Search the data

Metadata Report for BODC Series Reference Number 896212


Metadata Summary

Data Description

Data Category Meteorology -unspecified
Instrument Type Meteorological data logger
Instrument Mounting vessel at fixed position
Originating Country France
Originator Dr Valerie Quiniou-Ramus
Originating Organization TotalFinaElf (now Total S.A.)
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) SIMORC
 

Data Identifiers

Originator's Identifier GMET
BODC Series Reference 896212
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 2001-09-01 00:00
End Time (yyyy-mm-dd hh:mm) 2003-06-05 14:52
Nominal Cycle Interval 120.0 seconds
 

Spatial Co-ordinates

Latitude 7.70000 S ( 7° 42.0' S )
Longitude 11.66667 E ( 11° 40.0' E )
Positional Uncertainty 0.01 to 0.05 n.miles
Minimum Sensor or Sampling Depth -60.0 m
Maximum Sensor or Sampling Depth -60.0 m
Minimum Sensor or Sampling Height 1420.0 m
Maximum Sensor or Sampling Height 1420.0 m
Sea Floor Depth 1360.0 m
Sea Floor Depth Source -
Sensor or Sampling Distribution Fixed common depth - All sensors are grouped effectively at the same depth which is effectively fixed for the duration of the series
Sensor or Sampling Depth Datum Mean sea level - Depth expressed relative to mean sea level as defined by the data originator
Sea Floor Depth Datum Unspecified -
 

Parameters

BODC CODERankUnitsTitle
AADYAA011DaysDate (time from 00:00 01/01/1760 to 00:00 UT on day)
AAFDZZ011DaysTime (time between 00:00 UT and timestamp)
ACYCAA011DimensionlessSequence number
CAPHTU011MillibarsPressure (measured variable) exerted by the atmosphere by barometer and expressed at measurement altitude
CRELSS011PercentRelative humidity of the atmosphere by humidity sensor
CTMPZZ011Degrees CelsiusTemperature of the atmosphere

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database

Data quality report of GMET

There are several short gaps:

  • on the 01/09/2001 09:30 to 14:00
  • on the 07/09/2001 from 11:30 to 12:40
  • on the 09/09/2001 from 10:00 to 11:00
  • from 09/09/2001 17:00 to 10/09/2001 07:00
  • on the 10/09/2001 from 09:30 to 10:30
  • on the 30/11/2001 from 09:00 to 18:00
  • on the 11/12/2001 from 12:30 to 13:30
  • on the 09/05/2002 from 11:00 to 15:00
  • on 24/06/2002 10:00 to 14:00

On 18/04/2002 there was a sudden decrease in value of every parameter. This seemed suspicious and was flagged accordingly. The problem resolved itself shortly afterwards.


Data Access Policy

SIMORC data access conditions

The data collated and held at BODC on behalf of the SIMORC project are restricted. However, the data will be available to download from the Official SIMORC Website, as part of the project protocol. The data set will initially include data from the oil companies TOTAL, Shell and BP.


Narrative Documents

Instrument description

QMH101/HMP45A/HMP45D Relative Humidity and Temperature Probes

The Vaisala Relative Humidity and Temperature Probe QMH101/QMH102 is based on Vaisala's HMP45D probes.

Relative humidity measurement

  • Measurement range : from 0.8 to 100 % RH
  • Accuracy at +20 °C (+68 °F) field calibration against references: ±2 % RH (when RH between 0 and 90 % RH) ; ±3 % RH (when RH between 90 and 100 % RH)

Temperature measurement

  • Measurement range: from -40 to +60 °C (from -40 to +140 °F)

Mechanics

  • Cable length: 3.5 m
  • Weight: 350 g (including package)

For more specification, please report to the manufacturer specification here

BODC Processing

Data were received by BODC in ASCII format files. The originator provided monthly files which were concatenated into a Matlab format files for transfer in order to get 1 series per deployment. The average of the data values having the same date and time was calculated and taken (data values being very close and no information about these datacycles was provided), in order to get one unique data value for each date and time.

This series was reformatted to the internal QXF format using BODC transfer function 415. The following table shows how the variables within the file were mapped to the appropriate BODC parameter codes:

Original parameter name Original Units Description BODC Parameter Code BODC Units Comments
Time DD/MM/YYYY HH:MI date and time * AADYAA01 + AAFDZZ01 day number and day fraction GMT Conversion by transfer
QFE millibars Pressure (measured variable) exerted by the atmosphere by barometer and expressed at measurement altitude CAPHTU01 millibars  
RH percent Relative humidity CRELSS01 percent  
T degrees Celsius Temperature CTMPZZ01 degrees Celsius  

* The originator did not specify whether time is GMT or not.

Following transfer to QXF, the data were screened using BODC's in-house visualisation software, EDSERPLO. Any data considered as suspect were flagged 'M'.

General Data Screening carried out by BODC

BODC screen both the series header qualifying information and the parameter values in the data cycles themselves.

Header information is inspected for:

  • Irregularities such as unfeasible values
  • Inconsistencies between related information, for example:
    • Times for instrument deployment and for start/end of data series
    • Length of record and the number of data cycles/cycle interval
    • Parameters expected and the parameters actually present in the data cycles
  • Originator's comments on meter/mooring performance and data quality

Documents are written by BODC highlighting irregularities which cannot be resolved.

Data cycles are inspected using time or depth series plots of all parameters. Currents are additionally inspected using vector scatter plots and time series plots of North and East velocity components. These presentations undergo intrinsic and extrinsic screening to detect infeasible values within the data cycles themselves and inconsistencies as seen when comparing characteristics of adjacent data sets displaced with respect to depth, position or time. Values suspected of being of non-oceanographic origin may be tagged with the BODC flag denoting suspect value; the data values will not be altered.

The following types of irregularity, each relying on visual detection in the plot, are amongst those which may be flagged as suspect:

  • Spurious data at the start or end of the record.
  • Obvious spikes occurring in periods free from meteorological disturbance.
  • A sequence of constant values in consecutive data cycles.

If a large percentage of the data is affected by irregularities then a Problem Report will be written rather than flagging the individual suspect values. Problem Reports are also used to highlight irregularities seen in the graphical data presentations.

Inconsistencies between the characteristics of the data set and those of its neighbours are sought and, where necessary, documented. This covers inconsistencies such as the following:

  • Maximum and minimum values of parameters (spikes excluded).
  • The occurrence of meteorological events.

This intrinsic and extrinsic screening of the parameter values seeks to confirm the qualifying information and the source laboratory's comments on the series. In screening and collating information, every care is taken to ensure that errors of BODC making are not introduced.


Project Information

System of Industry Metocean data for the Offshore and Research Communities (SIMORC)

The EU-funded SIMORC project is a collaborative effort between MARIS (Netherlands), BODC (UK), the International Association of Oil and Gas Producers (OGP) and IOC-IODE to provide a harmonised and quality controlled metocean data set from data collected by oil and gas producers, accessible through the SIMORC protocol.


Data Activity or Cruise Information

Data Activity

Start Date (yyyy-mm-dd) 2001-09-01
End Date (yyyy-mm-dd) 2003-06-05
Organization Undertaking ActivityTotalFinaElf (now Total S.A.)
Country of OrganizationFrance
Originator's Data Activity IdentifierGMET#1
Platform Categoryvessel at fixed position

SIMORC Mooring Angola Girassol GMET#1

A meteorological station was installed on a FPSO (Floating Production, Storage and Offloading vessel) between 01/09/2001 and 05/06/2003.

The nominal position of this series is 7.7° S; 11.66667° E with a water depth of 1360 m.

The meteorological station was deployed on behalf of TOTAL at the Angola Girassol site and consisted of the following instruments.

Height above the surface (m) Instrument type Deployment start Deployment end Comments
60
  • Barometer PMT16A SWD
  • Temperature/humidity sensor QMH101 X0950039
01/09/2001 00:00:00 05/06/2003 14:52:00  

Fixed Station Information

Fixed Station Information

Station NameANGOLA GIRASSOL
CategoryOffshore location
Latitude7° 41.10' S
Longitude11° 39.98' E
Water depth below MSL1385.0 m

SIMORC: Total Angola, Block 17 Girassol, Fixed Station Document

This site is part of the Total facility.

The moorings deployed lie within a box bounded by co-ordinates 7.7° S, 11.65° E at the southwest corner and 7.67° S, 11.6825° E at the northeast corner.

The GIRASSOL platform, Block 17, offshore Angola consists of a Floating Production, Storage and Offloading vessel (FPSO) and a Single Buoy Mooring (SBM).

Various deployments were taken from or near this station over a number of years.

Between September 1997 and October 1998

A current meter mooring occupied this site. In addition to time series data obtained from the moored instruments, CTD profiles were conducted following the deployment and prior to the recovery of the mooring to be used for calibration purposes.

Between March 2001 and July 2004

Wind, current and wave data have been collected on behalf of Total on the Girassol field.

Related Fixed Station activities are detailed in Appendix 1


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification

Appendix 1: ANGOLA GIRASSOL

Related series for this Fixed Station are presented in the table below. Further information can be found by following the appropriate links.

If you are interested in these series, please be aware we offer a multiple file download service. Should your credentials be insufficient for automatic download, the service also offers a referral to our Enquiries Officer who may be able to negotiate access.

Series IdentifierData CategoryStart date/timeStart positionCruise
746042CTD or STD cast1997-09-22 13:00:007.67 S, 11.6825 EOil Tempest 1/97
747844Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
747856Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
747868Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
747881Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
747893Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
747900Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
748896Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
748903Currents -subsurface Eulerian1997-09-22 13:00:007.67 S, 11.6825 ENot applicable
746017CTD or STD cast1997-12-10 12:20:007.67 S, 11.6825 EOil Tempest 2/97
747912Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747924Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747936Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747948Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747961Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747973Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
748915Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
748927Currents -subsurface Eulerian1997-12-10 12:20:007.67 S, 11.6825 ENot applicable
747985Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
747997Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
748000Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
748012Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
748024Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
748036Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
748939Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
748940Currents -subsurface Eulerian1998-02-28 17:20:007.67 S, 11.6825 ENot applicable
746005CTD or STD cast1998-05-08 08:00:007.67 S, 11.6825 EOil Tempest 3/98
746029CTD or STD cast1998-05-10 09:00:007.67 S, 11.6825 EOil Tempest 3/98
748048Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
748061Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
748073Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
748085Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
748097Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
748104Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
748952Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
748964Currents -subsurface Eulerian1998-05-10 09:00:007.67 S, 11.6825 ENot applicable
746030CTD or STD cast1998-07-22 08:40:007.67 S, 11.6825 EMV Schaartor 4/98
746054CTD or STD cast1998-07-23 10:20:007.67 S, 11.6825 EMV Schaartor 4/98
748116Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
748128Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
748141Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
748153Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
748165Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
748177Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
748976Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
748988Currents -subsurface Eulerian1998-07-23 10:20:007.67 S, 11.6825 ENot applicable
746066CTD or STD cast1998-10-27 09:40:007.67 S, 11.6825 EMV Schaartor 5/98
1095363CTD or STD cast2000-07-22 00:00:007.58722 S, 11.67015 ENot applicable
750944Waves (statistics)2001-03-08 15:00:007.6985 S, 11.6715 ENot applicable
749758Currents -subsurface Eulerian2002-05-22 19:30:007.6985 S, 11.65383 ENot applicable
749771Currents -subsurface Eulerian2002-05-22 19:30:007.6985 S, 11.65383 ENot applicable
746644Winds -unspecified2002-05-23 16:27:337.7 S, 11.667 ENot applicable
746656Winds -unspecified2002-06-01 00:56:277.7 S, 11.667 ENot applicable
746668Winds -unspecified2002-07-01 00:08:277.7 S, 11.667 ENot applicable
746681Winds -unspecified2002-08-01 00:26:447.7 S, 11.667 ENot applicable
749783Currents -subsurface Eulerian2002-08-22 15:00:007.69667 S, 11.6545 ENot applicable
749795Currents -subsurface Eulerian2002-08-22 15:00:007.69667 S, 11.6545 ENot applicable
746693Winds -unspecified2002-09-01 00:34:017.7 S, 11.667 ENot applicable
746700Winds -unspecified2002-10-01 00:22:467.7 S, 11.667 ENot applicable
1095314CTD or STD cast2002-10-27 11:03:007.69506 S, 11.70541 ENot applicable
1095326CTD or STD cast2002-10-28 23:19:007.67059 S, 11.71846 ENot applicable
746712Winds -unspecified2002-11-01 00:02:027.7 S, 11.667 ENot applicable
749802Currents -subsurface Eulerian2002-11-11 18:00:007.6985 S, 11.65383 ENot applicable
749814Currents -subsurface Eulerian2002-11-11 18:00:007.6985 S, 11.65383 ENot applicable
746724Winds -unspecified2002-12-01 00:10:057.7 S, 11.667 ENot applicable
746736Winds -unspecified2003-01-01 00:27:277.7 S, 11.667 ENot applicable
746748Winds -unspecified2003-02-01 00:12:597.7 S, 11.667 ENot applicable
749826Currents -subsurface Eulerian2003-02-14 20:00:007.7 S, 11.65 ENot applicable
749838Currents -subsurface Eulerian2003-02-14 20:00:007.7 S, 11.65 ENot applicable
746761Winds -unspecified2003-03-01 00:44:297.7 S, 11.667 ENot applicable
746773Winds -unspecified2003-04-02 01:01:117.7 S, 11.667 ENot applicable
746785Winds -unspecified2003-05-01 00:48:507.7 S, 11.667 ENot applicable
749851Currents -subsurface Eulerian2003-05-25 20:00:007.7 S, 11.65 ENot applicable
746797Winds -unspecified2003-06-01 00:06:357.7 S, 11.667 ENot applicable
746804Winds -unspecified2003-07-01 00:59:357.7 S, 11.667 ENot applicable
746816Winds -unspecified2003-08-01 00:27:037.7 S, 11.667 ENot applicable
746828Winds -unspecified2003-09-01 00:55:137.7 S, 11.667 ENot applicable
746841Winds -unspecified2003-11-09 08:03:047.7 S, 11.667 ENot applicable
746853Winds -unspecified2003-12-01 00:11:477.7 S, 11.667 ENot applicable
746865Winds -unspecified2004-01-01 00:15:207.7 S, 11.667 ENot applicable
749863Currents -subsurface Eulerian2004-01-11 16:00:007.7 S, 11.65 ENot applicable
746877Winds -unspecified2004-02-01 00:13:267.7 S, 11.667 ENot applicable
746889Winds -unspecified2004-03-01 00:21:007.7 S, 11.667 ENot applicable
746890Winds -unspecified2004-04-01 00:01:357.7 S, 11.667 ENot applicable
746908Winds -unspecified2004-05-01 00:56:437.7 S, 11.667 ENot applicable
746921Winds -unspecified2004-06-01 00:09:487.7 S, 11.667 ENot applicable
746933Winds -unspecified2004-07-01 00:21:527.7 S, 11.667 ENot applicable
1095338CTD or STD cast2009-08-02 08:38:007.66825 S, 11.71846 ENot applicable
1095351CTD or STD cast2009-08-02 10:07:007.62991 S, 11.6955 ENot applicable