Search the data

Metadata Report for BODC Series Reference Number 748927


Metadata Summary

Data Description

Data Category Currents -subsurface Eulerian
Instrument Type
NameCategories
Teledyne RDI Workhorse Sentinel-300 ADCP  current profilers
Instrument Mounting subsurface mooring
Originating Country France
Originator Dr Valerie Quiniou-Ramus
Originating Organization Total (now Total S.A.)
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) SIMORC
EEA Girassol Current Measurement Survey
 

Data Identifiers

Originator's Identifier ANGW2CURR
BODC Series Reference 748927
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 1997-12-10 12:20
End Time (yyyy-mm-dd hh:mm) 1998-02-25 08:00
Nominal Cycle Interval 1200.0 seconds
 

Spatial Co-ordinates

Latitude 7.67000 S ( 7° 40.2' S )
Longitude 11.68250 E ( 11° 40.9' E )
Positional Uncertainty 0.05 to 0.1 n.miles
Minimum Sensor or Sampling Depth 3.0 m
Maximum Sensor or Sampling Depth 45.0 m
Minimum Sensor or Sampling Height 1340.0 m
Maximum Sensor or Sampling Height 1382.0 m
Sea Floor Depth 1385.0 m
Sea Floor Depth Source -
Sensor or Sampling Distribution Sensor fixed with measurements made at multiple depths within a fixed range (e.g. ADCP) - The sensor is at a fixed depth, but measurements are made remotely from the sensor over a range of depths (e.g. ADCP measurements)
Sensor or Sampling Depth Datum Mean sea level - Depth expressed relative to mean sea level as defined by the data originator
Sea Floor Depth Datum Chart reference - Depth extracted from available chart
 

Parameters

BODC CODERankUnitsTitle
HBINAA010MetresHeight (spatial coordinate) of ADCP bin relative to bed surface in the water body
AADYAA011DaysDate (time from 00:00 01/01/1760 to 00:00 UT on day)
AAFDZZ011DaysTime (time between 00:00 UT and timestamp)
ACYCAA011DimensionlessSequence number
TEMPPR011Degrees CelsiusTemperature of the water body
LCDAAP012Degrees TrueDirection (towards) of water current (Eulerian measurement) in the water body by moored acoustic doppler current profiler (ADCP) and correction to true North
LCSAAP012Centimetres per secondSpeed of water current (Eulerian measurement) in the water body by moored acoustic doppler current profiler (ADCP)

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database

SIMORC Data Quality Report: Angola Girassol ADCP Current ANGW2CURR

No speed and direction data for bins 9 and 10. There is a large amount of absent values for current data. Direction data are noisier near the surface. Temperature data appear of good quality.


Data Access Policy

SIMORC data access conditions

The data collated and held at BODC on behalf of the SIMORC project are restricted. However, the data will be available to download from the Official SIMORC Website, as part of the project protocol. The data set will initially include data from the oil companies TOTAL, Shell and BP.


Narrative Documents

RD Instruments 300kHz Workhorse Sentinel Acoustic Doppler Current Profiler

Specifications

Water velocity measurements relative to the ADCP
Maximum velocity 10 m.s-1
Standard deviation 130, 45, 25, 12, 5 mm.s-1 for depth cell sizes of 1, 2, 4, 8, 16 m, respectively
Minimum time between pings 0.07 s
Maximum profiling range* 110, 120, 130, 150, 165 m for depth cell sizes of 1, 2, 4, 8, 16 m, respectively
Minimum range to start of first depth cell 3 m
Number of depth cells 1 - 128 cells
Depth cell size 1 - 16 cm
Echo Intensity measurements
Uncertainty ± 1.5 dB
Sampling Uses same depth cells and time intervals as velocity
Sensors
Water level resolution 0.25 m
Water level accuracy ± 5 m over 0-200 m depth
Temperature range -5°C to + 45°C
Temperature uncertainty ± 0.4°C
Tilt range ± 20°
Tilt uncertainty ± 2°
Compass uncertainty ± 5° at 60° magnetic dip angle
Compass maximum tilt 20°
Physical and Environmental
Maximum depth 200 m
Operating temperature -5°C to 60°C
Storage Temperature -5°C to 80°C

The manufacturer's specification document can be found here

RDI Acoustic Doppler Current Profiler

Acoustic Doppler Current Profilers (ADCPs) use sound waves to determine vertical profiles of currents, and may be deployed fixed to the sea floor, attached to a surface buoy, mounted on the hull of a ship, towed behind a ship or lowered on a cable.

ADCPs transmit sound bursts into the water. Particles carried by the water currents scatter the sound back to the transducer. As echoes return from further ranges from the sensor, the instrument assigns different water depths to the returning signals. Motion of the scattering particles relative to the sound source causes a change in the frequency of the sound (known as Doppler shift). The ADCP measures this change to produce vertical profiles of water velocity at up to 128 depths throughout the water column.

Specifications:
number of depth cells 1 to 128;
size of depth cells 0.12 to 32.00 metres;
velocity range +/- 10 m/s.

BODC Processing

Data were received by BODC in ASCII format files. These were reformatted to the internal QXF format using BODC transfer function 370. The following table shows how the variables within the file were mapped to the appropriate BODC parameter codes:

Original parameter name Original Units Description BODC Parameter Code BODC Units Comments
Time YYYY.MM.DD.hh:mm Date and time AADYAA01 + AAFDZZ01 Day number and day fraction Conversion by transfer
SEA_TEMPERATURE degrees Celsius Temperature measured at depth of the instrument TEMPPR01 degrees Celsius  
MEAN_TOTAL_CURRENT_SPEED m.s-1 Scalar speed associated with 20-minute vector-average velocity in a defined 4m or 8m layer of water column LCSAAP01 cm.s-1 Conversion (RAW *100) by transfer
MEAN_TOTAL_CURRENT_DIRECTION degrees true Direction (to) associated with 20-minute vector-average velocity in a defined 4m or 8m layer of water column LCDAAP01 degrees true  

Following transfer to QXF, the data were screened using BODC's in-house visualisation software, EDSERPLO. The following problems were noted with the data:

Series: 748939 The screening of LCDAAP01 shows the following spikes which were accordingly flagged:

  • bin 2 cycles 2191, 2452, 2743, 3263, 3273
  • bin 3 cycles 2743, 3169, 3270
  • bin 5 cycle 2757
  • bin 6 cycles 2738, 3270
  • bin 7 cycle 3273
  • bin 8 cycle 3270
  • bin 11 cycles 2757, 3273

Series: 743940 The screening of TEMPPR01 shows a suspicious variation of the temperature for cycle 1 and 2, which were accordingly flagged.

Originator's data Processing notes

SIMORC Total Angola Bloc17, Current data, 1997, Data processing

Initial validation checks were applied to the data to flag erroneous values for editing prior to further analysis. Consideration was given to:

  • Timing of data points.
  • Data points outside the physical limits of the sensors or the environment.
  • Rates of change between data points.

Checks were made for timing errors by comparing the data with the recorded switch-on and switch-off times manually on the log sheets. Directional data were corrected for magnetic declination to give results expressed in Degrees True. The local magnetic declination is 7.2 ° W.

Time series of all data were plotted, and reviewed by an experienced oceanographer, to allow identification and removal of erroneous records. A number of anomalous increases in current speed (i.e. spikes) were identified and manually removed.

Additionally, routine ADCP quality control was performed on the ADCP data. Workhorse ADCP data for the upper 7m of the water column were error-flagged due to contamination from acoustic side lobe reflection from the surface. Records with less than 25% good pings were also flagged.

General Data Screening carried out by BODC

BODC screen both the series header qualifying information and the parameter values in the data cycles themselves.

Header information is inspected for:

  • Irregularities such as unfeasible values
  • Inconsistencies between related information, for example:
    • Times for instrument deployment and for start/end of data series
    • Length of record and the number of data cycles/cycle interval
    • Parameters expected and the parameters actually present in the data cycles
  • Originator's comments on meter/mooring performance and data quality

Documents are written by BODC highlighting irregularities which cannot be resolved.

Data cycles are inspected using time or depth series plots of all parameters. Currents are additionally inspected using vector scatter plots and time series plots of North and East velocity components. These presentations undergo intrinsic and extrinsic screening to detect infeasible values within the data cycles themselves and inconsistencies as seen when comparing characteristics of adjacent data sets displaced with respect to depth, position or time. Values suspected of being of non-oceanographic origin may be tagged with the BODC flag denoting suspect value; the data values will not be altered.

The following types of irregularity, each relying on visual detection in the plot, are amongst those which may be flagged as suspect:

  • Spurious data at the start or end of the record.
  • Obvious spikes occurring in periods free from meteorological disturbance.
  • A sequence of constant values in consecutive data cycles.

If a large percentage of the data is affected by irregularities then a Problem Report will be written rather than flagging the individual suspect values. Problem Reports are also used to highlight irregularities seen in the graphical data presentations.

Inconsistencies between the characteristics of the data set and those of its neighbours are sought and, where necessary, documented. This covers inconsistencies such as the following:

  • Maximum and minimum values of parameters (spikes excluded).
  • The occurrence of meteorological events.

This intrinsic and extrinsic screening of the parameter values seeks to confirm the qualifying information and the source laboratory's comments on the series. In screening and collating information, every care is taken to ensure that errors of BODC making are not introduced.


Project Information

System of Industry Metocean data for the Offshore and Research Communities (SIMORC)

The EU-funded SIMORC project is a collaborative effort between MARIS (Netherlands), BODC (UK), the International Association of Oil and Gas Producers (OGP) and IOC-IODE to provide a harmonised and quality controlled metocean data set from data collected by oil and gas producers, accessible through the SIMORC protocol.


ELF EXPLORATION ANGOLA, Girassol, Deep Water Current Measurements

Period: September 1997 - October 1998.

The goal of this was to observe and characterize the nature of the current regime in this area. This study is a preliminary to the riser design for the Girassol field production well (2 km east from the mooring position).

This deployment was divided into five phases, to allow approximately 75 day intervals between visits for data retrieval and equipment maintenance.


Data Activity or Cruise Information

Data Activity

Start Date (yyyy-mm-dd) 1997-12-10
End Date (yyyy-mm-dd) 1998-02-25
Organization Undertaking ActivityTotal (now Total S.A.)
Country of OrganizationFrance
Originator's Data Activity IdentifierSIMORC TTL Angola Block 17 Curr Dec 97
Platform Categorysubsurface mooring

SIMORC: TOTAL Data, Angola, Block 17, ADCP Current 10/12/1997 - 25/02/1998 Data Activity

This site is part of the Total facility.

The generic position of the site is 7.67 °S, 11.6825 °E with a water depth of 1385 m.

The objective of the year-long study was to observe and characterise the nature of the current regime in this area. The data were used to help in riser design of a Girassol field production well, located approximately 2 km east of the mooring position.

5 current moorings, consisting of 2 ADCP and 6 current meters, were deployed during this study.

This particular mooring had been set from a vessel by FugroGeos on behalf of Total in the Angola Block 17 Girassol and consisted of the following instruments.

Instrument type Depth(m) Instrument Serial Number Deployment Start Deployment End
RD Instruments 300 KHz, 10 bins of 4 m depth 45 0393 10/12/1997 12:20 25/02/1998 08:00
RD Instruments 150 KHz, 22 bins of 8 m depth 205 02308 10/12/1997 12:20 25/02/1998 08:00
Aanderaa RCM7 385 11398 10/12/1997 12:20 25/02/1998 08:00
Aanderaa RCM7 585 12418 10/12/1997 12:20 25/02/1998 08:00
Aanderaa RCM7 785 11400 10/12/1997 12:20 25/02/1998 08:00
Aanderaa RCM7 985 12417 10/12/1997 12:20 25/02/1998 08:00
Aanderaa RCM7 1185 11260 10/12/1997 12:20 25/02/1998 08:00
Aanderaa RCM7 1370 11492 10/12/1997 12:20 25/02/1998 08:00

For details of the 4 other moorings refer to series: 747844, 747997, 748048, 748116.

CTD profiles were recorded after the deployment and prior to the recovery to calibrate against the mooring.

Related Data Activity activities are detailed in Appendix 1


Fixed Station Information

Fixed Station Information

Station NameANGOLA GIRASSOL
CategoryOffshore location
Latitude7° 41.10' S
Longitude11° 39.98' E
Water depth below MSL1385.0 m

SIMORC: Total Angola, Block 17 Girassol, Fixed Station Document

This site is part of the Total facility.

The moorings deployed lie within a box bounded by co-ordinates 7.7° S, 11.65° E at the southwest corner and 7.67° S, 11.6825° E at the northeast corner.

The GIRASSOL platform, Block 17, offshore Angola consists of a Floating Production, Storage and Offloading vessel (FPSO) and a Single Buoy Mooring (SBM).

Various deployments were taken from or near this station over a number of years.

Between September 1997 and October 1998

A current meter mooring occupied this site. In addition to time series data obtained from the moored instruments, CTD profiles were conducted following the deployment and prior to the recovery of the mooring to be used for calibration purposes.

Between March 2001 and July 2004

Wind, current and wave data have been collected on behalf of Total on the Girassol field.

Related Fixed Station activities are detailed in Appendix 2


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification

Appendix 1: SIMORC TTL Angola Block 17 Curr Dec 97

Related series for this Data Activity are presented in the table below. Further information can be found by following the appropriate links.

If you are interested in these series, please be aware we offer a multiple file download service. Should your credentials be insufficient for automatic download, the service also offers a referral to our Enquiries Officer who may be able to negotiate access.

Series IdentifierData CategoryStart date/timeStart positionCruise
747912Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747924Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747936Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747948Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747961Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747973Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
748915Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable

Appendix 2: ANGOLA GIRASSOL

Related series for this Fixed Station are presented in the table below. Further information can be found by following the appropriate links.

If you are interested in these series, please be aware we offer a multiple file download service. Should your credentials be insufficient for automatic download, the service also offers a referral to our Enquiries Officer who may be able to negotiate access.

Series IdentifierData CategoryStart date/timeStart positionCruise
746042CTD or STD cast1997-09-22 13:00:007.67 S, 11.6825 EOil Tempest 1/97
747844Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
747856Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
747868Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
747881Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
747893Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
747900Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
748896Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
748903Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
746017CTD or STD cast1997-12-10 12:20:007.67 S, 11.6825 EOil Tempest 2/97
747912Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747924Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747936Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747948Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747961Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747973Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
748915Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747985Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
747997Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
748000Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
748012Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
748024Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
748036Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
748939Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
748940Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
746005CTD or STD cast1998-05-08 08:00:007.67 S, 11.6825 EOil Tempest 3/98
746029CTD or STD cast1998-05-10 09:00:007.67 S, 11.6825 EOil Tempest 3/98
748048Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
748061Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
748073Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
748085Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
748097Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
748104Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
748952Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
748964Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
746030CTD or STD cast1998-07-22 08:40:007.67 S, 11.6825 EMV Schaartor 4/98
746054CTD or STD cast1998-07-23 10:20:007.67 S, 11.6825 EMV Schaartor 4/98
748116Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
748128Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
748141Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
748153Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
748165Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
748177Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
748976Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
748988Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
746066CTD or STD cast1998-10-27 09:40:007.67 S, 11.6825 EMV Schaartor 5/98
1095363CTD or STD cast2000-07-22 00:00:007.58722 S, 11.67015 ENot applicable
750944Waves (statistics)2001-03-08 15:00:007.6985 S, 11.6715 ENot applicable
896212Meteorology -unspecified2001-09-01 00:00:007.7 S, 11.66667 ENot applicable
749758Currents -subsurface Eulerian2002-05-22 19:30:007.6985 S, 11.65383 ENot applicable
749771Currents -subsurface Eulerian2002-05-22 19:30:007.6985 S, 11.65383 ENot applicable
746644Winds -unspecified2002-05-23 16:27:337.7 S, 11.667 ENot applicable
746656Winds -unspecified2002-06-01 00:56:277.7 S, 11.667 ENot applicable
746668Winds -unspecified2002-07-01 00:08:277.7 S, 11.667 ENot applicable
746681Winds -unspecified2002-08-01 00:26:447.7 S, 11.667 ENot applicable
749783Currents -subsurface Eulerian2002-08-22 15:00:007.69667 S, 11.6545 ENot applicable
749795Currents -subsurface Eulerian2002-08-22 15:00:007.69667 S, 11.6545 ENot applicable
746693Winds -unspecified2002-09-01 00:34:017.7 S, 11.667 ENot applicable
746700Winds -unspecified2002-10-01 00:22:467.7 S, 11.667 ENot applicable
1095314CTD or STD cast2002-10-27 11:03:007.69506 S, 11.70541 ENot applicable
1095326CTD or STD cast2002-10-28 23:19:007.67059 S, 11.71846 ENot applicable
746712Winds -unspecified2002-11-01 00:02:027.7 S, 11.667 ENot applicable
749802Currents -subsurface Eulerian2002-11-11 18:00:007.6985 S, 11.65383 ENot applicable
749814Currents -subsurface Eulerian2002-11-11 18:00:007.6985 S, 11.65383 ENot applicable
746724Winds -unspecified2002-12-01 00:10:057.7 S, 11.667 ENot applicable
746736Winds -unspecified2003-01-01 00:27:277.7 S, 11.667 ENot applicable
746748Winds -unspecified2003-02-01 00:12:597.7 S, 11.667 ENot applicable
749826Currents -subsurface Eulerian2003-02-14 20:00:007.7 S, 11.65 ENot applicable
749838Currents -subsurface Eulerian2003-02-14 20:00:007.7 S, 11.65 ENot applicable
746761Winds -unspecified2003-03-01 00:44:297.7 S, 11.667 ENot applicable
746773Winds -unspecified2003-04-02 01:01:117.7 S, 11.667 ENot applicable
746785Winds -unspecified2003-05-01 00:48:507.7 S, 11.667 ENot applicable
749851Currents -subsurface Eulerian2003-05-25 20:00:007.7 S, 11.65 ENot applicable
746797Winds -unspecified2003-06-01 00:06:357.7 S, 11.667 ENot applicable
746804Winds -unspecified2003-07-01 00:59:357.7 S, 11.667 ENot applicable
746816Winds -unspecified2003-08-01 00:27:037.7 S, 11.667 ENot applicable
746828Winds -unspecified2003-09-01 00:55:137.7 S, 11.667 ENot applicable
746841Winds -unspecified2003-11-09 08:03:047.7 S, 11.667 ENot applicable
746853Winds -unspecified2003-12-01 00:11:477.7 S, 11.667 ENot applicable
746865Winds -unspecified2004-01-01 00:15:207.7 S, 11.667 ENot applicable
749863Currents -subsurface Eulerian2004-01-11 16:00:007.7 S, 11.65 ENot applicable
746877Winds -unspecified2004-02-01 00:13:267.7 S, 11.667 ENot applicable
746889Winds -unspecified2004-03-01 00:21:007.7 S, 11.667 ENot applicable
746890Winds -unspecified2004-04-01 00:01:357.7 S, 11.667 ENot applicable
746908Winds -unspecified2004-05-01 00:56:437.7 S, 11.667 ENot applicable
746921Winds -unspecified2004-06-01 00:09:487.7 S, 11.667 ENot applicable
746933Winds -unspecified2004-07-01 00:21:527.7 S, 11.667 ENot applicable
1095338CTD or STD cast2009-08-02 08:38:007.66825 S, 11.71846 ENot applicable
1095351CTD or STD cast2009-08-02 10:07:007.62991 S, 11.6955 ENot applicable