcast were marked. The pressure ranges over which bottles were fired were also marked. The bottle firing events were identified by disturbances in CTD parameters on the upcast profiles. All spurious and null data were flagged with appropriate BODC quality control flags.The secondary temperature and salinity channels were used to aid screening of the primary channels only. The primary channels should be used in preference to the secondary channel as they have been quality controlled.
The tranmissometer data for many of the casts had many spikes and large areas with low values. In particular, A9034 showed low values that appeared to be suspect, and were flagged.
There were only a few spikes in the temperature and salinity channels.
-
Loading into the BODC database
After the data had been screened and quality controlled, the data were loaded into the BODC database under the Oracle RDBMS.
The data from all 38 casts were loaded into the data tables.
Calibrations
-
Pressure
The pressure sensor had a mean reading of -0.6 decibar while the CTD was logging in air - this was identified during BODC processing. A pressure correction was, therefore, applied to the data when they were listed from the BODC database.
PRESPR01(corr) = PRESPR01(raw) + 0.6 decibar (BODC calibration 1724)
A separate pressure correction was required for cast AMT9023:
PRESPR01(corr) = PRESPR01(raw) + 4.35 decibar (BODC calibration 3426)
-
Temperature
No reversing thermometer data were available for AMT9, so the CTD sensor data have not been calibrated against another data set. However, the Sea-Bird sensors were tested and calibrated before and after the cruise, and manufacturer's calibrations were applied during Sea-Bird processing. No further correction has been applied to the data at BODC.
-
Salinity
No bench salinometer data are available for AMT9, so no further calibration of the salinity channel is possible. Users should be aware that the data are uncalibrated and may not be accurate.
-
Beam attenuation coefficient
The Sea-Bird data files contained a transmissometer voltage channel. These data were converted to beam attenuation using the manufacturer's calibration information.
Beam attenuation = -1 / x * ln ((Vsig - Vd) / (Vref - Vd)),
where x is the pathlength (0.25m), Vsig is the output voltage, Vd is the blocked path reading (0.059), Vref is the output in clean water (4.678).
No transmissometer air readings were available from the cruise, so the data have not been corrected for possible source decay during the course of the cruise.
Project Information
The Atlantic Meridional Transect (AMT) - Phase 1 (1995-2000)
Who was involved in the project?
The Atlantic Meridional Transect (AMT) programme was designed by and implemented as a collaboration between Plymouth Marine Laboratory (PML) and Southampton Oceanography Centre (SOC). The programme was hosted by Plymouth Marine Laboratory and involved additional researchers from UK and international universities throughout its duration.
What was the project about?
When AMT began in 1995 the programme provided a platform for international scientific collaboration, including the calibration and validation of SeaWiFs measurements and products. The programme provided an exceptional opportunity for nationally and internationally driven collaborative research and provided a platform for excellent multi-disciplinary oceanographic research. As an in situ observation system, the data collected by the AMT consortium informed on changes in biodiversity and function of the Atlantic ecosystem during this period of rapid change to our climate and biosphere.
The scientific aims were to assess:
- mesoscale to basin scale phytoplankton processes
- the functional interpretation of bio-optical signatures
- the seasonal, regional and latitudinal variations in mesozooplankton dynamics
When was the project active?
The first phase of the AMT programme ran from 1995 to 2000 and consisted of a total of 12 cruises. A second phase of funding allowed the project to continue for the period 2002 to 2006 with a further 6 cruises.
Brief summary of the project fieldwork/data
The AMT programme undertook biological, chemical and physical oceanographic research during the annual return passage of the RRS James Clark Ross between the UK and the Falkland Islands or the RRS Discovery between the UK and Cape Town, a distance of up to 13,500 km. This transect crossed a range of ecosystems from sub-polar to tropical and from euphotic shelf seas and upwelling systems to oligotrophic mid-ocean gyres. The transect route was covered north-south in September/October and south-north in April/May of each year.
The measurements of hydrographic and bio-optical properties, plankton community structure and primary production completed on the first 12 transects (1995-2000) represent the most coherent set of repeated biogeochemical observations over ocean basin scales. This unique dataset has led to several important discoveries concerning the identification of oceanic provinces, validation of ocean colour algorithms, distributions of picoplankton, identifying new regional sinks of pCO2 and variability in rates of primary production and respiration.
Who funded the project?
The programme was funded by the Natural Environment Research Council (NERC) and further support was received from the National Aeronautics and Space Administration (NASA) with equipment and funding from the Sea-viewing Wild Field-of-view Sensor (SeaWiFS) project.
Data Activity or Cruise Information
Cruise
Cruise Name | JR19990915 (AMT9, JR45) |
Departure Date | 1999-09-15 |
Arrival Date | 1999-10-13 |
Principal Scientist(s) | Nigel Rees (Plymouth Marine Laboratory) |
Ship | RRS James Clark Ross |
Complete Cruise Metadata Report is available here
Fixed Station Information
No Fixed Station Information held for the Series
BODC Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
Blank | Unqualified |
< | Below detection limit |
> | In excess of quoted value |
A | Taxonomic flag for affinis (aff.) |
B | Beginning of CTD Down/Up Cast |
C | Taxonomic flag for confer (cf.) |
D | Thermometric depth |
E | End of CTD Down/Up Cast |
G | Non-taxonomic biological characteristic uncertainty |
H | Extrapolated value |
I | Taxonomic flag for single species (sp.) |
K | Improbable value - unknown quality control source |
L | Improbable value - originator's quality control |
M | Improbable value - BODC quality control |
N | Null value |
O | Improbable value - user quality control |
P | Trace/calm |
Q | Indeterminate |
R | Replacement value |
S | Estimated value |
T | Interpolated value |
U | Uncalibrated |
W | Control value |
X | Excessive difference |
SeaDataNet Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
0 | no quality control |
1 | good value |
2 | probably good value |
3 | probably bad value |
4 | bad value |
5 | changed value |
6 | value below detection |
7 | value in excess |
8 | interpolated value |
9 | missing value |
A | value phenomenon uncertain |
B | nominal value |
Q | value below limit of quantification |