Metadata Summary

Data Description

Data Category CTD or STD cast
Instrument Type
NameCategories
Falmouth Scientific Instruments Integrated CTD Profiler  CTD; water temperature sensor; salinity sensor
Instrument Mounting research vessel
Originating Country United Kingdom
Originator -
Originating Organization Ministry of Agriculture, Fisheries and Food Lowestoft Fisheries Laboratory (now Centre for Environment, Fisheries and Aquaculture Science Lowestoft Laboratory)
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) -
 

Data Identifiers

Originator's Identifier CI10/95/118
BODC Series Reference 488822
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 1995-12-07 18:30
End Time (yyyy-mm-dd hh:mm) -
Nominal Cycle Interval 1.0 metres
 

Spatial Co-ordinates

Latitude 54.35700 N ( 54° 21.4' N )
Longitude 3.70770 W ( 3° 42.5' W )
Positional Uncertainty Unspecified
Minimum Sensor or Sampling Depth 1.0 m
Maximum Sensor or Sampling Depth 26.8 m
Minimum Sensor or Sampling Height 2.2 m
Maximum Sensor or Sampling Height 28.0 m
Sea Floor Depth 29.0 m
Sea Floor Depth Source -
Sensor or Sampling Distribution Variable common depth - All sensors are grouped effectively at the same depth, but this depth varies significantly during the series
Sensor or Sampling Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
Sea Floor Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
 

Parameters

BODC CODERankUnitsTitle
ACYCAA011DimensionlessSequence number
ATTNMR011per metreAttenuation (red light wavelength) per unit length of the water body by 20 or 25cm path length transmissometer
PRESPR011DecibarsPressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level
PSALPR011DimensionlessPractical salinity of the water body by conductivity cell and computation using UNESCO 1983 algorithm
TEMPST011Degrees CelsiusTemperature of the water body by CTD or STD
TSEDTR011Milligrams per litreConcentration of suspended particulate material {SPM} per unit volume of the water body [particulate >unknown phase] by in-situ optical attenuance measurement and calibration against sample data

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database


Data Access Policy

Public domain data

These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.

The recommended acknowledgment is

"This study uses data from the data source/organisation/programme, provided by the British Oceanographic Data Centre and funded by the funding body."


Narrative Documents

Falmouth Scientific Integrated CTD (ICTD) Profiler

The FSI ICTD is designed to collect high precision conductivity, temperature and pressure data with self calibrating electronics. This instrument can support five primary sensors (including up to three temperature sensors) and can be coupled with a water bottle sampler. The ICTD is equipped with a titanium housing rated to 7000 m and has a sampling rate of 32 Hz.

Three temperature sensors are available: primary platinum, redundant platinum and exposed thermistor. Any combination of these can be used in the primary channels. The instrument also has multiple RS-232 serial inputs for a variety of sensors including: ADCP, Benthos PSA-916 Altimeter and WetLabs SAFire. There are an additional eight DC input channels that can support virtually any sensor that has a DC output.

Specifications:

Parameter Conductivity Temperature Pressure
Sensor Inductive cell Platinum thermometer Precision-machined Silicon
Range 0 to 70 mS cm-1 -2 to 35°C Customer specified
Accuracy ±0.002 mS cm-1 0.002°C ±0.01 % full scale
Resolution 0.0001 mS cm-1 0.00005°C 0.0004 % full scale
Response 5.0 cm at 1 ms-1

150 ms Platinum

20 ms Thermistor*

25 ms

*Optional

Further details can be found in the manufacturer's specification sheet.

Cirolana 10/95 CTD Data Documentation

Documentation for CTD data collected by R.V. Cirolana, 10/95 (24 November - 22 December) of the Centre for Environment Fisheries and Aquaculture Science. More information will be included when BODC receive it.


Project Information


No Project Information held for the Series

Data Activity or Cruise Information

Cruise

Cruise Name CIR10/95
Departure Date 1995-11-24
Arrival Date 1995-12-22
Principal Scientist(s)Kinson S Leonard (Ministry of Agriculture, Fisheries and Food Lowestoft Fisheries Laboratory)
Ship RV Cirolana

Complete Cruise Metadata Report is available here


Fixed Station Information


No Fixed Station Information held for the Series


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification