Search the data

Metadata Report for BODC Series Reference Number 1877236


Metadata Summary

Data Description

Data Category CTD or STD cast
Instrument Type
NameCategories
Sea-Bird SBE 43 Dissolved Oxygen Sensor  dissolved gas sensors
Sea-Bird SBE 911plus CTD  CTD; water temperature sensor; salinity sensor
Tritech PA-200 Altimeter  altimeters
Sea-Bird SBE 3plus (SBE 3P) temperature sensor  water temperature sensor
Sea-Bird SBE 4C conductivity sensor  salinity sensor
Chelsea Technologies Group Aquatracka III fluorometer  fluorometers
Biospherical Instruments QCP-2350 [underwater] PAR sensor  radiometers
Instrument Mounting lowered unmanned submersible
Originating Country United Kingdom
Originator Dr Sophie Fielding
Originating Organization British Antarctic Survey
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) -
 

Data Identifiers

Originator's Identifier JR17002_CTD004.2DB
BODC Series Reference 1877236
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 2018-01-01 12:29
End Time (yyyy-mm-dd hh:mm) -
Nominal Cycle Interval 2.0 decibars
 

Spatial Co-ordinates

Latitude 52.36050 S ( 52° 21.6' S )
Longitude 49.07867 W ( 49° 4.7' W )
Positional Uncertainty 0.0 to 0.01 n.miles
Minimum Sensor or Sampling Depth 0.99 m
Maximum Sensor or Sampling Depth 54.51 m
Minimum Sensor or Sampling Height 3153.02 m
Maximum Sensor or Sampling Height 3206.54 m
Sea Floor Depth 3207.53 m
Sea Floor Depth Source BUDS
Sensor or Sampling Distribution Variable common depth - All sensors are grouped effectively at the same depth, but this depth varies significantly during the series
Sensor or Sampling Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
Sea Floor Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
 

Parameters

BODC CODERankUnitsTitle
ACYCAA011DimensionlessSequence number
AHSFZZ011MetresHeight (spatial coordinate) relative to bed surface in the water body
ATTNMR011per metreAttenuation (red light wavelength) per unit length of the water body by 20 or 25cm path length transmissometer
CNDCST011Siemens per metreElectrical conductivity of the water body by CTD
CPHLPR011Milligrams per cubic metreConcentration of chlorophyll-a {chl-a CAS 479-61-8} per unit volume of the water body [particulate >unknown phase] by in-situ chlorophyll fluorometer
DOXYZZ011Micromoles per litreConcentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by in-situ sensor
IRRDUV011MicroEinsteins per square metre per secondDownwelling vector irradiance as photons of electromagnetic radiation (PAR wavelengths) in the water body by cosine-collector radiometer
OXYSZZ011PercentSaturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase]
POTMCV011Degrees CelsiusPotential temperature of the water body by computation using UNESCO 1983 algorithm
PRESPR011DecibarsPressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level
PSALST011DimensionlessPractical salinity of the water body by CTD and computation using UNESCO 1983 algorithm
SIGTPR011Kilograms per cubic metreSigma-theta of the water body by CTD and computation from salinity and potential temperature using UNESCO algorithm
TEMPST011Degrees CelsiusTemperature of the water body by CTD or STD

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database

RRS James Clark Ross JR17002 CTD Data Quality Report.

Data were screened following BODC procedures. Altimeter data when values were equal or above 100. The altimeter only displays valid information when it is 100m above the seafloor. Sporadic values were also flagged M as they were considered improbable.


Data Access Policy

Open Data supplied by Natural Environment Research Council (NERC)

You must always use the following attribution statement to acknowledge the source of the information: "Contains data supplied by Natural Environment Research Council."


Narrative Documents

Sea-Bird Dissolved Oxygen Sensor SBE 43 and SBE 43F

The SBE 43 is a dissolved oxygen sensor designed for marine applications. It incorporates a high-performance Clark polarographic membrane with a pump that continuously plumbs water through it, preventing algal growth and the development of anoxic conditions when the sensor is taking measurements.

Two configurations are available: SBE 43 produces a voltage output and can be incorporated with any Sea-Bird CTD that accepts input from a 0-5 volt auxiliary sensor, while the SBE 43F produces a frequency output and can be integrated with an SBE 52-MP (Moored Profiler CTD) or used for OEM applications. The specifications below are common to both.

Specifications

Housing Plastic or titanium
Membrane

0.5 mil- fast response, typical for profile applications

1 mil- slower response, typical for moored applications

Depth rating

600 m (plastic) or 7000 m (titanium)

10500 m titanium housing available on request

Measurement range 120% of surface saturation
Initial accuracy 2% of saturation
Typical stability 0.5% per 1000 h

Further details can be found in the manufacturer's specification sheet.

RRS James Clark Ross JR17002 CTD Instrumentation

A Sea-Bird 911 plus CTD system was used on cruise JR17002. This was mounted on a SBE-32 carousel water sampler holding 24 12-litre Niskin bottles. The CTD was fitted with the following scientific sensors:

Sensor Serial Number Calibration Date Comments
Sea-Bird SBE 911plus CTD 0458/0707    
Sea-Bird SBE 3plus (SBE 3P) temperature sensor 032705 27-May-2017 Primary sensor
Sea-Bird SBE 3plus (SBE 3P) temperature sensor 03P5042 25-May-2017 Secondary sensor
Sea-Bird SBE 4C conductivity sensor* 042222 24-May-2017 Primary sensor
Sea-Bird SBE 4C conductivity sensor 042255 24-May-2017 Secondary sensor
Sea-Bird SBE 43 Dissolved Oxygen Sensor 432291 20-May-2017  
Sea-Bird SBE 35 Thermometer 3527735-0024    
Paroscientific 410K Pressure Transducer 0707 23-May-2017  
WETLabs C-Star transmissometer 396DR    
Biospherical QCD-905L underwater PAR sensor 70688 20-Jun-2017  
Chelsea Technologies Group Aquatracka III fluorometer 097324001 19-May-2017  
Tritech PA-200 Altimeter ** 10127.244740    

The CTD frame was also equiped with an LADCP, SN 14897.

*- The Conductivity sensor was replaced after the first cast, the initial sensor had the SN 043488.

**- The Altimeter was replaced after the first cast, the initial sensor had the SN 27001

Sea-Bird Electronics SBE 911 and SBE 917 series CTD profilers

The SBE 911 and SBE 917 series of conductivity-temperature-depth (CTD) units are used to collect hydrographic profiles, including temperature, conductivity and pressure as standard. Each profiler consists of an underwater unit and deck unit or SEARAM. Auxiliary sensors, such as fluorometers, dissolved oxygen sensors and transmissometers, and carousel water samplers are commonly added to the underwater unit.

Underwater unit

The CTD underwater unit (SBE 9 or SBE 9 plus) comprises a protective cage (usually with a carousel water sampler), including a main pressure housing containing power supplies, acquisition electronics, telemetry circuitry, and a suite of modular sensors. The original SBE 9 incorporated Sea-Bird's standard modular SBE 3 temperature sensor and SBE 4 conductivity sensor, and a Paroscientific Digiquartz pressure sensor. The conductivity cell was connected to a pump-fed plastic tubing circuit that could include auxiliary sensors. Each SBE 9 unit was custom built to individual specification. The SBE 9 was replaced in 1997 by an off-the-shelf version, termed the SBE 9 plus, that incorporated the SBE 3 plus (or SBE 3P) temperature sensor, SBE 4C conductivity sensor and a Paroscientific Digiquartz pressure sensor. Sensors could be connected to a pump-fed plastic tubing circuit or stand-alone.

Temperature, conductivity and pressure sensors

The conductivity, temperature, and pressure sensors supplied with Sea-Bird CTD systems have outputs in the form of variable frequencies, which are measured using high-speed parallel counters. The resulting count totals are converted to numeric representations of the original frequencies, which bear a direct relationship to temperature, conductivity or pressure. Sampling frequencies for these sensors are typically set at 24 Hz.

The temperature sensing element is a glass-coated thermistor bead, pressure-protected inside a stainless steel tube, while the conductivity sensing element is a cylindrical, flow-through, borosilicate glass cell with three internal platinum electrodes. Thermistor resistance or conductivity cell resistance, respectively, is the controlling element in an optimized Wien Bridge oscillator circuit, which produces a frequency output that can be converted to a temperature or conductivity reading. These sensors are available with depth ratings of 6800 m (aluminium housing) or 10500 m (titanium housing). The Paroscientific Digiquartz pressure sensor comprises a quartz crystal resonator that responds to pressure-induced stress, and temperature is measured for thermal compensation of the calculated pressure.

Additional sensors

Optional sensors for dissolved oxygen, pH, light transmission, fluorescence and others do not require the very high levels of resolution needed in the primary CTD channels, nor do these sensors generally offer variable frequency outputs. Accordingly, signals from the auxiliary sensors are acquired using a conventional voltage-input multiplexed A/D converter (optional). Some Sea-Bird CTDs use a strain gauge pressure sensor (Senso-Metrics) in which case their pressure output data is in the same form as that from the auxiliary sensors as described above.

Deck unit or SEARAM

Each underwater unit is connected to a power supply and data logging system: the SBE 11 (or SBE 11 plus) deck unit allows real-time interfacing between the deck and the underwater unit via a conductive wire, while the submersible SBE 17 (or SBE 17 plus) SEARAM plugs directly into the underwater unit and data are downloaded on recovery of the CTD. The combination of SBE 9 and SBE 17 or SBE 11 are termed SBE 917 or SBE 911, respectively, while the combinations of SBE 9 plus and SBE 17 plus or SBE 11 plus are termed SBE 917 plus or SBE 911 plus.

Specifications

Specifications for the SBE 9 plus underwater unit are listed below:

Parameter Range Initial accuracy Resolution at 24 Hz Response time
Temperature -5 to 35°C 0.001°C 0.0002°C 0.065 sec
Conductivity 0 to 7 S m-1 0.0003 S m-1 0.00004 S m-1 0.065 sec (pumped)
Pressure 0 to full scale (1400, 2000, 4200, 6800 or 10500 m) 0.015% of full scale 0.001% of full scale 0.015 sec

Further details can be found in the manufacturer's specification sheet.

Chelsea Technologies Group Aquatracka MKIII fluorometer

The Chelsea Technologies Group Aquatracka MKIII is a logarithmic response fluorometer. Filters are available to enable the instrument to measure chlorophyll, rhodamine, fluorescein and turbidity.

It uses a pulsed (5.5 Hz) xenon light source discharging along two signal paths to eliminate variations in the flashlamp intensity. The reference path measures the intensity of the light source whilst the signal path measures the intensity of the light emitted from the specimen under test. The reference signal and the emitted light signals are then applied to a ratiometric circuit. In this circuit, the ratio of returned signal to reference signal is computed and scaled logarithmically to achieve a wide dynamic range. The logarithmic conversion accuracy is maintained at better than one percent of the reading over the full output range of the instrument.

Two variants of the instrument are available, both manufactured in titanium, capable of operating in depths from shallow water down to 2000 m and 6000 m respectively. The optical characteristics of the instrument in its different detection modes are visible below:

Excitation Chlorophyll a Rhodamine Fluorescein Turbidity
Wavelength (nm) 430 500 485 440*
Bandwidth (nm) 105 70 22 80*
Emission Chlorophyll a Rhodamine Fluorescein Turbidity
Wavelength (nm) 685 590 530 440*
Bandwidth (nm) 30 45 30 80*

* The wavelengths for the turbidity filters are customer selectable but must be in the range 400 to 700 nm. The same wavelength is used in the excitation path and the emission path.

The instrument measures chlorophyll a, rhodamine and fluorescein with a concentration range of 0.01 µg l-1 to 100 µg l-1. The concentration range for turbidity is 0.01 to 100 FTU (other wavelengths are available on request).

The instrument accuracy is ± 0.02 µg l-1 (or ± 3% of the reading, whichever is greater) for chlorophyll a, rhodamine and fluorescein. The accuracy for turbidity, over a 0 - 10 FTU range, is ± 0.02 FTU (or ± 3% of the reading, whichever is greater).

Further details are available from the Aquatracka MKIII specification sheet.

Biospherical Instruments QCP-2350 [underwater] PAR sensor

A cosine-corrected PAR quantum irradiance profiling sensor. For use in underwater applications with 24 bit ADC systems. Measures light available for photosynthesis on a flat surface. Operation is by a single channel compressed analog output voltage that is proportional to the log of incident PAR (400-700 nm) irradiance. The sensor is designed for operation in waters to depths of up to 2,000 m (standard) or 6,800 m (optional).

For more information, please see this document: https://www.bodc.ac.uk/data/documents/nodb/pdf/Biospherical_QCP2300_QCP2350_Apr2014.pdf

Tritech Digital Precision Altimeter PA200

This altimeter is a sonar ranging device that gives the height above the sea bed when mounted vertically. When mounted in any other attitude the sensor provides a subsea distance. It can be configured to operate on its own or under control from an external unit and can be supplied with simultaneous analogue and digital outputs, allowing them to interface to PC devices, data loggers, telemetry systems and multiplexers.

These instruments can be supplied with different housings, stainless steel, plastic and aluminum, which will limit the depth rating. There are three models available: the PA200-20S, PA200-10L and the PA500-6S, whose transducer options differ slightly.

Specifications

Transducer options PA200-20S P200-10L PA500-6S
Frequency (kHz) 200 200 500
Beamwidth (°) 20 Conical 10 included conical beam 6 Conical
Operating range

1 to 100 m

0.7 to 50 m

-

0.3 to 50 m

0.1 to 10 m

Common specifications are presented below

Digital resolution 1 mm
Analogue resolution 0.25% of range
Depth rating 700 , 2000, 4000 and 6800 m
Operating temperature -10 to 40°C

Further details can be found in the manufacturer's specification sheet.

RRS James Clark Ross JR17002 CTD BODC Processing

Data were submitted to BODC in matlab format with files containing the downcast. The data were transferred into BODC's internal NetCDf format and original variables were mapped to the appropiate BODC codes, as follows:

Originator's parameter Origingator's Units BODC code BODC Units Comments
temp1 deg C TEMPST01 deg C  
sal1   PSALST01    
cond1 S m-1 CNDCST01 S m-1  
oxy_umol_l µmol l-1 DOXYZZ01 µmol l-1  
press db PRESPR01 db  
BeamAtt 1 m-1 ATTNMR01 1 m-1  
par   IRRDUV01 µE m-2 s -1 Equivalent units.
fluor_ug_l µg l-1 CPHLPR01 mg m-3 Equivalent units.
alt m AHSFZZ01 m -
- - OXYSZZ01 % BODC derived parameter using standard algorithm.
- - POTMCV01 deg C BODC derived parameter using standard algorithm.
- - SIGTPR01 kg m-3 BODC derived parameter using standard algorithm.

Duplicate channels for Temperature, Salinity and Conductivity were sent by the originator. These data have been transferred but as there are no significant differences between primary and secondary sensor data, they are not included in the final file. Data from the duplicate sensors are available upon request.

Potential Temperature (POTMCV01), Sigma-theta (SIGTPR01) and oxygen saturation (OXYSZZ01) have been re-derived and transferred to the internal NetCDF file following standard procedures.

Screening of data files were then completed using the in-house software EDSERPLO, which allows a visual inspection to take place of the data values and to flag any missing data or obvious spikes in the data.

RRS James Clark Ross JR17002 CTD Data Originator's Processing

Originator's Sampling

A total of 19 CTDs were deployed at various locations on the Western Core Box area. Data were collected at 24Hz and logged via the deck unit to a PC running Seasave, version 7.21d (Sea-Bird Electronics, Inc.), which allows real-time viewing of the data. The procedure was to start data logging, deploy the CTD, then stop the instrument at 10m wireout, where the CTD package was left for at least two minutes to allow the seawater-activated pumps to switch on and the sensors to equilibrate with ambient conditions. The pumps are typically expected to switch on 60 seconds after the instrument is deployed.

After the 10m soak, the CTD was raised to as close to the surface as wave and swell condition allowed and then lowered to within 10m of the seabed. Bottles were fired on the upcast, where the procedure was to stop the CTD winch, hold the package in situ for a few seconds to allow sensors to equilibrate, and then fire a bottle. The sensor averages these readings to produce one value for each bottle fire. Short times between firing pairs of bottles sometimes led to no SBE35 readings for the second bottle of the pair. Bottle firing depths were determined by sampling requirements. Basic CTD processing was undertaken using the SBE software, including the modules listed below:

  • DATCNV - used to read in the raw CTD data file (.hex) which contained the data in engineering units and apply calibrations as appropriate through the instrument configurations (.con) file
  • CENTRAL THERMAL MASS - used alpha = 0.03 and 1/beta = 7 values to correct for conductivity errors induced by the transfer of heat from the conductivity cell to the seawater

Project Information


No Project Information held for the Series

Data Activity or Cruise Information

Cruise

Cruise Name JR17002
Departure Date 2017-12-23
Arrival Date 2018-01-22
Principal Scientist(s)Clara Manno (British Antarctic Survey)
Ship RRS James Clark Ross

Complete Cruise Metadata Report is available here


Fixed Station Information


No Fixed Station Information held for the Series


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification