Search the data

Metadata Report for BODC Series Reference Number 552684


Metadata Summary

Data Description

Data Category CTD or STD cast
Instrument Type
NameCategories
Falmouth Scientific Instruments NXIC CTD Series  CTD; water temperature sensor; salinity sensor
Instrument Mounting research vessel
Originating Country United Kingdom
Originator -
Originating Organization Ministry of Agriculture, Fisheries and Food Lowestoft Fisheries Laboratory (now Centre for Environment, Fisheries and Aquaculture Science Lowestoft Laboratory)
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) Joint Nutrient Study I (JoNuS)
 

Data Identifiers

Originator's Identifier CO13/93/156
BODC Series Reference 552684
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 1993-12-21 01:42
End Time (yyyy-mm-dd hh:mm) -
Nominal Cycle Interval -
 

Spatial Co-ordinates

Latitude 52.99970 N ( 52° 60.0' N )
Longitude 3.13330 E ( 3° 8.0' E )
Positional Uncertainty Unspecified
Minimum Sensor or Sampling Depth 0.0 m
Maximum Sensor or Sampling Depth 28.7 m
Minimum Sensor or Sampling Height 4.3 m
Maximum Sensor or Sampling Height 33.0 m
Sea Floor Depth 33.0 m
Sea Floor Depth Source -
Sensor or Sampling Distribution Variable common depth - All sensors are grouped effectively at the same depth, but this depth varies significantly during the series
Sensor or Sampling Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
Sea Floor Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
 

Parameters

BODC CODERankUnitsTitle
PRESPR011DecibarsPressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level
PSALPR011DimensionlessPractical salinity of the water body by conductivity cell and computation using UNESCO 1983 algorithm
TEMPST011Degrees CelsiusTemperature of the water body by CTD or STD

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database


Data Access Policy

Public domain data

These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.

The recommended acknowledgment is

"This study uses data from the data source/organisation/programme, provided by the British Oceanographic Data Centre and funded by the funding body."


Narrative Documents

Falmouth Scientific NXIC CTD Series

The FSI NXIC CTD Series is a collection of rugged Conductivity-Temperature-Depth profilers that utilise the patented Non-eXternal Inductive Cell (NXIC) conductivity sensor, which was originally developed for the US Navy DT-705 Sound Velocity/Salinity sensor. The CTDs are fast sampling, fully integrated instruments with optional battery power, datalogging and external analog sensor input.

Models in the collection include the NXIC CT Bio Direct Read-500M, NXIC CTD Bio Direct Read-500M, NXIC CTD Bio Auto-500M, NXIC CTD Direct Read-500M, NXIC CTD Direct Read-700M, NXIC CTD Auto-500M, NXIC CTD Auto-700M, NXIC CTD-ADC with external sensors, and the NXIC ETSG Thermosalinograph. Parameters are measured to an accuracy ranging from 0.002-0.010 mS/cm for conductivity, 0.005 degC for temperature and 0.08% for full scale pressure. Now marketed by Teledyne RD Instruments.

Specifications

  Conductivity Temperature Pressure
Sensor type Inductive cell Thermistor Precision-machined Silicon
Range 0 to 9.0 S m-1 -5 to 45°C user specified
Accuracy ± 0.0002 S m-1 ± 0.005°C 0.08 % full scale
Stability ± 0.00005 S cm-1 month-1 0.0005°C month-1 ± 0.004 %
Resolution 0.00001 S m-1 0.001°C 0.001 % full scale
Response 5.0 cm at 1 m sec-1 flow 100 msec 25 msec

Further details can be found in the manufacturer's specification sheet and Series Brochure.

RV Corystes 13/1993 (JONUS Exercise 21) CTD Data Documentation

Introduction

This cruise used the FSI CTD s/n 1322 at the JONUS stations. The following is a presentation of the data returned from stations 45-160.

Data Collection

40 CTD profiles were obtained using the FSI CTD during the cruise.

Reversing thermometers were used to measure water temperature and samples were collected for salinity analysis.

Left and right thermometer temperatures were available on 37 occasions. 10 pairs of thermometer results had a difference of > 0.04 and, of these, 1 pair was not used. Of the remaining 9, either left or right thermometer only was used.

All thermometers were graduated at 0.02 °C intervals and a comparison of the differences is as follows:

Difference °C No. Accumulative %
0.00 - 0.01 8 22
0.01 - 0.02 9 46
0.02 - 0.03 4 57
0.03 - 0.04 6 73
>0.04 10   100

Thus, 46% of the differences lie within the range ±0.02 °C, the thermometer scale graduation.

Sample Salinity Data

Duplicate water samples were collected on 4 occasions for analysis with a salinometer.

All the differences were less than or equal to 0.003.

Sensor Calibration for FSI CTD

Pressure

The following calibration of 11/11/1993, was used to correct the FSI CTD pressure sensor:

P(cor) = P(ctd) + 0.1

Temperature

Fig. 1 shows the differences between the (mean) thermometer and uncorrected CTD temperature (36 occasions).

The mean difference calculated was 0.004.

This compares with the laboratory pre-cruise calibration which estimated the CTD correction to be approximately -0.004 °C at the temperatures encountered during the cruise. The sensor was corrected using the laboratory pre-cruise calibration coefficients:

T(cor) = T(ctd) - 0.004

Fig. 2 shows the differences between these 36 thermometer and CTD temperatures after the latter have been corrected. The mean difference is 0.008 °C and 81% of the differences lie within ±0.03 °C, supporting the belief that if the thermometers are accurate to ±0.02 °C then the CTD temperatures are accurate to ±0.01 °C.

Salinity

Fig. 3 shows the difference between the water sample salinity as measured with the portable salinometer and that derived from the CTD before any calibrations have been applied to the latter's sensors.

Fig. 4 shows the ratio of CTD:Water sample conductivity ratio after the CTD pressure and temperature sensors have been corrected using the above coefficients, and after the removal of 8 suspicious values.

A set of coefficients have been derived to calibrate the CTD conductivity sensor, using a least square fit between the ratio of water sample and CTD conductivity and the CTD temperature and pressure.

CR(cor) = CR(ctd)*{a*T(cor) + b*P(cor) + c}

where:

T(cor) and P(cor) are the corrected CTD temperature and pressure
and a = -3.02508292e-05
b = 1.15875306e-06
c = 1.0001132

RMS salinity difference between water sample and corrected CTD = 0.01 (number of data values = 65)

Figs. 5a and 5b illustrate how effective the CTD conductivity and derived salinity have been corrected.

The histograms in Fig. 6 show a small correction in CTD conductivity using the derived coefficients, since the upper frame has been derived after the CTD temperature and pressure have been corrected, but before the CTD conductivity calibration has been applied.

If it is assumed that the salinometer is accurate to 0.006 and the CTD salinity to 0.01, then differences between ± 0.016 are acceptable. 89% of the values lie within this range after the calibrations have been applied.

Transmission/Suspended Load

No transmission was logged in the CTD decimated files, or recorded on the log sheets. Therefore, no calibration was possible.

General Data Screening carried out by BODC

BODC screen both the series header qualifying information and the parameter values in the data cycles themselves.

Header information is inspected for:

  • Irregularities such as unfeasible values
  • Inconsistencies between related information, for example:
    • Times for instrument deployment and for start/end of data series
    • Length of record and the number of data cycles/cycle interval
    • Parameters expected and the parameters actually present in the data cycles
  • Originator's comments on meter/mooring performance and data quality

Documents are written by BODC highlighting irregularities which cannot be resolved.

Data cycles are inspected using time or depth series plots of all parameters. Currents are additionally inspected using vector scatter plots and time series plots of North and East velocity components. These presentations undergo intrinsic and extrinsic screening to detect infeasible values within the data cycles themselves and inconsistencies as seen when comparing characteristics of adjacent data sets displaced with respect to depth, position or time. Values suspected of being of non-oceanographic origin may be tagged with the BODC flag denoting suspect value; the data values will not be altered.

The following types of irregularity, each relying on visual detection in the plot, are amongst those which may be flagged as suspect:

  • Spurious data at the start or end of the record.
  • Obvious spikes occurring in periods free from meteorological disturbance.
  • A sequence of constant values in consecutive data cycles.

If a large percentage of the data is affected by irregularities then a Problem Report will be written rather than flagging the individual suspect values. Problem Reports are also used to highlight irregularities seen in the graphical data presentations.

Inconsistencies between the characteristics of the data set and those of its neighbours are sought and, where necessary, documented. This covers inconsistencies such as the following:

  • Maximum and minimum values of parameters (spikes excluded).
  • The occurrence of meteorological events.

This intrinsic and extrinsic screening of the parameter values seeks to confirm the qualifying information and the source laboratory's comments on the series. In screening and collating information, every care is taken to ensure that errors of BODC making are not introduced.


Project Information

Joint Nutrient Study I (JoNuS)

Concerns by the scientific community about the impact of nutrient inputs to the sea; a lack of information on inputs from the UK and on the spatial and temporal distribution and cycling of nutrients in UK waters provided the impetus for the JoNuS project.

The project sought to quantify the input of nitrogen, phosphorus and silicon from UK estuaries to the North Sea through a good understanding of the estuarine processes that control the flow of these nutrients. It focussed on the Great Ouse/Wash and the Humber outflows. Its specific objectives were:

  • To measure the fluxes of nutrient elements (N, P, Si) through selected major estuaries on a quantitative annual basis in order to determine the net input to the sea resulting from gross river inputs.
  • To quantify the processes controlling the fluxes of nutrients through estuaries.

The Centre for Environment, Fisheries and Aquaculture Science (CEFAS) hosted the project, which involved scientists from CEFAS, the University of East Anglia, the University of Essex, the Plymouth Marine Laboratory and the National Rivers Authority (now the Environment Agency). It was funded by the then Ministry of Agriculture, Fisheries and Food (MAFF) and the Department of Environment, now the Department of Environment, Food and Rural Affairs (Defra).

The project ran from April 1990 to March 1995, with marine field data collection between May 1990 and December 1993. Data collection involved ship based surveys which were complemented by estuarine transects and specific process studies.

Initially, the surveys were on a quarterly basis up to October 1992, however monthly surveys were carried out during 1993. During this intensive survey period, the programme focused on the Great Ouse/Wash; with a continuing, but lower level, of activity devoted to the Humber. An additional multi-project cruise, carried out in January 1995, also complemented the JoNuS data set. Further details of the JoNuS I cruises are provided below:

Cruise identifier Date Comments
RV Cirolana CIR5/90 1990-05-03 - 1990-05-20 None
RV Cirolana CIR7/90 1990-07-06 - 1990-07-25 None
RV Cirolana CIR10/90 1990-10-29 - 1990-11-16 None
Seeker 2/90 1990-10-29 - 1990-11-03 Sediment and water sample collection only
RV Cirolana CIR1/91 1991-01-05 - 1991-01-23 None
RV Cirolana CIR4/91 1991-04-12 - 1991-05-02 None
RV Cirolana CIR8A/91 1991-09-25 - 1991-10-09 None
RV Corystes (88-04) COR1/92 1992-01-03 - 1992-01-20 None
RV Corystes (88-04) COR3A/92 1992-02-14 - 1992-02-26 None
RV Cirolana CIR8/92 1992-07-29 - 1992-08-06 None
RV Corystes (88-04) COR11/92 1992-09-28 - 1992-10-12 None
RV Cirolana CIR1/93 1993-01-08 - 1993-01-22 None
RV Corystes (88-04) COR2A/93 1993-02-03 - 1993-02-07 None
RV Corystes (88-04) COR2C/93 1993-02-18 - 1993-02-24 None
RV Corystes (88-04) COR5A/93 1993-05-04 - 1993-05-10 None
RV Corystes (88-04) COR6A/93 1993-06-08 - 1993-06-14 None
RV Cirolana CIR7B/93 1993-07-26 - 1993-08-02 None
RV Corystes (88-04) COR9/93 1993-08-20 - 1993-08-26 None
RV Cirolana CIR9B/93 1993-09-30 - 1993-10-11 None
RV Corystes (88-04) COR13/93 1993-12-15 - 1993-12-21 None
RV Cirolana CIR1/95 1995-01-06 - 1995-01-31 None

Data Activity or Cruise Information

Cruise

Cruise Name COR13/93
Departure Date 1993-12-15
Arrival Date 1993-12-21
Principal Scientist(s)Stephen James Malcolm (Ministry of Agriculture, Fisheries and Food Lowestoft Fisheries Laboratory)
Ship RV Corystes

Complete Cruise Metadata Report is available here


Fixed Station Information


No Fixed Station Information held for the Series


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification