Metadata Report for BODC Series Reference Number 1137632


Metadata Summary

Data Description

Data Category CTD or STD cast
Instrument Type
NameCategories
Sea-Bird SBE 911 CTD  CTD; water temperature sensor; salinity sensor
Tritech PA-200 Altimeter  altimeters
WET Labs {Sea-Bird WETLabs} ECO BB(RT)D backscattering sensor  optical backscatter sensors
Chelsea Technologies Group Aquatracka III fluorometer  fluorometers
Chelsea Technologies Group Alphatracka II transmissometer  transmissometers
Instrument Mounting research vessel
Originating Country United Kingdom
Originator Dr Brian King
Originating Organization National Oceanography Centre, Southampton
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) GO-SHIP
 

Data Identifiers

Originator's Identifier CTD_DI368_014_2DB
BODC Series Reference 1137632
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 2011-07-25 06:43
End Time (yyyy-mm-dd hh:mm) -
Nominal Cycle Interval 2.0 decibars
 

Spatial Co-ordinates

Latitude 36.84360 N ( 36° 50.6' N )
Longitude 20.00140 W ( 20° 0.1' W )
Positional Uncertainty 0.0 to 0.01 n.miles
Minimum Sensor or Sampling Depth 2.98 m
Maximum Sensor or Sampling Depth 4555.2 m
Minimum Sensor or Sampling Height 10.11 m
Maximum Sensor or Sampling Height 4562.33 m
Sea Floor Depth 4565.31 m
Sea Floor Depth Source DATAHEAD
Sensor or Sampling Distribution Variable common depth - All sensors are grouped effectively at the same depth, but this depth varies significantly during the series
Sensor or Sampling Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
Sea Floor Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
 

Parameters

BODC CODERankUnitsTitle
ACYCAA011DimensionlessSequence number
AHSFZZ011MetresHeight (spatial coordinate) relative to bed surface in the water body
BB117R011per metre per nanometre per steradianAttenuation due to backscatter (660 nm wavelength at 117 degree incidence) by the water body [particulate >unknown phase] by in-situ optical backscatter measurement
CNCLCCI11Siemens per metreElectrical conductivity of the water body by in-situ conductivity cell and calibration against independent measurements
CPHLPM011Milligrams per cubic metreConcentration of chlorophyll-a {chl-a CAS 479-61-8} per unit volume of the water body [particulate >unknown phase] by in-situ chlorophyll fluorometer and manufacturer's calibration applied
DEPHPR011MetresDepth (spatial coordinate) relative to water surface in the water body by profiling pressure sensor and conversion to seawater depth using UNESCO algorithm
DOXYSC011Micromoles per litreConcentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase] by Sea-Bird SBE 43 sensor and calibration against sample data
OXYSZZ011PercentSaturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase]
POPTDR011PercentTransmittance (red light wavelength) per 25cm of the water body by 25cm path length red light transmissometer
POTMCV011Degrees CelsiusPotential temperature of the water body by computation using UNESCO 1983 algorithm
PRESPR011DecibarsPressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level
PSALST011DimensionlessPractical salinity of the water body by CTD and computation using UNESCO 1983 algorithm
SIGTPR011Kilograms per cubic metreSigma-theta of the water body by CTD and computation from salinity and potential temperature using UNESCO algorithm
TEMPST011Degrees CelsiusTemperature of the water body by CTD or STD
TOKGPR011Litres per kilogramConversion factor (volume to mass) for the water body by CTD and computation of density (in-situ potential temperature surface pressure) reciprocal from pressure, temperature and salinity

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

The transmissometer data has values exceeding 100% for each cast. This could be indicative of a problem in the calibration of the instrument.

The backscatter attenuation data has negative values within the series and much of the data appears to be below the sensitivity of the instrument. This could be indicative of a problem with the sensor or in the calibration of the instrument.


Data Access Policy

Public domain data

These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.

The recommended acknowledgment is

"This study uses data from the data source/organisation/programme, provided by the British Oceanographic Data Centre and funded by the funding body."


Narrative Documents

Instrument Description

CTD Unit and Auxillary Sensors

A Sea-Bird 9plus CTD system (serial number 09P-46253-0869) used on cruise D368. This was mounted on a 24-way stainless steel rosette frame, equipped with 24 10-litre Niskin bottles. The CTD was fitted with the following scientific sensors:

Sensor Serial Number Last calibration date Comments
Digiquartz Pressure 100898 31st July 2009 -
Primary Temperature SBE-3P 3P-4116 17th December 2010 -
Secondary Temperature SBE-3P 3P-4782 17th December 2010 -
Primary Conductivity SBE-4C 04C-2580 17th December 2010 -
Secondary Conductivity SBE-4C 04C-2841 17th December 2010 -
Tritech PA200 Altimeter 6196.118171 14th November 2006 -
Sea-Bird SBE 43 dissolved oxygen sensor 43-1940 16th September 2010 -
Chelsea Aquatracka MkIII fluorometer 088-2050-095 21st April 2011 -
Chelsea MkII Alphatracka Transmissometer (25cm path) 07-6075-001 5th October 2010 -
TRDI WHM300kHz LADCP 13329 - -
WETLabs BBRTD Light Scatter Sensor BBRTD-169 14th April 2010 -

Sea-Bird Electronics SBE 911 and SBE 917 series CTD profilers

The SBE 911 and SBE 917 series of conductivity-temperature-depth (CTD) units are used to collect hydrographic profiles, including temperature, conductivity and pressure as standard. Each profiler consists of an underwater unit and deck unit or SEARAM. Auxiliary sensors, such as fluorometers, dissolved oxygen sensors and transmissometers, and carousel water samplers are commonly added to the underwater unit.

Underwater unit

The CTD underwater unit (SBE 9 or SBE 9 plus) comprises a protective cage (usually with a carousel water sampler), including a main pressure housing containing power supplies, acquisition electronics, telemetry circuitry, and a suite of modular sensors. The original SBE 9 incorporated Sea-Bird's standard modular SBE 3 temperature sensor and SBE 4 conductivity sensor, and a Paroscientific Digiquartz pressure sensor. The conductivity cell was connected to a pump-fed plastic tubing circuit that could include auxiliary sensors. Each SBE 9 unit was custom built to individual specification. The SBE 9 was replaced in 1997 by an off-the-shelf version, termed the SBE 9 plus, that incorporated the SBE 3 plus (or SBE 3P) temperature sensor, SBE 4C conductivity sensor and a Paroscientific Digiquartz pressure sensor. Sensors could be connected to a pump-fed plastic tubing circuit or stand-alone.

Temperature, conductivity and pressure sensors

The conductivity, temperature, and pressure sensors supplied with Sea-Bird CTD systems have outputs in the form of variable frequencies, which are measured using high-speed parallel counters. The resulting count totals are converted to numeric representations of the original frequencies, which bear a direct relationship to temperature, conductivity or pressure. Sampling frequencies for these sensors are typically set at 24 Hz.

The temperature sensing element is a glass-coated thermistor bead, pressure-protected inside a stainless steel tube, while the conductivity sensing element is a cylindrical, flow-through, borosilicate glass cell with three internal platinum electrodes. Thermistor resistance or conductivity cell resistance, respectively, is the controlling element in an optimized Wien Bridge oscillator circuit, which produces a frequency output that can be converted to a temperature or conductivity reading. These sensors are available with depth ratings of 6800 m (aluminium housing) or 10500 m (titanium housing). The Paroscientific Digiquartz pressure sensor comprises a quartz crystal resonator that responds to pressure-induced stress, and temperature is measured for thermal compensation of the calculated pressure.

Additional sensors

Optional sensors for dissolved oxygen, pH, light transmission, fluorescence and others do not require the very high levels of resolution needed in the primary CTD channels, nor do these sensors generally offer variable frequency outputs. Accordingly, signals from the auxiliary sensors are acquired using a conventional voltage-input multiplexed A/D converter (optional). Some Sea-Bird CTDs use a strain gauge pressure sensor (Senso-Metrics) in which case their pressure output data is in the same form as that from the auxiliary sensors as described above.

Deck unit or SEARAM

Each underwater unit is connected to a power supply and data logging system: the SBE 11 (or SBE 11 plus) deck unit allows real-time interfacing between the deck and the underwater unit via a conductive wire, while the submersible SBE 17 (or SBE 17 plus) SEARAM plugs directly into the underwater unit and data are downloaded on recovery of the CTD. The combination of SBE 9 and SBE 17 or SBE 11 are termed SBE 917 or SBE 911, respectively, while the combinations of SBE 9 plus and SBE 17 plus or SBE 11 plus are termed SBE 917 plus or SBE 911 plus.

Specifications

Specifications for the SBE 9 plus underwater unit are listed below:

Parameter Range Initial accuracy Resolution at 24 Hz Response time
Temperature -5 to 35°C 0.001°C 0.0002°C 0.065 sec
Conductivity 0 to 7 S m-1 0.0003 S m-1 0.00004 S m-1 0.065 sec (pumped)
Pressure 0 to full scale (1400, 2000, 4200, 6800 or 10500 m) 0.015% of full scale 0.001% of full scale 0.015 sec

Further details can be found in the manufacturer's specification sheet.

Chelsea Technologies Group Aquatracka MKIII fluorometer

The Chelsea Technologies Group Aquatracka MKIII is a logarithmic response fluorometer. Filters are available to enable the instrument to measure chlorophyll, rhodamine, fluorescein and turbidity.

It uses a pulsed (5.5 Hz) xenon light source discharging along two signal paths to eliminate variations in the flashlamp intensity. The reference path measures the intensity of the light source whilst the signal path measures the intensity of the light emitted from the specimen under test. The reference signal and the emitted light signals are then applied to a ratiometric circuit. In this circuit, the ratio of returned signal to reference signal is computed and scaled logarithmically to achieve a wide dynamic range. The logarithmic conversion accuracy is maintained at better than one percent of the reading over the full output range of the instrument.

Two variants of the instrument are available, both manufactured in titanium, capable of operating in depths from shallow water down to 2000 m and 6000 m respectively. The optical characteristics of the instrument in its different detection modes are visible below:

Excitation Chlorophyll a Rhodamine Fluorescein Turbidity
Wavelength (nm) 430 500 485 440*
Bandwidth (nm) 105 70 22 80*
Emission Chlorophyll a Rhodamine Fluorescein Turbidity
Wavelength (nm) 685 590 530 440*
Bandwidth (nm) 30 45 30 80*

* The wavelengths for the turbidity filters are customer selectable but must be in the range 400 to 700 nm. The same wavelength is used in the excitation path and the emission path.

The instrument measures chlorophyll a, rhodamine and fluorescein with a concentration range of 0.01 µg l-1 to 100 µg l-1. The concentration range for turbidity is 0.01 to 100 FTU (other wavelengths are available on request).

The instrument accuracy is ± 0.02 µg l-1 (or ± 3% of the reading, whichever is greater) for chlorophyll a, rhodamine and fluorescein. The accuracy for turbidity, over a 0 - 10 FTU range, is ± 0.02 FTU (or ± 3% of the reading, whichever is greater).

Further details are available from the Aquatracka MKIII specification sheet.

Chelsea Technologies Group ALPHAtracka and ALPHAtracka II transmissometers

The Chelsea Technologies Group ALPHAtracka (the Mark I) and its successor, the ALPHAtracka II (the Mark II), are both accurate (< 0.3 % fullscale) transmissometers that measure the beam attenuation coefficient at 660 nm. Green (565 nm), yellow (590 nm) and blue (470 nm) wavelength variants are available on special order.

The instrument consists of a Transmitter/Reference Assembly and a Detector Assembly aligned and spaced apart by an open support frame. The housing and frame are both manufactured in titanium and are pressure rated to 6000 m depth.

The Transmitter/Reference housing is sealed by an end cap. Inside the housing an LED light source emits a collimated beam through a sealed window. The Detector housing is also sealed by an end cap. A signal photodiode is placed behind a sealed window to receive the collimated beam from the Transmitter.

The primary difference between the ALPHAtracka and ALPHAtracka II is that the Alphatracka II is implemented with surface-mount technology; this has enabled a much smaller diameter pressure housing to be used while retaining exactly the same optical train as in the Mark I. Data from the Mark II version are thus fully compatible with that already obtained with the Mark I. The performance of the Mark II is further enhanced by two electronic developments from Chelsea Technologies Group - firstly, all items are locked in a signal nulling loop of near infinite gain and, secondly, the signal output linearity is inherently defined by digital circuitry only.

Among other advantages noted above, these features ensure that the optical intensity of the Mark II, indicated by the output voltage, is accurately represented by a straight line interpolation between a reading near full-scale under known conditions and a zero reading when blanked off.

For optimum measurements in a wide range of environmental conditions, the Mark I and Mark II are available in 5 cm, 10 cm and 25 cm path length versions. Output is default factory set to 2.5 volts but can be adjusted to 5 volts on request.

Further details about the Mark II instrument are available from the Chelsea Technologies Group ALPHAtrackaII specification sheet.

WETLabs Single-angle Backscattering Meter ECO BB

An optical scattering sensor that measures scattering at 117°. This angle was determined as a minimum convergence point for variations in the volume scattering function induced by suspended materials and water. The measured signal is less determined by the type and size of the materials in the water and is more directly correlated to their concentration.

Several versions are available, with minor differences in their specifications:

  • ECO BB(RT)provides analog or RS-232 serial output with 4000 count range
  • ECO BB(RT)D adds the possibility of being deployed in depths up to 6000 m while keeping the capabilities of ECO BB(RT)
  • ECO BB provides the capabilities of ECO BB(RT) with periodic sampling
  • ECO BBB is similar to ECO BB but with internal batteries for autonomous operation
  • ECO BBS is similar to ECO BB but with an integrated anti-fouling bio-wiper
  • ECO BBSB has the capabilities of ECO BBS but with internal batteries for autonomous operation

Specifications

Wavelength 471, 532, 660 nm
Sensitivity (m-1 sr-1)

1.2 x 10-5 at 470 nm

7.7 x 10-6 at 532 nm

3.8 x 10-6 at 660 nm

Typical range ~0.0024 to 5 m-1
Linearity 99% R2
Sample rate up to 8Hz
Temperature range 0 to 30°C
Depth rating

600 m (standard)

6000 m (deep)

Further details can be found in the manufacturer's specification sheet.

Tritech Digital Precision Altimeter PA200

This altimeter is a sonar ranging device that gives the height above the sea bed when mounted vertically. When mounted in any other attitude the sensor provides a subsea distance. It can be configured to operate on its own or under control from an external unit and can be supplied with simultaneous analogue and digital outputs, allowing them to interface to PC devices, data loggers, telemetry systems and multiplexers.

These instruments can be supplied with different housings, stainless steel, plastic and aluminum, which will limit the depth rating. There are three models available: the PA200-20S, PA200-10L and the PA500-6S, whose transducer options differ slightly.

Specifications

Transducer options PA200-20S P200-10L PA500-6S
Frequency (kHz) 200 200 500
Beamwidth (°) 20 Conical 10 included conical beam 6 Conical
Operating range

1 to 100 m

0.7 to 50 m

-

0.3 to 50 m

0.1 to 10 m

Common specifications are presented below

Digital resolution 1 mm
Analogue resolution 0.25% of range
Depth rating 700 , 2000, 4000 and 6800 m
Operating temperature -10 to 40°C

Further details can be found in the manufacturer's specification sheet.

BODC Processing

The CTD data were supplied to BODC in 29 MStar files and converted to the BODC internal format (QXF).

During transfer the originator's variables were mapped to unique BODC parameter codes. The following table shows the parameter mapping.

Originator's variable Units Description BODC Code Units Comments
scan - Scan number - - Not transferred - will be superseded in BODC processing
time - Time - - Not transferred - will be superseded in BODC processing
press decibars Pressure (spatial co-ordinate) exerted by the water body by profiling pressure sensor and corrected to read zero at sea level. PRESPR01 decibars -
pressure_temp degC - - - Not transferred - not an environmental variable
temp degC Temperature of the water body by CTD TEMPST01 degC -
temp1 degC Temperature of the water body by CTD - - Secondary channel, not retained
temp2 degC Temperature of the water body by CTD - - Secondary channel, not retained
cond mS/cm Electrical conductivity of the water body by in-situ conductivity cell and calibration against independent measurements CNCLCCI1 Siemens per metre cond divided by 10
cond1 mS/cm Electrical conductivity of the water body by CTD - - Secondary channel, not retained
cond2 mS/cm Electrical conductivity of the water body by CTD - - Secondary channel, not retained
altimeter m Height above bed in the water body AHSFZZ01 m -
oxygen umol/l Concentration of oxygen {O2} per unit volume of the water body [dissolved phase] by Sea-Bird SBE 43 sensor and calibration against sample data DOXYSC01 Micromoles per litre -
fluor ug/l Concentration of chlorophyll-a {chl-a} per unit volume of the water body [particulate phase] by in-situ chlorophyll fluorometer and manufacturer's calibration applied CPHLPM01 mg/m3 ug/l=mg/m3
trans % Transmittance (red light wavelength) per 25cm of the water body by 25cm path length red light transmissometer POPTDR01 % -
turbidity per metre per nanometre per steradian Attenuance due to backscatter (660 nm wavelength at 117 degree incidence) by the water body [particulate phase] by in-situ optical backscatter measurement BB117R01 per metre per nanometre per steradian -
psal pss-78 Practical salinity of the water body by CTD and computation using UNESCO 1983 algorithm PSALST01 pss-78 -
psal1 pss-78 Practical salinity of the water body by CTD - - Secondary channel, not retained
psal2 pss-78 Practical salinity of the water body by CTD and computation using UNESCO 1983 algorithm and calibration against independent measurements - - Secondary channel, not retained
depth m Depth below surface (sampling event start) of the water body by profiling pressure sensor and conversion to depth using unspecified algorithm. DEPHPR01 m -
potemp degC Potential Temperature - - Not transferred - can be calculated from pressure, salinity and temperature
potemp1 degC Potential Temperature - - Not transferred - can be calculated from pressure, salinity and temperature
potemp2 degC Potential Temperature - - Not transferred - can be calculated from pressure, salinity and temperature

Following transfer the data were screened using BODC in-house visualisation software. Suspect data values were assigned the appropriate BODC data quality flag. Missing data values, where present, were changed to the missing data value and assigned a BODC data quality flag

Originator's Data Processing

Sampling strategy

A Stainless Steel framed Conductivity-Temperature-Depth (CTD) unit was used on D368 to produce vertical profiles of the temperature and salinity of the water column. In total 29 CTD profiles were conducted during D368.

Data Acquisition and Initial Processing

The data were processed using MStar routines. Further details on the processing can be found in the cruise report.

The processed data, together with the raw Sea-Bird, configuration and bottle files, were supplied to BODC for banking.


Project Information

The Global Ocean Ship-based Hydrographic Investigations Program (GO-SHIP) project document

The Global Ocean Ship-based Hydrographic Investigations Program (GO-SHIP) brings together scientists with interests in physical oceanography, the carbon cycle, marine biogeochemistry and ecosystems, and other users and collectors of ocean interior data to develop a sustained global network of hydrographic sections as part of the Global Ocean / Climate Observing System.

The GO-SHIP Panel was established in 2007 by the IOCCP and CLIVAR to develop a strategy for a sustained global repeat hydrography program as a contribution to the OceanObs09 Conference (September 2009) and to revise the 1994 WOCE hydrographic program manual. Based on community discussions at the OceanObs09 Conference, the Panel recommended the development of a sustained repeat hydrography program to:

  • develop formal international agreements for a sustained international repeat ship-based hydrography program, including an internationally-agreed strategy and implementation plan building on the guidelines in the Community White Paper,
  • advocate for national contributions to this strategy and participation in the global program,
  • provide a central forum for communication and coordination, and
  • develop syntheses of hydrographic data, in partnership with national, regional, and global research programs.

The IOCCP and CLIVAR International Project Offices have agreed to provide project office support to this program as it develops.

Project office support for GO-SHIP is provided by the IOC-SCOR International Ocean Carbon Coordination Project (IOCCP) and the Climate Variability and Predictability Project (CLIVAR). Major financial support for this project is provided by the U.S. National Science Foundation through a grant to UNESCO - IOC (OCE - 0715161) and a grant to the Scientific Committee on Oceanic Research (OCE - 0608600) for the IOCCP.

For more information please see the official project website at GO-SHIP


Data Activity or Cruise Information

Cruise

Cruise Name D368
Departure Date 2011-07-15
Arrival Date 2011-08-04
Principal Scientist(s)Brian A King (National Oceanography Centre, Southampton)
Ship RRS Discovery

Complete Cruise Metadata Report is available here


Fixed Station Information

Fixed Station Information

Station NameWOCE Station A16N
CategoryOffshore route/traverse

World Ocean Circulation Experiment (WOCE) Hydrographic Programme Section A16N

WOCE established a hydrographic section in the Atlantic, from Reykjavik, Iceland to Natal, Brazil, designated A16N. The station geographic boundaries are: 63° 17.58'N to 6° 0.64'S, 29° 00.00'W to 19° 59.99'W

BODC image

History of Occupations at Section A16N

Cruise Date begins Date ends Country PSO
R/V OCEANUS 202 23-07-1988 01-09-1988 USA M. McCartney
R/V Ronald H. Brown A16N_2003A 04-06-2003 11-08-2003 USA J. Bullister
RRS Discovery D368 15-07-2011 04-08-2011 United Kingdom B. King
R/V Ronald H. Brown 13-04-2013 A16N 16-07-2013 25-09-2013 USA M. Baringer / J. Bullister

Related Fixed Station activities are detailed in Appendix 1


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification

Appendix 1: WOCE Station A16N

Related series for this Fixed Station are presented in the table below. Further information can be found by following the appropriate links.

If you are interested in these series, please be aware we offer a multiple file download service. Should your credentials be insufficient for automatic download, the service also offers a referral to our Enquiries Officer who may be able to negotiate access.

Series IdentifierData CategoryStart date/timeStart positionCruise
1851701Water sample data2011-07-20 05:39:0049.0055 N, 19.9956 WRRS Discovery D368
1137503CTD or STD cast2011-07-20 05:39:5849.0055 N, 19.9956 WRRS Discovery D368
1851713Water sample data2011-07-20 20:49:0048.0253 N, 19.9941 WRRS Discovery D368
1137515CTD or STD cast2011-07-20 20:49:1648.0253 N, 19.9941 WRRS Discovery D368
1851725Water sample data2011-07-21 07:13:0047.0003 N, 19.9879 WRRS Discovery D368
1137527CTD or STD cast2011-07-21 07:13:5947.0003 N, 19.9879 WRRS Discovery D368
1851737Water sample data2011-07-21 16:52:0045.9897 N, 20.0014 WRRS Discovery D368
1137539CTD or STD cast2011-07-21 16:52:2945.9897 N, 20.0014 WRRS Discovery D368
1851749Water sample data2011-07-22 02:25:0045.0024 N, 20.0067 WRRS Discovery D368
1137540CTD or STD cast2011-07-22 02:25:1645.0024 N, 20.0067 WRRS Discovery D368
1137552CTD or STD cast2011-07-22 12:45:3644.0091 N, 20.0155 WRRS Discovery D368
1851750Water sample data2011-07-22 14:36:0044.0091 N, 20.0155 WRRS Discovery D368
1851762Water sample data2011-07-22 20:30:0043.003 N, 19.9911 WRRS Discovery D368
1137564CTD or STD cast2011-07-22 20:30:1443.003 N, 19.9911 WRRS Discovery D368
1851774Water sample data2011-07-23 06:02:0042.0475 N, 20.0009 WRRS Discovery D368
1137576CTD or STD cast2011-07-23 06:02:2342.0475 N, 20.0009 WRRS Discovery D368
1851786Water sample data2011-07-23 14:59:0041.0009 N, 20.0086 WRRS Discovery D368
1137588CTD or STD cast2011-07-23 14:59:3741.0009 N, 20.0086 WRRS Discovery D368
1851798Water sample data2011-07-24 00:20:0039.9944 N, 19.9832 WRRS Discovery D368
1137607CTD or STD cast2011-07-24 00:20:0639.9944 N, 19.9832 WRRS Discovery D368
1851805Water sample data2011-07-24 09:34:0038.998 N, 20.007 WRRS Discovery D368
1137619CTD or STD cast2011-07-24 09:34:1738.998 N, 20.007 WRRS Discovery D368
1851817Water sample data2011-07-24 19:02:0038.0117 N, 20.0023 WRRS Discovery D368
1137620CTD or STD cast2011-07-24 19:02:0938.0117 N, 20.0023 WRRS Discovery D368
1851829Water sample data2011-07-25 06:43:0036.8436 N, 20.0014 WRRS Discovery D368
1851830Water sample data2011-07-25 16:00:0036.0092 N, 20.0106 WRRS Discovery D368
1137644CTD or STD cast2011-07-25 16:00:5036.0092 N, 20.0106 WRRS Discovery D368
1851842Water sample data2011-07-26 02:36:0035.003 N, 20.5454 WRRS Discovery D368
1137656CTD or STD cast2011-07-26 02:36:4735.003 N, 20.5454 WRRS Discovery D368
1851854Water sample data2011-07-26 13:07:0033.9991 N, 21.1263 WRRS Discovery D368
1137668CTD or STD cast2011-07-26 13:07:2933.9991 N, 21.1263 WRRS Discovery D368
1851866Water sample data2011-07-26 23:56:0033.01 N, 21.692 WRRS Discovery D368
1137681CTD or STD cast2011-07-26 23:56:5633.01 N, 21.692 WRRS Discovery D368
1851878Water sample data2011-07-27 10:44:0031.9972 N, 22.2491 WRRS Discovery D368
1137693CTD or STD cast2011-07-27 10:44:4031.9972 N, 22.2491 WRRS Discovery D368
1851891Water sample data2011-07-27 20:45:0031.0079 N, 22.8011 WRRS Discovery D368
1137700CTD or STD cast2011-07-27 20:45:0931.0079 N, 22.8011 WRRS Discovery D368
1851909Water sample data2011-07-28 07:19:0030.004 N, 23.3775 WRRS Discovery D368
1137712CTD or STD cast2011-07-28 07:19:1730.004 N, 23.3775 WRRS Discovery D368
1851910Water sample data2011-07-28 17:42:0028.9979 N, 23.9312 WRRS Discovery D368
1137724CTD or STD cast2011-07-28 17:42:2328.9979 N, 23.9312 WRRS Discovery D368
1851922Water sample data2011-07-29 08:38:0028.018 N, 24.507 WRRS Discovery D368
1137736CTD or STD cast2011-07-29 08:38:2128.018 N, 24.507 WRRS Discovery D368
1851934Water sample data2011-07-29 19:18:0026.9996 N, 25.0612 WRRS Discovery D368
1137748CTD or STD cast2011-07-29 19:18:3926.9996 N, 25.0612 WRRS Discovery D368
1851946Water sample data2011-07-30 06:10:0026.0015 N, 25.6236 WRRS Discovery D368
1137761CTD or STD cast2011-07-30 06:10:3226.0015 N, 25.6236 WRRS Discovery D368
1851958Water sample data2011-07-30 16:08:0024.9945 N, 26.1913 WRRS Discovery D368
1137773CTD or STD cast2011-07-30 16:08:5924.9945 N, 26.1913 WRRS Discovery D368
1851971Water sample data2011-07-31 02:22:0024.0008 N, 26.7593 WRRS Discovery D368
1137785CTD or STD cast2011-07-31 02:22:2124.0008 N, 26.7593 WRRS Discovery D368
1851983Water sample data2011-07-31 10:51:0023.3423 N, 27.1358 WRRS Discovery D368
1137797CTD or STD cast2011-07-31 10:51:4623.3423 N, 27.1358 WRRS Discovery D368