Metadata Report for BODC Series Reference Number 1201297


Metadata Summary

Data Description

Data Category Currents -subsurface Lagrangian
Instrument Type
NameCategories
U.S. Sensor Ultra Precision Interchangeable Thermistors  water temperature sensor
Navman Jupiter 32 GPS receiver module  NAVSTAR Global Positioning System receivers
Omega KFH series strain gauge  Performance monitors
Instrument Mounting drifting surface float
Originating Country United Kingdom
Originator Dr Marie Porter
Originating Organization Scottish Association for Marine Science
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) FASTNEt
 

Data Identifiers

Originator's Identifier D376_DRIFTER_07
BODC Series Reference 1201297
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 2012-06-14 21:00
End Time (yyyy-mm-dd hh:mm) 2012-10-08 15:00
Nominal Cycle Interval 10800.0 seconds
 

Spatial Co-ordinates

Start Latitude 47.57440 N ( 47° 34.5' N )
End Latitude 43.58500 N ( 43° 35.1' N )
Start Longitude 7.34480 W ( 7° 20.7' W )
End Longitude 6.53620 W ( 6° 32.2' W )
Positional Uncertainty 0.0 to 0.01 n.miles
Minimum Sensor or Sampling Depth 0.0 m
Maximum Sensor or Sampling Depth 50.0 m
Minimum Sensor or Sampling Height -
Maximum Sensor or Sampling Height -
Sea Floor Depth -
Sea Floor Depth Source -
Sensor or Sampling Distribution Scattered at fixed depths - The sensors are scattered with respect to depth but each remains effectively at the same depth for the duration of the series
Sensor or Sampling Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
Sea Floor Depth Datum -
 

Parameters

BODC CODERankUnitsTitle
AADYAA011DaysDate (time from 00:00 01/01/1760 to 00:00 UT on day)
AAFDZZ011DaysTime (time between 00:00 UT and timestamp)
ACYCAA011DimensionlessSequence number
ALATGP011DegreesLatitude north relative to WGS84 by unspecified GPS system
ALONGP011DegreesLongitude east relative to WGS84 by unspecified GPS system
ENGPSG011DimensionlessRaw signal (counts) of instrument output by strain gauge
TEMPTC011Degrees CelsiusTemperature of the water body by in-situ thermistor

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database

D376 MetOcean SVP-Iridium Drifter Data Quality Report

End of normal operation

The data originator in collaboration with BODC has identified the following likely point in time at which each drifter is no longer considered to be operating in its intended state, the reason which has been inferred for this end and the explanation for this determination:

Drifter number Date of last data cycle in data banked by BODC End of normal operation Reason for end of normal operation Explanation for end of normal operation
1 03/12/2012 22/11/2012 Drogue loss Sustained reduction in strain count
2 30/10/2012 05/07/2012 Drogue loss Sustained reduction in strain count
3 30/10/2012 25/09/2012 Drogue loss Sustained reduction in strain count
4 30/10/2012 20/09/2012 Drogue loss Sustained reduction in strain count
5 30/10/2012 29/06/2012 Drogue loss Sustained reduction in strain count
6 24/01/2013 17/01/2013 Drogue loss Sustained reduction in strain count
7 08/10/2012 13/07/2012 Drogue loss Sustained reduction in strain count
8 30/10/2012 18/10/2012 Grounded Stationary position
9 19/08/2012 26/06/2012 Strain gauge fault Maximum strain count followed by erratic strain count
10 25/01/2012 16/01/2012 Drogue loss Sustained reduction in strain count
11 30/10/2012 20/07/2012 Drogue loss Sustained reduction in strain count
12 30/10/2012 01/08/2012 Drogue loss Sustained reduction in strain count
13 07/01/2013 22/12/2012 Grounded on this date and subsequently brought ashore Increase in strain rate and stationary position accompanied by large temperature variations. This was followed by a decrease to low strain values and a brief movement with the new position being on land.
14 05/11/2012 11/10/2012 Drogue loss Sustained reduction in strain count
15 25/10/2012 27/08/2012 Strain gauge fault Increase in strain count to maximum
18/10/2012 Grounded Stationary position
16 30/11/2012 25/11/2012 Grounded on this date and subsequently brought ashore Increase in strain rate and stationary position. This was followed by a decrease to low strain values and a brief movement with the new position (final data cycle) being on land.
17 03/12/2012 01/11/2012 Drogue loss Sustained reduction in strain count
18 24/11/2012 04/10/2012 Grounded Stationary position
15/10/2012-18/10/2012 Problem obtaining GPS location fix Absence of datacycles in data transferred by BODC due to absent GPS fixes
18/10/2012 Drogue loss Drop in strain count and drifter moving in shallow water. GPS fix problem ends. Low temperature spikes (minimum of -12oC) suggest intermittent exposure of sensor to air.
19 25/01/2013 22/01/2013 Drogue loss Sustained reduction in strain count
20 24/06/2012 24/06/2012 Data transmission failure Absence of data for long period of time after this date

N.B. Whilst the drifter may no longer be operating in its intended state, this does not imply that any of the data points are incorrect. For example the loss of the drogue would mean a drifter is no longer following the movement of water at 50m depth, instead it is following the movement of the surface water/affected by surface winds, but the positional information remains accurate.


Data Access Policy

Open Data supplied by Natural Environment Research Council (NERC)

You must always use the following attribution statement to acknowledge the source of the information: "Contains data supplied by Natural Environment Research Council."


Narrative Documents

Omega KFH series miniature strain gauges

Pre-wired, miniature strain gauges. The series contains linear pattern precision gauges (0.3 mm to 20 mm grids), planar XY pattern (Tee Rosette) (0 / 90°) gauges (0.6 to 6 mm grids) and planar rosette pattern (0 / 45 / 90°) gauges (0.6 to 6 mm grids). All models are available with 1 or 3 meter leads, 120 or 350 nominal resistance (ohms).

Specifications

Parameter
 Sub-parameter
Units Specifications
Strain Gauge Construction   Foil strain gauge with embedded measuring grid
Measuring Grid
 Material   Constantan
 Thickness µm (microinch) 3.8 or 5 (150 or 197) depending upon strain gauge type
Carrier
 Material   Polyimide
 Thickness µm (microinch) 45 ± 10 (1.772 ± 394)
Connections   PTFE wire dia. - 0.051 mm approximately 50 mm2 long connected to AWG 28 ribbon cables (PVC insulated) through solder sleeves in 2- or 3-wire configurations
Nominal Resistance Ω 120 or 350 depending upon gage
Resistance Tolerance % ± 0.35 (± 1, with 0.6 mm and 1.5 mm grid length)
Gauge Factor % Approximately 2 (stated on package)
Gauge Factor Tolerance % ± 1 (± 1.5, with 0.6 mm and 1.5 mm grid length)
 Temperature coefficient of gauge factor 1/K [1/°F] (115 ± 10) x 10-6 [(64 ± 5.5) x 10-6]
 Nominal value of gauge factor temperature coefficient   Specified on each package
Reference Temperature °C (°F) 23
Operating Temperature Range   PTFE cable
 for static measurement (zero point related) °C (°F) -10 to 155 (-14 to 320)
 for dynamic measurement (not zero point related) °C (°F) -10 to 155 (-14 to 320)

Further specifications can be found in the manufacturer's data sheet.

U.S. Sensor Ultra Precision Interchangeable Thermistor

A series of interchangeable, resistive thermistors of electrical component size for use in temperature sensing. Epoxy encapsulated with tinned copper allow wires.

BODC image

Specifications

Thermal time constant: 1 second max. in a well stirred oil bath
10 seconds max. in still air
Dissipation constant: 1 mW/°C
Maximum power rating: 30 mW at 25 °C derated to 1 mW at 125 °C
Interchangeability tolerance: ±0.05 °C from 0-50 °C
Operating temperature: -55 °C to +80 °C
Storage and operation temperatures for best long term stability: -55 ° to +50 °C
Resistance ranges: 2,252 - 50,000 Ohms (at 25 °C)

Navman Jupiter 32 GPS receiver module

A miniature (17.0 x 15.0 mm, 2 g), 20-channel GPS receiver for use in marine buoys. The unit contains a SiRF GSC3 GPS chipset. The Jupiter 32 is the successor to the Jupiter 30. The product was replaced by the Jupiter 32 xLP. Navman Wireless OEM Solutions is now Telit Wireless Solutions.

Sensitivity (assuming a noise value of 3 dB)

Parameter Signal strength C/N0
acquisition - cold start -144 dBm 26 dBHz
acquisition - hot start -155 dBm 15 dBHz
navigation -157 dBm 13 dBHz
tracking -159 dBm 10 dBHz

Horizontal and positional accuracy

Parameter Value
horizontal CEP* 2.2 m
horizontal (2 dRMS) 5.5 m
vertical VEP* 2.0 m
velocity 2D (2 sigma) TBD

* position error 50%

Timing 1 PPS output

1 PPS output < 1 µs, typical ±300 ns ref UTC

Further specifications and information is available in the manufacturer's data sheet.

D376 MetOcean SVP-Iridium Drifter Processing by BODC

The data to be banked by BODC were received as 20 csv files, one for each drifter along with a separate header file. The original real-time data files are archived at BODC and are available upon request.

Parameter Mapping

The received files were reformatted to BODC's internal file format which is a NetCDF subset.

Due to the high variability of the Iridium position Circular Error Probability and numerous associated inaccurate Iridium positions, it was decided that the data should only be sampled at the frequency of the GPS position fixes. All other data cycles were removed at the reformatting stage. Whilst this decreases the temporal resolution of the data, it provides a dataset with reliable positional information upon which useful trajectory and temperature data is reliant.

The following table shows how the variables within the csv files were mapped to appropriate BODC parameter codes:

Originator's Parameter Name Units Description BODC Parameter Code Units Comments
IridMsgSN N/A Iridium Message Series Number - - EP
IridDateTime dd/mm/yyyy hh:mm Iridium Date & Time - - GPS Date & Time used
IridDateTimeUnix Unix format Date & Time Iridium Date & Time in Unix format - - Not required
IridLat Degrees north Iridium Latitude North - - GPSLat used
IridLng Degrees east Iridium Longitude East - - GPSLng used
IridCEP Not known Iridium Circular Error Probability - - EP
EmailTime Not known Not known - - EP
GPSDateTime dd/mm/yyyy hh:mm Navman Jupiter 32 GPS Date & Time AADYAA01 Days -
AAFDZZ01 Time
GPSDateTimeUnix Unix format Date & Time Navman Jupiter 32 GPS Date & Time in Unix format - - Not required
SST(C) oC Sea Surface Temperature TEMPST01 oC -
StrainGague(count) Dimensionless Count of strain exerted by drogue ENGPSG01 Dimensionless Important for determining if the drogue is still attached and if drifter has run aground
Battery(V) V Battery voltage - - EP
SBDTime(sec) Seconds Time taken to transmit Iridium Short Burst Data - - EP
TimeSinceLastFix(min) Minutes Time since the last GPS fix was achieved - - A GPS fix is taken only once every 3 hours. When the value of this parameter does not equal zero, the GPS fix is a repeat of the last fix.
GPSLat Degrees north Navman Jupiter 32 GPS Latitude ALATGP01 Degrees north -
GPSLng Degrees east Navman Jupiter 32 GPS Longitude ALONGP01 Degrees east -
TimeToFirstFix(sec) Seconds Time to first GPS fix - - EP
Signal2NoiseRatio(dB) dB Signal to noise ratio of GPS module - - EP

EP = Engineering parameter which is not required for the use of environmental data.

Screening

The reformatted data were visualised using the in-house EDSERPLO software. No data values were edited or deleted at this stage. The improbable data value flag 'M' has been applied where the data appear not to represent valid environmental conditions including strain gauge faults and some instances where the temperature sensor values suggest it has been exposed to the air. Differences in the interval between time stamps exist due to occasional variability in the interval between GPS fixes. Details of the end of each drifter's normal operation are documented in the data quality report.

Banking

Once quality control screening was complete, the data were archived in the BODC National Oceanographic Database and the associated metadata were loaded into an ORACLE Relational Database Management System.

MetOcean SVP-Iridium Drifter Originator Processing

Sampling Strategy

Twenty Metocean SVP drifters were deployed on the shelf break at around 47°35'N as part of cruise D376. The were released in 3 groups and transmitted data including GPS location and sea surface temperature every 3 hours.

For further information please see the D376 cruise report.

Data Processing

The real time drifter data including both environmental and engineering parameters was transmitted through the Iridium satellite network. No processing was undertaken on the data by the originator and the near real-time data was supplied to BODC.

D376 MetOcean SVP-Iridium Drifter Instrumentation

Twenty MetOcean Surface Velocity Program (SVP)-Iridium drifters were deployed on the European continental shelf break around 47° 35'N to track currents at 50 m depth. The SVP consisted of a spherical surface unit and an underwater holey-sock drogue attached by a long tether.

The surface buoy was made from injection moulded high impact ABS and contained the communications and sensors. It was equipped with a bi-directional Iridium 9601 Short Burst Data transceiver satellite system communications link, which also provided hourly position information. More accurate position information was provided by a Navman Jupiter 32 GPS System module every three hours. The surface buoy was equipped with a US Sensor Ultra Precision Thermistor sea surface temperature sensor and battery voltage sensor.

The SVP drifter was equipped with a strain gauge drogue presence system to indicate whether the drogue was attached, under increased strain such as during high wave activity or when grounded, or had lost the drogue. The manufacturer supplies the drogue with a standard tether made from plastic coated stainless steel cable, which centres the drogue at 15m depth. However the tether for these drifters were modified to place the drogue at a depth of 50 m to attempt to track water below the mixed layer.

Further information can be found in the product datasheet and the product manual

As described in the cruise report , the drifters were deployed in 3 separate groups, with 6 released near the 300m isobath (drifters 1-6), 8 released near the 600m isobaths (drifters 7-14) and 6 released near the 1100m isobaths (drifters 15-20). High winds and big swells meant that these depths could not be accurately recorded using the altimeter onboard the ship.


Project Information

Fluxes Across Sloping Topography of the North East Atlantic (FASTNEt)

Background

The FASTNEt consortium was funded to deliver NERC's Ocean Shelf Edge Exchange Programme. Commencing in October 2011, this four year study aims to couple established observational techniques, such as moorings and CTDs, with the very latest in autonomous sampling initiatives - including use of Autosub Long Range and gliders. With the aid of novel model techniques, these observations will be utilised to construct a new paradigm of Ocean/Shelf exchange.

Shelf edge regions mark the gateway between the world's deep oceans and shallower coastal seas, linking terrestrial, atmospheric and oceanic carbon pools and influencing biogeochemical fluxes. Shelf edge processes can influence near-shore productivity (and fisheries) and ultimately affect global climate.

FASTNEt brings together researchers from multiple UK organisations. Further collaboration has been established with five Project Partners: the UK Met Office, Marine Scotland Science, Agri-Food and Biosciences Institute, Marine Institute Ireland and Scripps Institution of Oceanography.

Scientific Objectives

  • To determine the seasonality of physical gradients and exchange across the shelf edge by deploying new observational technologies (gliders, Autosub Long Range) and established techniques (long term moorings, drifters)
  • To quantify key exchange mechanisms and to collect new data targeted at testing and improving high resolution models of the shelf edge, by carrying out detailed process studies in contrasting regions of the shelf edge of the NE Atlantic margin
  • To develop a new parameterisation of shelf edge exchange processes suitable for regional-scale models, using improved resolution numerical, and new empirical models constrained by the observations
  • To test the new parameterisations in a regional model in the context of making an assessment of inter-annual variability of ocean-shelf exchange.

Fieldwork

Three survey sites on the UK shelf edge have been selected for FASTNEt. These are a) the Celtic Sea shelf edge, b) Malin shelf and c) North Scotland shelf. Fieldwork is centred around two research cruises. The first, to the Celtic Sea, on RRS Discovery in June 2012. The second cruise visits the Malin shelf on RRS James Cook, during summer 2013. In addition to these dedicated cruises, opportunist cruise activity to the North Scotland shelf has been agreed with project partner Marine Scotland Science. Autonomous technologies will complement observations made during the cruises and provide knowledge of seasonal and inter-annual variability in exchange processes.

Instrumentation

Types of instruments/measurements:

  • Gliders
  • Autosub Long Range
  • Drifter buoys
  • Scanfish
  • Microstructure profilers
  • Moored CTD/CT loggers and ADCPs
  • Shipboard measurements: CTD, underway, nutrients (and other discrete sampling), LADCP, ADCP.

Contacts

Collaborator Organisation
Prof. Mark Inall (lead) Scottish Association for Marine Science, U.K
Dr. Jason Holt National Oceanography Centre, U.K
Dr. Peter Miller Plymouth Marine Laboratory, U.K
Dr. Mattias Green Bangor University, U.K
Prof. Jonathan Sharples University of Liverpool, U.K
Dr. Vasyl Vlasenko University of Plymouth, U.K

Data Activity or Cruise Information

Cruise

Cruise Name D376
Departure Date 2012-06-11
Arrival Date 2012-07-02
Principal Scientist(s)Mark E Inall (Scottish Association for Marine Science)
Ship RRS Discovery

Complete Cruise Metadata Report is available here


Fixed Station Information


No Fixed Station Information held for the Series


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification