Metadata Report for BODC Series Reference Number 756190
Metadata Summary
Problem Reports
Data Access Policy
Narrative Documents
Project Information
Data Activity or Cruise Information
Fixed Station Information
BODC Quality Flags
SeaDataNet Quality Flags
Metadata Summary
Data Description |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Data Identifiers |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Time Co-ordinates(UT) |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Spatial Co-ordinates | |||||||||||||||||||||||||
|
|||||||||||||||||||||||||
Parameters |
|||||||||||||||||||||||||
|
|||||||||||||||||||||||||
|
Problem Reports
No Problem Report Found in the Database
Data Access Policy
Open Data
These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.
If the Information Provider does not provide a specific attribution statement, or if you are using Information from several Information Providers and multiple attributions are not practical in your product or application, you may consider using the following:
"Contains public sector information licensed under the Open Government Licence v1.0."
Narrative Documents
Instrument description
Lockheed Martin Sippican T-5 XBT Probe
The Expendable Bathythermograph system uses a sea water ground. As soon as an electrode within the nose of the expendable probe makes contact with the water, the circuit is complete and temperature or sound velocity data can be telemetered to the ship-board data processing equipment. The T-5 XBT Probe can be used within a maximum depth of 1830 m, with a rated ship speed of 6 knots and has a vertical resolution of 65 cm.
Manufacturer specifications can be found here
BODC Processing
The data arrived at BODC in 25 ASCII format files representing the casts taken during JR20080415. Files were reformatted to BODC's internal format (subset of NETCDF) and mapped to appropriate BODC parameter codes:
Originator's Variable | Units | Description | BODC Parameter Code | Units | Comments |
Depth | m | Depth of instrument | DEPHCV01 | m | - |
Sound Velocity | ms -1 | Velocity of sound through water column | SVELVP01 | ms -1 | - |
Temperature | °C | Temperature of water | TEMPET01 | °C | - |
The reformatted data were visualised using the in-house EDSERPLO software. Suspect data were marked by adding an appropriate quality control flag. Missing data values were changed to the missing data value and assigned a BODC data quality flag.
Instrument Description
XBT Unit and Auxiliary Sensors
Probe type | T-5 |
Terminal depth | 1830 m |
Depth equation | Standard |
Depth Coeff. 1 | 0.0 |
Depth Coeff. 2 | 6.828 |
Depth Coeff. 3 | -0.00182 |
Depth Coeff. 4 | 0.0 |
Pressure Pt. Correction | 100.0% |
Project Information
BAS Long Term Monitoring and Survey
Introduction
The Long Term Monitoring and Survey project (LTMS) has been running since the British Antarctic Survey (BAS) was created. This project is one of the BAS core projects, with several groups of scientists collecting various types of data e.g biological, geological, atmospheric, among others.
Data collection is achievable through a wide scope of instruments and platforms, e.g. the Antarctic research stations, autonomous instrument platforms deployed on or from BAS research ships, BAS aircrafts, satellite remote sensing and others.
Scientific Objectives
This project was implemented in order to measure change and variability in the Earth system. Its long term duration allows for the monitoring of processes that could be missed in shorter term studies and experiments. The data collected is also used to check and improve the reliability of models used to stimulate and predict the behavior of the Earth system.
The main objectives are:
- Topographic survey
- Geosciences survey
- Biological survey and monitoring
- Atmospheric and oceanographic monitoring
Data Availability
The data sets obtained through this project are available to the academic community.
Data Activity or Cruise Information
Cruise
Cruise Name | JR20080415 (JR186, JR214, JR222, JR223) |
Departure Date | 2008-04-15 |
Arrival Date | 2008-05-06 |
Principal Scientist(s) | Paul Provost (National Marine Facilities Sea Systems), Sophie Fielding (British Antarctic Survey) |
Ship | RRS James Clark Ross |
Complete Cruise Metadata Report is available here
Fixed Station Information
No Fixed Station Information held for the Series
BODC Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
Blank | Unqualified |
< | Below detection limit |
> | In excess of quoted value |
A | Taxonomic flag for affinis (aff.) |
B | Beginning of CTD Down/Up Cast |
C | Taxonomic flag for confer (cf.) |
D | Thermometric depth |
E | End of CTD Down/Up Cast |
G | Non-taxonomic biological characteristic uncertainty |
H | Extrapolated value |
I | Taxonomic flag for single species (sp.) |
K | Improbable value - unknown quality control source |
L | Improbable value - originator's quality control |
M | Improbable value - BODC quality control |
N | Null value |
O | Improbable value - user quality control |
P | Trace/calm |
Q | Indeterminate |
R | Replacement value |
S | Estimated value |
T | Interpolated value |
U | Uncalibrated |
W | Control value |
X | Excessive difference |
SeaDataNet Quality Control Flags
The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:
Flag | Description |
---|---|
0 | no quality control |
1 | good value |
2 | probably good value |
3 | probably bad value |
4 | bad value |
5 | changed value |
6 | value below detection |
7 | value in excess |
8 | interpolated value |
9 | missing value |
A | value phenomenon uncertain |
B | nominal value |
Q | value below limit of quantification |