Search the data

Metadata Report for BODC Series Reference Number 1795346


Metadata Summary

Data Description

Data Category CTD or STD cast
Instrument Type
NameCategories
Sea-Bird SBE 911plus CTD  CTD; water temperature sensor; salinity sensor
Benthos PSA-916T Sonar Altimeter  altimeters
Sea-Bird SBE 3plus (SBE 3P) temperature sensor  water temperature sensor
Sea-Bird SBE 4C conductivity sensor  salinity sensor
Paroscientific Digiquartz depth sensors  water pressure sensors
Instrument Mounting lowered unmanned submersible
Originating Country Japan
Originator Dr Toshi Gamo
Originating Organization University of Tokyo, Atmosphere and Ocean Research Institute
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) GEOTRACES
 

Data Identifiers

Originator's Identifier BD-12
BODC Series Reference 1795346
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 2012-09-08 02:27
End Time (yyyy-mm-dd hh:mm) -
Nominal Cycle Interval 1.0 decibars
 

Spatial Co-ordinates

Latitude 50.43333 N ( 50° 26.0' N )
Longitude 176.58333 W ( 176° 35.0' W )
Positional Uncertainty 0.0 to 0.01 n.miles
Minimum Sensor or Sampling Depth 0.99 m
Maximum Sensor or Sampling Depth 7322.67 m
Minimum Sensor or Sampling Height -94.67 m
Maximum Sensor or Sampling Height 7227.01 m
Sea Floor Depth 7228.0 m
Sea Floor Depth Source DATAHEAD
Sensor or Sampling Distribution Variable common depth - All sensors are grouped effectively at the same depth, but this depth varies significantly during the series
Sensor or Sampling Depth Datum Approximate - Depth is only approximate
Sea Floor Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
 

Parameters

BODC CODERankUnitsTitle
ACYCAA011DimensionlessSequence number
AHSFZZ011MetresHeight (spatial coordinate) relative to bed surface in the water body
CNDCST011Siemens per metreElectrical conductivity of the water body by CTD
POTMCV011Degrees CelsiusPotential temperature of the water body by computation using UNESCO 1983 algorithm
PRESPR011DecibarsPressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level
PSALCU011DimensionlessPractical salinity of the water body by CTD and computation using UNESCO 1983 algorithm and NO calibration against independent measurements
SIGTPR011Kilograms per cubic metreSigma-theta of the water body by CTD and computation from salinity and potential temperature using UNESCO algorithm
TEMPST011Degrees CelsiusTemperature of the water body by CTD or STD

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database


Data Access Policy

Public domain data

These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.

The recommended acknowledgment is

"This study uses data from the data source/organisation/programme, provided by the British Oceanographic Data Centre and funded by the funding body."


Narrative Documents

Benthos Programmable Sonar Altimeter (PSA) 916 and 916T

The PSA 916 is a submersible altimeter that uses the travel time of an acoustic signal to determine the distance of the instrument from a target surface. It provides the user with high resolution altitude or range data while simultaneously outputting data through a digital serial port. A wide beam angle provides for reliable and accurate range measurements under the most severe operational conditions. The instrument is electronically isolated to eliminate any potential signal interference with host instrument sensors. The PSA 916 is an upgrade of the PSA 900.

The standard model (PSA 916) has an operational depth range of 0 - 6000 m, while the titanium PSA 916T has a depth range of 0 - 10000 m. All other specifications for the two versions are the same.

Specifications

Transmit frequency 200 kHz
Transmit pulse width 250 µs
Beam pattern 14° conical
Pulse repetition rate

internal selection: 5 pps

external selection: up to 5 pps- user controlled

Range

100 m full scale

1.0 m guaranteed minimum

0.8 m typical

Range

1 cm for RS232 output

2.5 cm for analog output

Operating depth 6000 m (PSA 916) or 10000 m (PSA 916T)

Further details can be found in the manufacturer's specification sheets for the PSA 916 and the PSA 916T.

Instrument Description

CTD Carousel multi sampling (CTD-CMS)

The CTD-CMS system, attached to the end of a titanium armored cable (8mm o.d.) from the No.2 winch of R.V. Hakuho Maru, consisted of a SBE911plus system with a 24 Niskin-X bottle capacity. This was controlled by a CTD Deck Unit connected to a WINDOWS desktop computer. The CTD unit was switched during stations BD-4 and BD-12 to a unit suitable for depths up to 10000m. During these casts, no additional sensors were used.

All the zinc anodes on the Carousel frames (except for those on the CTD housings) were replaced by aluminum anodes, in order to avoid Zn contamination.

Further details on the CTD-CMS system can be found on page 25 of thecruise report

The system was fitted with the following additional sensors:

Sensor Model Serial number Calibration date Comments
Pressure Digiquartz Paroscientific (6000m) Unknown Precise date unknown, calibrated pre-cruise by Sea-Bird Scientific Inc. Stations 1-3, 5-11, 13-22
Pressure Digiquartz Paroscientific (10000m) Unknown Precise date unknown, calibrated pre-cruise by Sea-Bird Scientific Inc. Stations 4 and 12
Conductivity sensor SBE 4C Unknown Precise date unknown, calibrated pre-cruise by Sea-Bird Scientific Inc. -
Temperature sensor SBE 3plus Unknown Precise date unknown, calibrated pre-cruise by Sea-Bird Scientific Inc. -
Dissolved oxygen SBE 43 Unknown Precise date unknown, calibrated pre-cruise by Sea-Bird Scientific Inc. Not calibrated against independent water samples onboard. Stations 1-3, 5-11, 13-22
Fluorometer Chelsea Aquatracka MK III Unknown Precise date unknown, calibrated pre-cruise by Chelsea Technologies Group Ltd. Not calibrated against independent water samples onboard. Stations 1-3, 5-11, 13-22
CDOM sesor Wetlabs ECO-FL Fluorometer 2435 Unknown Stations 1-3, 5-11, 13-22
Turbidity meter SeaPoint Turbidity Meter Unknown Unknown Stations 1-3, 5-11, 13-22
Pinger Benthos 2216 Deep Sea pinger Unknown Unknown -
Altimeter Benthos PSA-916T Sonar Altimeter Unknown Unknown Station 12 only

Sea-Bird Electronics SBE 911 and SBE 917 series CTD profilers

The SBE 911 and SBE 917 series of conductivity-temperature-depth (CTD) units are used to collect hydrographic profiles, including temperature, conductivity and pressure as standard. Each profiler consists of an underwater unit and deck unit or SEARAM. Auxiliary sensors, such as fluorometers, dissolved oxygen sensors and transmissometers, and carousel water samplers are commonly added to the underwater unit.

Underwater unit

The CTD underwater unit (SBE 9 or SBE 9 plus) comprises a protective cage (usually with a carousel water sampler), including a main pressure housing containing power supplies, acquisition electronics, telemetry circuitry, and a suite of modular sensors. The original SBE 9 incorporated Sea-Bird's standard modular SBE 3 temperature sensor and SBE 4 conductivity sensor, and a Paroscientific Digiquartz pressure sensor. The conductivity cell was connected to a pump-fed plastic tubing circuit that could include auxiliary sensors. Each SBE 9 unit was custom built to individual specification. The SBE 9 was replaced in 1997 by an off-the-shelf version, termed the SBE 9 plus, that incorporated the SBE 3 plus (or SBE 3P) temperature sensor, SBE 4C conductivity sensor and a Paroscientific Digiquartz pressure sensor. Sensors could be connected to a pump-fed plastic tubing circuit or stand-alone.

Temperature, conductivity and pressure sensors

The conductivity, temperature, and pressure sensors supplied with Sea-Bird CTD systems have outputs in the form of variable frequencies, which are measured using high-speed parallel counters. The resulting count totals are converted to numeric representations of the original frequencies, which bear a direct relationship to temperature, conductivity or pressure. Sampling frequencies for these sensors are typically set at 24 Hz.

The temperature sensing element is a glass-coated thermistor bead, pressure-protected inside a stainless steel tube, while the conductivity sensing element is a cylindrical, flow-through, borosilicate glass cell with three internal platinum electrodes. Thermistor resistance or conductivity cell resistance, respectively, is the controlling element in an optimized Wien Bridge oscillator circuit, which produces a frequency output that can be converted to a temperature or conductivity reading. These sensors are available with depth ratings of 6800 m (aluminium housing) or 10500 m (titanium housing). The Paroscientific Digiquartz pressure sensor comprises a quartz crystal resonator that responds to pressure-induced stress, and temperature is measured for thermal compensation of the calculated pressure.

Additional sensors

Optional sensors for dissolved oxygen, pH, light transmission, fluorescence and others do not require the very high levels of resolution needed in the primary CTD channels, nor do these sensors generally offer variable frequency outputs. Accordingly, signals from the auxiliary sensors are acquired using a conventional voltage-input multiplexed A/D converter (optional). Some Sea-Bird CTDs use a strain gauge pressure sensor (Senso-Metrics) in which case their pressure output data is in the same form as that from the auxiliary sensors as described above.

Deck unit or SEARAM

Each underwater unit is connected to a power supply and data logging system: the SBE 11 (or SBE 11 plus) deck unit allows real-time interfacing between the deck and the underwater unit via a conductive wire, while the submersible SBE 17 (or SBE 17 plus) SEARAM plugs directly into the underwater unit and data are downloaded on recovery of the CTD. The combination of SBE 9 and SBE 17 or SBE 11 are termed SBE 917 or SBE 911, respectively, while the combinations of SBE 9 plus and SBE 17 plus or SBE 11 plus are termed SBE 917 plus or SBE 911 plus.

Specifications

Specifications for the SBE 9 plus underwater unit are listed below:

Parameter Range Initial accuracy Resolution at 24 Hz Response time
Temperature -5 to 35°C 0.001°C 0.0002°C 0.065 sec
Conductivity 0 to 7 S m-1 0.0003 S m-1 0.00004 S m-1 0.065 sec (pumped)
Pressure 0 to full scale (1400, 2000, 4200, 6800 or 10500 m) 0.015% of full scale 0.001% of full scale 0.015 sec

Further details can be found in the manufacturer's specification sheet.

BODC Processing

Reformatting

The data from KH12-4 arrived at BODC as 22 xlsx files which were reformatted to .csv in the first instance. Data were subsequently reformatted to BODC internal QXF format. The following table shows how the variables within the .csv files were mapped to the appropriate BODC parameter codes.

Originator's Parameter Name Units Description BODC Parameter Code Units Comments
PrDM dbar Pressure (spatial co-ordinate) exerted by the water body by profiling pressure sensor and corrected to read zero at sea level PRESPR01 dbar Calibrated before cruise by Sea-Bird Electronics Inc. but no dates given.
T090C °C Temperature of the water body by CTD or STD TEMPST01 °C Calibrated before cruise by Sea-Bird Electronics Inc. but no dates given
C0S/m S/m Electrical conductivity of the water body by CTD CNDCST01 S/m Calibrated before cruise by Sea-Bird Electronics Inc. but no dates given. No calibration against independant water samples.
Sbeox0ML/L ml l-1 Concentration of oxygen per unit volume of the water body by Sea-Bird SBE 43 sensor and no calibration against sample data DOXYSU01 µmol l-1 Calibrated before cruise by Sea-Bird Electronics Inc. but date unknown. No calibration against independant water samples. Values multipled by 44.66 for unit conversion to µmol l-1. Used on all casts except BD-4 and BD-12.
FlSP µg l-1 Concentration of chlorophyll-a per unit volume of the water body by in-situ chlorophyll fluorometer CPHLPR01 mg m-3 Calibrated before cruise by Chelsea Technologies Group Ltd. but date unknown. Used on all casts except BD-4 and BD-12.
Upoly0 ppb Concentration of coloured dissolved organic matter per unit volume of the water body by fluorometry CDOMZZ01 ppb Used on all casts except BD-4 and BD-12.
SeaTurbMtr FTU Turbidity of the water body by in-situ optical backscatter measurement and laboratory calibration against formazin TURBPR01 NTU Used on all casts except BD-4 and BD-12.
AltM Metres Height above bed in the water body AHSFZZ01 Metres Used only on station BD-12
SvDM Metres per second Sound velocity in the water body SVELXXXX Metres per second Used on all casts except BD-4 and BD-12. Derived from temperature and salinity by originator.
Sal00 Dimensionless Practical salinity of the water body by CTD and computation using UNESCO 1983 algorithm and NO calibration against independent measurements PSALCU01 Dimensionless No calibration against independent water samples.
Sigma-t00 kg m-3 Sigma-theta of the water body by CTD and computation from salinity and potential temperature using UNESCO algorithm SIGTPR01 kg m-3 Derived parameter - not transferred.
Potemp090C °C Potential temperature of the water body by computation using UNESCO 1983 algorithm POTMCV01 °C Derived parameter - not transferred.

BODC assigned each CTD event with a unique identifier (OID) based on the originator's event log. OID was assembled from the originator's station number.

Screening

Reformatted CTD data were visualised using the in-house graphical editor EDSERPLO. Quality control flags were applied to data as necessary.

Originator's Data Processing

Sampling Strategy

During the cruise two different CTD-systems were deployed.

  1. An SBE911plus CTD-system suitable for depths up to 6000m (20 stations).
  2. An SBE911plus CTD-system suitable for depths greater than 6000m, up to 10000m (2 stations)

A total of 22 casts were carried out during the cruise.

The CTD Carousel sampling (CTD-CMS) System

To avoid contamination, the frame and cable of the CTD-CMS system was made of titanium , and all zinc anodes on the Carousel frames (except for those on the CTD housings) were replaced by aluminum anodes, in order to avoid Zn contamination. Water samples were taken by triggering the Niskin-X bottles at appropriate depths while the system was coming up to the surface. The deepest sample was usually taken at a depth of approximately 10 meters above the bottom.

To further reduce contamination for the sampling, Niskin-X bottles were cleaned before the cruise by filling the bottles with 1.5% Extran MA01 (1 day), 0.1M HCl (pH=1, 1day), and Milli-Q water (more than 2 days), successively. Teflon spigots were pre-washed by soaking in 1% of Extran MA02 (1 day) and 1M HCl(1 day), and cleaned by heating in conc.HClO4:conc.H2SO4:conc.HNO3=1:1:1 mixture (120°C, 3 hrs), 6M HCl 25 (120°C, 3 hrs), and Milli-Q water (100°C, 3 hrs), successively. Viton O-rings were pre-washed by soaking in 1% of Extran MA02 (1 day) and 0.1M HCl (1 day), and cleaned by heating in 0.1M HCl (at 60°C, 12hrs), and Milli-Q water (at 68°C, 12 hrs).

Data Processing

There is no information available regarding the processing of the CTD sensors, except that the data were produced using Sea-Bird Electronics Inc. 'SEASOFT' software.

Field Calibrations

None of the CTD sensors were calibrated against independent water samples from the Niskin bottles.

Further details on the originators processing can be found in the cruise report.


Project Information

GEOTRACES

Introduction

GEOTRACES is an international programme sponsored by SCOR which aims to improve our understanding of biogeochemical cycles and large-scale distribution of trace elements and their isotopes (TEIs) in the marine environment. The global field programme started in 2009 and will run for at least a decade. Before the official launch of GEOTRACES, fieldwork was carried out as part of the International Polar Year (IPY)(2007-2009) where 14 cruises were connected to GEOTRACES.

GEOTRACES is expected to become the largest programme to focus on the chemistry of the oceans and will improve our understanding of past, present and future distributions of TEIs and their relationships to important global processes.

This initiative was prompted by the increasing recognition that TEIs are playing a crucial role as regulators and recorders of important biogeochemical and physical processes that control the structure and productivity of marine ecosystems, the dispersion of contaminants in the marine environment, the level of greenhouse gases in the atmosphere, and global climate.

Scientific Objectives

GEOTRACES mission is: To identify processes and quantify fluxes that control the distribution of key trace elements and isotopes in the ocean, and to establish the sensitivity of these distributions to changing environmental conditions.

Three overriding goals support the GEOTRACES mission

  • Determine ocean distributions of selected TEIs at all major ocean basins
  • Evaluate the sources, sinks, and internal cycling of these TEIs and thereby characterize more completely their global biogeochemical cycles
  • Provide a baseline distribution in the Polar Regions as reference for assessing past and future changes.

These goals will be pursued through complementary research strategies, including observations, experiments and modelling.

Fieldwork

The central component of GEOTRACES fieldwork will be a series of cruises spanning all Ocean basins see map below.

BODC image

Three types of cruise are required to meet the goals set out by GEOTRACES. These are

  • Section cruises - These will measure all the key parameters (see below) over the full depth of the water column. The sections were discussed and approved by the International GEOTRACES Scientific Steering Committee at the basin workshops.
  • Process Studies - These will investigate a particular process relevant to the cycling of trace metal and isotopes. They must follow the "Criteria for Establishing GEOTRACES Process Studies" and be approved by the International GEOTRACES Scientific Steering Committee.
  • Cruises collecting GEOTRACES compliant data - These will collect some trace element or isotope data. They must follow the GEOTRACES Intercalibration and Data Management protocols

IPY-GEOTRACES

The IPY-GEOTRACES programme comprised of 14 research cruises on ships from 7 nations; Australia, Canada, France, Germany, New Zealand, Japan and Russia. The cruises will not be classified in the same way as the full GEOTRACES programme since the intercalibration protocols and data management protocols had not been established before the start of the IPY. But IPY-GEOTRACES data will still be quality controlled by GDAC and in the majority of cases verified versus Intercalibration standards or protocols.

Key parameters

The key parameters as set out by the GEOTRACES science plan are as follows: Fe, Al, Zn, Mn, Cd, Cu; 15N, 13C; 230Th, 231Pa; Pb isotopes, Nd isotopes; stored sample, particles, aerosols.

Weblink:

http://www.bodc.ac.uk/geotraces/
http://www.geotraces.org/


Data Activity or Cruise Information

Cruise

Cruise Name KH12-04 (GP02)
Departure Date 2012-08-23
Arrival Date 2012-10-03
Principal Scientist(s)Toshitaka Gamo (University of Tokyo, Atmosphere and Ocean Research Institute)
Ship Hakuho Maru

Complete Cruise Metadata Report is available here


Fixed Station Information


No Fixed Station Information held for the Series


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification