Metadata Report for BODC Series Reference Number 2210089


Metadata Summary

Data Description

Data Category CTD or STD cast
Instrument Type
NameCategories
SeaTech transmissometer  transmissometers
Sea-Bird SBE 43 Dissolved Oxygen Sensor  dissolved gas sensors
Sea-Bird SBE 911plus CTD  CTD; water temperature sensor; salinity sensor
Seapoint chlorophyll fluorometer  fluorometers
WET Labs {Sea-Bird WETLabs} ECO FLNTU combined fluorometer and turbidity sensor  fluorometers; optical backscatter sensors
Sea-Bird SBE 3plus (SBE 3P) temperature sensor  water temperature sensor
Sea-Bird SBE 4C conductivity sensor  salinity sensor
Instrument Mounting lowered unmanned submersible
Originating Country United States
Originator Dr Mak Saito
Originating Organization Woods Hole Oceanographic Institution Department of Marine Chemistry and Geochemistry
Processing Status QC in progress
Online delivery of data Download not available
Project(s) GEOTRACES
 

Data Identifiers

Originator's Identifier GPC03_CTD15
BODC Series Reference 2210089
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 2011-10-22 13:03
End Time (yyyy-mm-dd hh:mm) -
Nominal Cycle Interval 2.0 decibars
 

Spatial Co-ordinates

Latitude 15.00000 S ( 15° 0.0' S )
Longitude 170.00000 W ( 170° 0.0' W )
Positional Uncertainty 0.0 to 0.01 n.miles
Minimum Sensor or Sampling Depth 3.01 m
Maximum Sensor or Sampling Depth 991.0 m
Minimum Sensor or Sampling Height 3833.05 m
Maximum Sensor or Sampling Height 4821.04 m
Sea Floor Depth 4824.05 m
Sea Floor Depth Source GEBCO1901
Sensor or Sampling Distribution Variable common depth - All sensors are grouped effectively at the same depth, but this depth varies significantly during the series
Sensor or Sampling Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
Sea Floor Depth Datum Unspecified -
 

Parameters

BODC CODERankUnitsTitle
ACYCAA011DimensionlessSequence number
CPHLPR011Milligrams per cubic metreConcentration of chlorophyll-a {chl-a CAS 479-61-8} per unit volume of the water body [particulate >unknown phase] by in-situ chlorophyll fluorometer
DOXMZZXX1Micromoles per kilogramConcentration of oxygen {O2 CAS 7782-44-7} per unit mass of the water body [dissolved plus reactive particulate phase]
PRESPR011DecibarsPressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level
PSALST011DimensionlessPractical salinity of the water body by CTD and computation using UNESCO 1983 algorithm
TEMPST011Degrees CelsiusTemperature of the water body by CTD or STD

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database


Data Access Policy

GEOTRACES - data access conditions

Access to this data is currently restricted and it is not available via BODC's normal delivery mechanisms.

GEOTRACES data are published via the GEOTRACES IDP, available at:


Narrative Documents

Sea-Bird Dissolved Oxygen Sensor SBE 43 and SBE 43F

The SBE 43 is a dissolved oxygen sensor designed for marine applications. It incorporates a high-performance Clark polarographic membrane with a pump that continuously plumbs water through it, preventing algal growth and the development of anoxic conditions when the sensor is taking measurements.

Two configurations are available: SBE 43 produces a voltage output and can be incorporated with any Sea-Bird CTD that accepts input from a 0-5 volt auxiliary sensor, while the SBE 43F produces a frequency output and can be integrated with an SBE 52-MP (Moored Profiler CTD) or used for OEM applications. The specifications below are common to both.

Specifications

Housing Plastic or titanium
Membrane

0.5 mil- fast response, typical for profile applications

1 mil- slower response, typical for moored applications

Depth rating

600 m (plastic) or 7000 m (titanium)

10500 m titanium housing available on request

Measurement range 120% of surface saturation
Initial accuracy 2% of saturation
Typical stability 0.5% per 1000 h

Further details can be found in the manufacturer's specification sheet.

KM1128 CTD Instrumentation

The CTD was fitted with the following sensors:

Sensor Serial Number Calibration Date Comments
Sea-Bird SBE 911plus CTD - - -
Sea-Bird SBE 3plus (SBE 3P) temperature sensor - - -
Sea-Bird SBE 4C conductivity sensor - - -
Sea-Bird SBE 43 Dissolved Oxygen Sensor - - -
Seapoint chlorophyll fluorometer - - -
WET Labs {Sea-Bird WETLabs} ECO FLNTU combined fluorometer and turbidity sensor - - -
SeaTech transmissometer - - -

Some information is unavailable.

Sea-Bird Electronics SBE 911 and SBE 917 series CTD profilers

The SBE 911 and SBE 917 series of conductivity-temperature-depth (CTD) units are used to collect hydrographic profiles, including temperature, conductivity and pressure as standard. Each profiler consists of an underwater unit and deck unit or SEARAM. Auxiliary sensors, such as fluorometers, dissolved oxygen sensors and transmissometers, and carousel water samplers are commonly added to the underwater unit.

Underwater unit

The CTD underwater unit (SBE 9 or SBE 9 plus) comprises a protective cage (usually with a carousel water sampler), including a main pressure housing containing power supplies, acquisition electronics, telemetry circuitry, and a suite of modular sensors. The original SBE 9 incorporated Sea-Bird's standard modular SBE 3 temperature sensor and SBE 4 conductivity sensor, and a Paroscientific Digiquartz pressure sensor. The conductivity cell was connected to a pump-fed plastic tubing circuit that could include auxiliary sensors. Each SBE 9 unit was custom built to individual specification. The SBE 9 was replaced in 1997 by an off-the-shelf version, termed the SBE 9 plus, that incorporated the SBE 3 plus (or SBE 3P) temperature sensor, SBE 4C conductivity sensor and a Paroscientific Digiquartz pressure sensor. Sensors could be connected to a pump-fed plastic tubing circuit or stand-alone.

Temperature, conductivity and pressure sensors

The conductivity, temperature, and pressure sensors supplied with Sea-Bird CTD systems have outputs in the form of variable frequencies, which are measured using high-speed parallel counters. The resulting count totals are converted to numeric representations of the original frequencies, which bear a direct relationship to temperature, conductivity or pressure. Sampling frequencies for these sensors are typically set at 24 Hz.

The temperature sensing element is a glass-coated thermistor bead, pressure-protected inside a stainless steel tube, while the conductivity sensing element is a cylindrical, flow-through, borosilicate glass cell with three internal platinum electrodes. Thermistor resistance or conductivity cell resistance, respectively, is the controlling element in an optimized Wien Bridge oscillator circuit, which produces a frequency output that can be converted to a temperature or conductivity reading. These sensors are available with depth ratings of 6800 m (aluminium housing) or 10500 m (titanium housing). The Paroscientific Digiquartz pressure sensor comprises a quartz crystal resonator that responds to pressure-induced stress, and temperature is measured for thermal compensation of the calculated pressure.

Additional sensors

Optional sensors for dissolved oxygen, pH, light transmission, fluorescence and others do not require the very high levels of resolution needed in the primary CTD channels, nor do these sensors generally offer variable frequency outputs. Accordingly, signals from the auxiliary sensors are acquired using a conventional voltage-input multiplexed A/D converter (optional). Some Sea-Bird CTDs use a strain gauge pressure sensor (Senso-Metrics) in which case their pressure output data is in the same form as that from the auxiliary sensors as described above.

Deck unit or SEARAM

Each underwater unit is connected to a power supply and data logging system: the SBE 11 (or SBE 11 plus) deck unit allows real-time interfacing between the deck and the underwater unit via a conductive wire, while the submersible SBE 17 (or SBE 17 plus) SEARAM plugs directly into the underwater unit and data are downloaded on recovery of the CTD. The combination of SBE 9 and SBE 17 or SBE 11 are termed SBE 917 or SBE 911, respectively, while the combinations of SBE 9 plus and SBE 17 plus or SBE 11 plus are termed SBE 917 plus or SBE 911 plus.

Specifications

Specifications for the SBE 9 plus underwater unit are listed below:

Parameter Range Initial accuracy Resolution at 24 Hz Response time
Temperature -5 to 35°C 0.001°C 0.0002°C 0.065 sec
Conductivity 0 to 7 S m-1 0.0003 S m-1 0.00004 S m-1 0.065 sec (pumped)
Pressure 0 to full scale (1400, 2000, 4200, 6800 or 10500 m) 0.015% of full scale 0.001% of full scale 0.015 sec

Further details can be found in the manufacturer's specification sheet.

Seapoint Chlorophyll Fluorometer

The Seapoint Chlorophyll Fluorometer (SCF) is a low power instrument for in situ measurements of chlorophyll a. The SCF uses modulated blue LED lamps and a blue excitation filter to excite chlorophyll a. The fluorescent light emitted by the chlorophyll a passes through a red emission filter and is detected by a silicon photodiode. The low level signal is then processed using synchronous demodulation circuitry which generates an output voltage proportional to chlorophyll a concentration. The SCF may be operated with or without a pump.

Sensor specifications, current at August 2006, are given in the table below. More information can be found at the manufacturer's web site.

Sensor Specifications

Power requirements 8 - 20 VDC, 15 mA avg., 27 mA pk.
Output 0 - 5.0 VDC
Output Time Constant 0.1 sec.
Power-up transient period < 1 sec.
Excitation Wavelength 470 nm CWL, 30 nm FWHM
Emission Wavelength 685 nm CWL, 30 nm FWHM
Sensing Volume 340 mm3
Minimum Detectable Level 0.02 µg l-1

  Gain Sensitivity, V µg-1 l-1 Range, µg l-1
Sensitivity/Range 30x
10x
3x
1x
1.0
0.33
0.1
0.033
5
15
50
150

WETLabs ECO FLNTU fluorescence and turbidity sensor

The Environmental Characterization Optics (ECO) Fluorometer and Turbidity (FLNTU) sensor is a dual wavelength, single-angle instrument that simultaneously determines chlorophyll fluorescence and turbidity. It is easily integrated in CTD packages and provides a reliable turbidity measurement that is not affected by Colored Dissolved Organic Matter (CDOM) concentration.

The FLNTU can operate continuously or periodically and has two different types of connectors to output the data. There are 5 other models that operate the same way as this instrument but have slight differences, as stated below:

  • FLNTU(RT) - has an analog an RS-232 serial output and operates continuously, when power is supplied
  • FLNTU(RT)D - similar to the FLNTU(RT) but has a depth rating of 6000 m
  • FLNTUB - has internal batteries for autonomous operation
  • FLNTUS - has an integrated anti-fouling bio-wiper
  • FLNTUSB - has the same characteristics as the FLNTUS but with internal batteries for autonomous operation

Specifications

Temperature range 0 to 30°C
Depth rating

600 m (standard)

6000 m (deep)

Turbidity
Wavelength 700 nm
Sensitivity 0.01 NTU
Typical range 0.01 to 25 NTU
Fluorescence
Wavelength 470 nm (excitation), 695 nm (emission)
Sensitivity 0.01 µg L-1
Typical range 0.01 to 50 µg L-1
Linearity 99% R2

Further details can be found in the manufacturer's specification sheet.

SeaTech Transmissometer

Introduction

The transmissometer is designed to accurately measure the the amount of light transmitted by a modulated Light Emitting Diode (LED) through a fixed-length in-situ water column to a synchronous detector.

Specifications

  • Water path length: 5 cm (for use in turbid waters) to 1 m (for use in clear ocean waters).
  • Beam diameter: 15 mm
  • Transmitted beam collimation: <3 milliradians
  • Receiver acceptance angle (in water): <18 milliradians
  • Light source wavelength: usually (but not exclusively) 660 nm (red light)

Notes

The instrument can be interfaced to Aanderaa RCM7 current meters. This is achieved by fitting the transmissometer in a slot cut into a customized RCM4-type vane.

A red LED (660 nm) is used for general applications looking at water column sediment load. However, green or blue LEDs can be fitted for specilised optics applications. The light source used is identified by the BODC parameter code.

Further details can be found in the manufacturer's Manual.

Downcast CTD profiles for Cruise KM1128 (GPc03)

Sampling Strategy

A total of 8 CTD casts were carried out during cruise KM1128, on board the Kilo Moana, using a stainless steel CTD frame. The cruise surveyed GEOTRACES section GPc03.

Originator's Data Processing Procedures

The entire rosette, including the CTD sensor package, came free from the hydrowire at Station 2 and was never recovered. The CTD and sensors were replaced by a new package at Station 5.

Data were processed using SeaBird Data Processing software, version 7.21f.

KM1128 Cruise report

Further information can be found in the KM1128 Cruise report.

BODC Data Processing Procedures

Data received were converted to the BODC internal format (a netCDF subset) and then mapped to GEOTRACES parameter names. A parameter mapping table is provided below:

Originator's Variable Originator's Units BODC Parameter Code BODC Units GEOTRACES Code GEOTRACES Units Comments
xmiss % ATTNZZ01 % CTDBEAMCP_T_VALUE_SENSOR 1/m -
prDM decibar PRESPR01 decibar CTDPRS_T_VALUE_SENSOR decibar -
t090C °C TEMPST01 °C CTDTMP_T_VALUE_SENSOR °C -
sal00 PSU PSALST01 dimensionless CTDSAL_D_CONC_SENSOR PSS-78 Units are equivalent.
sbeox0mM_kg µmol/kg DOXMZZXX µmol/kg CTDOXY_D_CONC_SENSOR µmol/kg -
flSP/upoly0 µg/l CPHLPR01 mg/m3 CTDCHLA_T_CONC_SENSOR mg/m3 Units are equivalent.

Following transfer the data were screened using BODC in-house visualisation software. Suspect data values were assigned the appropriate BODC data quality flag. Missing data values, where present, were changed to the missing data value and assigned a BODC data quality flag. These flags are provided in the IDP as SeaDataNet flags.

Data Quality Report

Surface (0-10m) oxygen data are suspect.


Project Information

GEOTRACES

Introduction

GEOTRACES is an international programme sponsored by SCOR which aims to improve our understanding of biogeochemical cycles and large-scale distribution of trace elements and their isotopes (TEIs) in the marine environment. The global field programme started in 2009 and will run for at least a decade. Before the official launch of GEOTRACES, fieldwork was carried out as part of the International Polar Year (IPY)(2007-2009) where 14 cruises were connected to GEOTRACES.

GEOTRACES is expected to become the largest programme to focus on the chemistry of the oceans and will improve our understanding of past, present and future distributions of TEIs and their relationships to important global processes.

This initiative was prompted by the increasing recognition that TEIs are playing a crucial role as regulators and recorders of important biogeochemical and physical processes that control the structure and productivity of marine ecosystems, the dispersion of contaminants in the marine environment, the level of greenhouse gases in the atmosphere, and global climate.

Scientific Objectives

GEOTRACES mission is: To identify processes and quantify fluxes that control the distribution of key trace elements and isotopes in the ocean, and to establish the sensitivity of these distributions to changing environmental conditions.

Three overriding goals support the GEOTRACES mission

  • Determine ocean distributions of selected TEIs at all major ocean basins
  • Evaluate the sources, sinks, and internal cycling of these TEIs and thereby characterize more completely their global biogeochemical cycles
  • Provide a baseline distribution in the Polar Regions as reference for assessing past and future changes.

These goals will be pursued through complementary research strategies, including observations, experiments and modelling.

Fieldwork

The central component of GEOTRACES fieldwork will be a series of cruises spanning all Ocean basins see map below.

BODC image

Three types of cruise are required to meet the goals set out by GEOTRACES. These are

  • Section cruises - These will measure all the key parameters (see below) over the full depth of the water column. The sections were discussed and approved by the International GEOTRACES Scientific Steering Committee at the basin workshops.
  • Process Studies - These will investigate a particular process relevant to the cycling of trace metal and isotopes. They must follow the "Criteria for Establishing GEOTRACES Process Studies" and be approved by the International GEOTRACES Scientific Steering Committee.
  • Cruises collecting GEOTRACES compliant data - These will collect some trace element or isotope data. They must follow the GEOTRACES Intercalibration and Data Management protocols

IPY-GEOTRACES

The IPY-GEOTRACES programme comprised of 14 research cruises on ships from 7 nations; Australia, Canada, France, Germany, New Zealand, Japan and Russia. The cruises will not be classified in the same way as the full GEOTRACES programme since the intercalibration protocols and data management protocols had not been established before the start of the IPY. But IPY-GEOTRACES data will still be quality controlled by GDAC and in the majority of cases verified versus Intercalibration standards or protocols.

Key parameters

The key parameters as set out by the GEOTRACES science plan are as follows: Fe, Al, Zn, Mn, Cd, Cu; 15N, 13C; 230Th, 231Pa; Pb isotopes, Nd isotopes; stored sample, particles, aerosols.

Weblink:

http://www.bodc.ac.uk/geotraces/
http://www.geotraces.org/


Data Activity or Cruise Information

Cruise

Cruise Name KM1128 (GPc03, METZYME)
Departure Date 2011-10-01
Arrival Date 2011-10-25
Principal Scientist(s)Carl H Lamborg (Woods Hole Oceanographic Institution Department of Marine Chemistry and Geochemistry)
Ship RV Kilo Moana

Complete Cruise Metadata Report is available here


Fixed Station Information


No Fixed Station Information held for the Series


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification