Search the data

Metadata Report for BODC Series Reference Number 1215729


Metadata Summary

Data Description

Data Category CTD or STD cast
Instrument Type
NameCategories
Sea-Bird SBE 43 Dissolved Oxygen Sensor  dissolved gas sensors
Sea-Bird SBE 911plus CTD  CTD; water temperature sensor; salinity sensor
Sea-Bird SBE 3plus (SBE 3P) temperature sensor  water temperature sensor
Sea-Bird SBE 4C conductivity sensor  salinity sensor
Paroscientific Digiquartz depth sensors  water pressure sensors
Instrument Mounting lowered unmanned submersible
Originating Country United Kingdom
Originator Mr George Slesser
Originating Organization Marine Scotland Aberdeen Marine Laboratory
Processing Status banked
Online delivery of data Download available - Ocean Data View (ODV) format
Project(s) -
 

Data Identifiers

Originator's Identifier SC13/13/397
BODC Series Reference 1215729
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 2013-10-06 15:42
End Time (yyyy-mm-dd hh:mm) -
Nominal Cycle Interval 1.0 decibars
 

Spatial Co-ordinates

Latitude 60.76467 N ( 60° 45.9' N )
Longitude 6.36583 W ( 6° 21.9' W )
Positional Uncertainty 0.0 to 0.01 n.miles
Minimum Sensor or Sampling Depth 4.95 m
Maximum Sensor or Sampling Depth 176.24 m
Minimum Sensor or Sampling Height 8.75 m
Maximum Sensor or Sampling Height 180.05 m
Sea Floor Depth 185.0 m
Sea Floor Depth Source DATAHEAD
Sensor or Sampling Distribution Variable common depth - All sensors are grouped effectively at the same depth, but this depth varies significantly during the series
Sensor or Sampling Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
Sea Floor Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
 

Parameters

BODC CODERankUnitsTitle
ACYCAA011DimensionlessSequence number
CNDCST011Siemens per metreElectrical conductivity of the water body by CTD
CPHLPS011Milligrams per cubic metreConcentration of chlorophyll-a {chl-a CAS 479-61-8} per unit volume of the water body [particulate >unknown phase] by in-situ chlorophyll fluorometer and calibration against sample data
DOXYZZXX1Micromoles per litreConcentration of oxygen {O2 CAS 7782-44-7} per unit volume of the water body [dissolved plus reactive particulate phase]
OXYSSU011PercentSaturation of oxygen {O2 CAS 7782-44-7} in the water body [dissolved plus reactive particulate phase] by Sea-Bird SBE 43 sensor and computation from concentration using Benson and Krause algorithm
POTMCV011Degrees CelsiusPotential temperature of the water body by computation using UNESCO 1983 algorithm
PRESPR011DecibarsPressure (spatial coordinate) exerted by the water body by profiling pressure sensor and correction to read zero at sea level
PSALST011DimensionlessPractical salinity of the water body by CTD and computation using UNESCO 1983 algorithm
SIGTPR011Kilograms per cubic metreSigma-theta of the water body by CTD and computation from salinity and potential temperature using UNESCO algorithm
TEMPST011Degrees CelsiusTemperature of the water body by CTD or STD
TURBPR011Nephelometric Turbidity UnitsTurbidity of water in the water body by in-situ optical backscatter measurement and laboratory calibration against formazin

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database


Data Access Policy

Public domain data

These data have no specific confidentiality restrictions for users. However, users must acknowledge data sources as it is not ethical to publish data without proper attribution. Any publication or other output resulting from usage of the data should include an acknowledgment.

The recommended acknowledgment is

"This study uses data from the data source/organisation/programme, provided by the British Oceanographic Data Centre and funded by the funding body."


Narrative Documents

Sea-Bird Dissolved Oxygen Sensor SBE 43 and SBE 43F

The SBE 43 is a dissolved oxygen sensor designed for marine applications. It incorporates a high-performance Clark polarographic membrane with a pump that continuously plumbs water through it, preventing algal growth and the development of anoxic conditions when the sensor is taking measurements.

Two configurations are available: SBE 43 produces a voltage output and can be incorporated with any Sea-Bird CTD that accepts input from a 0-5 volt auxiliary sensor, while the SBE 43F produces a frequency output and can be integrated with an SBE 52-MP (Moored Profiler CTD) or used for OEM applications. The specifications below are common to both.

Specifications

Housing Plastic or titanium
Membrane

0.5 mil- fast response, typical for profile applications

1 mil- slower response, typical for moored applications

Depth rating

600 m (plastic) or 7000 m (titanium)

10500 m titanium housing available on request

Measurement range 120% of surface saturation
Initial accuracy 2% of saturation
Typical stability 0.5% per 1000 h

Further details can be found in the manufacturer's specification sheet.

FRV Scotia 0213S, 0313S, 0513S, 0813S, 0913S, 1113S, 1313S, 1513S, 1613S, and 1713S CTD Instrument Description

Sampling Strategy

CTD casts were carried out during the on FRV Scotia cruises 0213S, 0313S, 0513S, 0813S, 0913S, 1113S, 1313S, 1513S, 1613S, and 1713S using the instrumentation detailed below.

FRV Scotia Cruise CTD Unit and auxiliary sensors Model Serial # Calibration Date (YYYY-MM-DD)
0213S, 0313S Pressure Sea-Bird SBE 19plus V2 SEACAT CTD 6028 2011-12-23
Temperature (primary sensor)
Conductivity (primary sensor)
Fluorometer and scatter sensor WET Labs ECO FLNTU 0942 2012-02-23
0813S, 0913S, 1113S Pressure Sea-Bird SBE 19plus V2 SEACAT CTD 6029 2012-09-26
Temperature (primary sensor)
Conductivity (primary sensor)
Fluorometer and scatter sensor WET Labs ECO FLNTU 0947 2008-03-05
1513S, 1613S Pressure Sea-Bird SBE 19plus V2 SEACAT CTD 6028 2013-08-07
Temperature (primary sensor)
Conductivity (primary sensor)
Fluorometer and scatter sensor WET Labs ECO FLNTU 0942 2012-02-23
0513S, 1313S, 1713S Pressure Paroscientific Digiquartz depth sensor 64240 2010-08-05
Temperature (Primary sensor) Sea-Bird SBE 911plus CTD/ Sea-Bird SBE 3plus (SBE 3P) temperature sensor 2041 2012-07-17
Temperature (Secondary sensor) Sea-Bird SBE 911plus CTD/ Sea-Bird SBE 3plus (SBE 3P) temperature sensor 2015 2012-07-17
Conductivity (Primary sensor) Sea-Bird SBE 911plus CTD/ Sea-Bird SBE 4C conductivity sensor 1615 2012-07-20
Conductivity (Secondary sensor) Sea-Bird SBE 911plus CTD/ Sea-Bird SBE 4C conductivity sensor 1669 2012-07-20
Fluorometer and scatter sensor WET Labs ECO FLNTU 2542 2012-01-20
Oxygen Sea-Bird SBE 43 Dissolved Oxygen Sensor 0504 2012-07-07

No changes to the CTD instrumentation were recorded during these cruises.

Sea-Bird Electronics SBE 911 and SBE 917 series CTD profilers

The SBE 911 and SBE 917 series of conductivity-temperature-depth (CTD) units are used to collect hydrographic profiles, including temperature, conductivity and pressure as standard. Each profiler consists of an underwater unit and deck unit or SEARAM. Auxiliary sensors, such as fluorometers, dissolved oxygen sensors and transmissometers, and carousel water samplers are commonly added to the underwater unit.

Underwater unit

The CTD underwater unit (SBE 9 or SBE 9 plus) comprises a protective cage (usually with a carousel water sampler), including a main pressure housing containing power supplies, acquisition electronics, telemetry circuitry, and a suite of modular sensors. The original SBE 9 incorporated Sea-Bird's standard modular SBE 3 temperature sensor and SBE 4 conductivity sensor, and a Paroscientific Digiquartz pressure sensor. The conductivity cell was connected to a pump-fed plastic tubing circuit that could include auxiliary sensors. Each SBE 9 unit was custom built to individual specification. The SBE 9 was replaced in 1997 by an off-the-shelf version, termed the SBE 9 plus, that incorporated the SBE 3 plus (or SBE 3P) temperature sensor, SBE 4C conductivity sensor and a Paroscientific Digiquartz pressure sensor. Sensors could be connected to a pump-fed plastic tubing circuit or stand-alone.

Temperature, conductivity and pressure sensors

The conductivity, temperature, and pressure sensors supplied with Sea-Bird CTD systems have outputs in the form of variable frequencies, which are measured using high-speed parallel counters. The resulting count totals are converted to numeric representations of the original frequencies, which bear a direct relationship to temperature, conductivity or pressure. Sampling frequencies for these sensors are typically set at 24 Hz.

The temperature sensing element is a glass-coated thermistor bead, pressure-protected inside a stainless steel tube, while the conductivity sensing element is a cylindrical, flow-through, borosilicate glass cell with three internal platinum electrodes. Thermistor resistance or conductivity cell resistance, respectively, is the controlling element in an optimized Wien Bridge oscillator circuit, which produces a frequency output that can be converted to a temperature or conductivity reading. These sensors are available with depth ratings of 6800 m (aluminium housing) or 10500 m (titanium housing). The Paroscientific Digiquartz pressure sensor comprises a quartz crystal resonator that responds to pressure-induced stress, and temperature is measured for thermal compensation of the calculated pressure.

Additional sensors

Optional sensors for dissolved oxygen, pH, light transmission, fluorescence and others do not require the very high levels of resolution needed in the primary CTD channels, nor do these sensors generally offer variable frequency outputs. Accordingly, signals from the auxiliary sensors are acquired using a conventional voltage-input multiplexed A/D converter (optional). Some Sea-Bird CTDs use a strain gauge pressure sensor (Senso-Metrics) in which case their pressure output data is in the same form as that from the auxiliary sensors as described above.

Deck unit or SEARAM

Each underwater unit is connected to a power supply and data logging system: the SBE 11 (or SBE 11 plus) deck unit allows real-time interfacing between the deck and the underwater unit via a conductive wire, while the submersible SBE 17 (or SBE 17 plus) SEARAM plugs directly into the underwater unit and data are downloaded on recovery of the CTD. The combination of SBE 9 and SBE 17 or SBE 11 are termed SBE 917 or SBE 911, respectively, while the combinations of SBE 9 plus and SBE 17 plus or SBE 11 plus are termed SBE 917 plus or SBE 911 plus.

Specifications

Specifications for the SBE 9 plus underwater unit are listed below:

Parameter Range Initial accuracy Resolution at 24 Hz Response time
Temperature -5 to 35°C 0.001°C 0.0002°C 0.065 sec
Conductivity 0 to 7 S m-1 0.0003 S m-1 0.00004 S m-1 0.065 sec (pumped)
Pressure 0 to full scale (1400, 2000, 4200, 6800 or 10500 m) 0.015% of full scale 0.001% of full scale 0.015 sec

Further details can be found in the manufacturer's specification sheet.

Processing by BODC of FRV Scotia cruises 0213S, 0313S, 0513S, 0813S, 0913S, 1113S, 1313S, 1513S, 1613S, and 1713S CTD data.

The data arrived at BODC in 10 concatenated ASCII format files. Each file represented one of FRV Scotia cruises 0213S (56 casts), 0313S (59 casts), 0513S (102 casts), 0813S (40 casts), 0913S (84 casts), 1113S (15 casts), 1313S (62 casts), 1513S (2 casts), 1613S (25 casts), and 1713S (37 casts).

The concatenated files were sub-divided into individual files for each cast using BODC in house Matlab software, and then reformatted to the internal BODC format.

The following table shows how the variables within the files were mapped to appropriate BODC parameter codes:

Originator's Variable Units Description BODC Parameter Code Units Comment
Pressure dbar Pressure (spatial co-ordinate) exerted by the water body by profiling pressure sensor and corrected to read zero at sea level PRESPR01 dbar -
Temperature (edit) Centigrade Temperature of the water body by CTD or STD TEMPST01 °C Celsius = Centigrade so no unit conversion required.
Conductivity (edit) mS cm-1 Electrical conductivity of the water body by CTD CNDCST01 S m-1 Conversion of Originators units to BODC units: conductivity(edit)/10. BODC applied Originator calibration during transfer.
Fluorescence* µg l-1 Concentration of chlorophyll-a {chl-a} per unit volume of the water body [particulate phase] by in-situ chlorophyll fluorometer. CPHLPR01 mg m-3 No field calibrations supplied by the Originator. This applies to all flourescence data from cruises 0213S, 0313S, 0813S, 0913S, 1113S, 1513S, and 1613S.
Fluorescence* µg l-1 Concentration of chlorophyll-a {chl-a} per unit volume of the water body [particulate phase] by in-situ chlorophyll fluorometer. CPHLPS01 mg m-3 Field samples for calibration were taken during the cruise but not applied by the Originator. BODC has applied this calibration. This applies to all flourescence data from cruises 0513S, 1313S, and 1713S.
Turbidity NTU Turbidity of the water body by in-situ optical backscatter measurement and laboratory calibration against formazin TURBPR01 NTU No turbidity data were submitted for cruise FRV Scotia 0512S.
Oxygen (ml l-1) ml l-1 Concentration of oxygen (O2) per unit volume of the water body (dissolved phase) DOXYZZXX µmol l-1 Conversion of Originators units to BODC units: oxygen (ml l-1) * 44.661. BODC applied Originator calibration during transfer.
- - Saturation of oxygen (O2) in the water body [dissolved plus reactive particulate phase] by Sea-Bird SBE 43 sensor and computation from concentration using Benson and Krause algorithm OXYSSU01 % Derived from PSALST01, TEMPST01 and DOXYZZXX in transfer using Benson and Krause algorithm (1984).
- - Practical salinity of the water body by CTD and computation using UNESCO 1983 algorithm PSALST01 Dimensionless Derived from TEMPST01 and CNDCST01 in transfer using Fofonoff and Millard (1983).
- - Sigma-theta of the water body by CTD and computation from salinity and potential temperature using UNESCO algorithm SIGTPR01 kg m-3 Derived from PSALST01, TEMPST01 and PRESPR01 in transfer using Fofonoff and Millard (1983).
Temperature (pri) Centigrade Unadjusted temperature data - - Primary Temperature. Data were not loaded by BODC as Originator stated Temperature (edit) channel was a quality controlled version of the primary channel.
Conductivity (pri) mS cm-1 Unadjusted conductivity data - - Primary Conductivity. Data were not loaded by BODC as Originator stated Conductivity (edit) channel was a quality controlled version of the primary channel.
Temperature (sec) Centigrade Unadjusted temperature data - - Secondary Temperature. Data were not loaded by BODC where supplied as Originator stated Temperature (edit) channel was a quality controlled version of the primary channel.
Conductivity (sec) mS cm-1 Unadjusted conductivity data - - Secondary Conductivity. Data were not loaded by BODC where supplied as Originator stated Conductivity (edit) channel was a quality controlled version of the primary channel.
Oxygen % saturation cm3 dm-3 - - - Oxygen saturation data supplied by Originator were derived using unknown methodology. No further processing was carried out.

* Originators variable name is Fluorescence but BODC have identified that the data have had manufacturer's calibrations applied and are therefore chlorophyll values.

The reformatted data were visualised using the in-house EDSERPLO software. Suspect data were marked by adding an appropriate quality control flag, missing data by both setting the data to an appropriate value and setting the quality control flag.

Reference

Fofonoff, P., Millard Jr, R.C., 1983. Algorithms for computation of fundamental properties of seawater.Unesco Technical Papers in Marine Sciences 44, 53 pp.

Processing by Originator of FRV Scotia 1313S CTD data

Sampling Strategy

Marine Scotland performed 62 CTD casts during cruise FRV Scotia 1313S as part of ongoing research funded by the Scottish Government.

The ship set sail on 2 October 2013, journeying from Aberdeen to carry out CTD deployments on the JONSIS long term monitoring section, the Nolso_Flugga section, the Fair Isle- Munken section and the Cape Wrath - Faroe section, all located in the North Sea and North East Atlantic Ocean. The ship returned to dock in Aberdeen on 16 October 2013.

A SBE32 carousal was used to collect all water samples taken during the cruise.

Data Processing

The CTD data were processed by Marine Scotland using the Sea-Bird SeaSoft routines as recommended in the SeaSoft manual for model type Sea-Bird SBE19plus V2 SEACAT.

Pressure data were binned to 1 dbar using SeaSoft and the primary temperature and conductivity channels were adjusted to produce 'edit' channels. Marine Scotland regards the 'edit' channels as the definitive version of the data.

The adjustments consisted of a de-spiking process using Marine Scotland in-house visualisation software and, as necessary, application of a low pass filter as described in Sy (1985). The time was recorded in UTC.

Field Calibrations

Conductivity

Marine Scotland used 85 water samples collected by SBE32 carousal to generate a calibration equation as follows:

calibrated conductivity (mS cm-1) = measured conductivity x 0.999948 + 0.002485

The calibration was not applied to the data by the Originator.

Fluorescence

Marine Scotland used 78 water samples collected by the SBE35 carousel to generate a calibration equation as follows:

Calibrated fluorescence (µg l-1) = measured fluorescence x 0.00058 + 0.089722.

The calibration was not applied to the data by the Originator.

Reference

Sy A., 1985. An alternative editing technique for oceanographic data. Deep Sea Research, 32 (12), 1591-1599,


Project Information


No Project Information held for the Series

Data Activity or Cruise Information

Cruise

Cruise Name 1313S
Departure Date 2013-10-02
Arrival Date 2013-10-16
Principal Scientist(s)George Slesser (Marine Scotland Aberdeen Marine Laboratory)
Ship FRV Scotia

Complete Cruise Metadata Report is available here


Fixed Station Information

Fixed Station Information

Station NameFaroe-Cape Wrath Transect
CategoryOffshore route/traverse

Faroe-Cape Wrath Transect

The Faroe-Cape Wrath transect was started for the THOR (Thermohaline Overturning - at Risk?) project (2007-2013) and has now continued under NACLIM (North Atlantic Climate Variability) project (2012-2017), both projects ran under European Union (EU) Seventh Framework Programme (FP7).

Marine Scotland first sampled the transect in May 2009. Marine Scotland hope to sample this line twice a year (April-May and September-October) and if possible in December.

The stations along this line will be mainly used for CTD deployments although salinity samples will be taken along the line for calibration purposes. Some nutrient samples have been taken by Marine Scotland but it is not anticipated that nutrient sampling will become a regular occurrence.

The Faroese are also sampling this line.

Map of standard stations

BODC image

Line Stations

Listed below are details of the standard hydrographic stations that form the Faroe-Cape Wrath line.

Station Name Latitude Longitude Depth (m) Spacing (nm)
FWZ-19 59° 30.00' N 06° 10.00' W 152 -
FWZ-18 59° 34.82' N 06° 10.00' W 196 4.81
FWZ-17 59° 39.64' N 06° 10.00' W 220 4.81
FWZ-16 59° 44.45' N 06° 10.00' W 277 4.80
FWZ-15 59° 49.27' N 06° 10.00' W 457 4.81
FWZ-14 59° 54.09' N 06° 10.00' W 600 4.81
FWZ-13 59° 58.91' N 06° 10.00' W 970 4.81
FWZ-12 60° 03.73' N 06° 10.00' W 1082 4.81
FWZ-11 60° 08.54' N 06° 10.00' W 1195 4.80
FWZ-10 60° 12.76' N 06° 10.00' W 1212 4.21
FWZ-09 60° 18.18' N 06° 10.00' W 616 5.41
FWZ-08 60° 23.00' N 06° 10.00' W 423 4.81
FWZ-07 60° 30.63'N 06° 13.88'W 302 7.86
FWZ-06 60° 38.26'N 06° 17.77'W 275 7.86
FWZ-05 60° 45.89'N 06° 21.69'W 184 7.86
FWZ-04 60° 53.52'N 06° 25.65'W 138 7.86
FWZ-03 61° 01.14'N 06° 29.63'W 142 7.85
FWZ-02 61° 08.76'N 06° 33.65'W 125 7.85
FWZ-01 61° 16.38' N 06° 37.70' W 100 7.86
- - - Totals 107.12

Faroe - Cape Wrath (extended line)

This line is not shown on the map but may be sampled occasionally.

Station Name Latitude Longitude Depth (m) Spacing (nm)
FWZ-29 58° 36.60' N 06° 13.09' W 112 -
FWZ-28 58° 42.06' N 06° 12.18' W 116 5.5
FWZ-27 58° 47.42' N 06° 11.72' W 116 5.4
FWZ-26 58° 52.75' N 06° 11.71' W 113 5.4
FWZ-25 58° 58.02' N 06° 13.41' W 74 5.3
FWZ-24 59° 03.36' N 06° 14.34' W 63 5.4
FWZ-23 59° 08.61' N 06° 14.18' W 106 5.3
FWZ-22 59° 13.84' N 06° 12.02' W 113 5.3
FWZ-21 59° 19.21' N 06° 11.39' W 148 5.4
FWZ-20 59° 24.58' N 06° 10.58' W 155 5.4
- - - Totals 48.4

CTD sampling history

Cruise FRV Scotia 0512S, between 07 May 2012 - 22 May 2012, sampled stations FWZ-01 to FWZ-19 inclusively.

Related Fixed Station activities are detailed in Appendix 1


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain
B nominal value
Q value below limit of quantification

Appendix 1: Faroe-Cape Wrath Transect

Related series for this Fixed Station are presented in the table below. Further information can be found by following the appropriate links.

If you are interested in these series, please be aware we offer a multiple file download service. Should your credentials be insufficient for automatic download, the service also offers a referral to our Enquiries Officer who may be able to negotiate access.

Series IdentifierData CategoryStart date/timeStart positionCruise
1034577CTD or STD cast2009-05-21 03:38:0059.36033 N, 5.43383 WFRV Scotia 0709S
1034589CTD or STD cast2009-05-21 05:08:0059.53183 N, 5.59 WFRV Scotia 0709S
1034590CTD or STD cast2009-05-21 06:26:0059.6775 N, 5.63067 WFRV Scotia 0709S
1034608CTD or STD cast2009-05-21 07:43:0059.77233 N, 5.71533 WFRV Scotia 0709S
1034621CTD or STD cast2009-05-21 09:03:0059.86933 N, 5.7385 WFRV Scotia 0709S
1034633CTD or STD cast2009-05-21 10:47:0059.9645 N, 5.80433 WFRV Scotia 0709S
1034645CTD or STD cast2009-05-21 12:48:0060.08433 N, 5.87983 WFRV Scotia 0709S
1034657CTD or STD cast2009-05-21 14:57:0060.21917 N, 5.95467 WFRV Scotia 0709S
1034669CTD or STD cast2009-05-21 16:51:0060.3085 N, 6.004 WFRV Scotia 0709S
1034670CTD or STD cast2009-05-21 18:21:0060.3985 N, 6.062 WFRV Scotia 0709S
1034682CTD or STD cast2009-05-21 20:22:0060.617 N, 6.2 WFRV Scotia 0709S
1034694CTD or STD cast2009-05-21 22:38:0060.89083 N, 6.3625 WFRV Scotia 0709S
1034701CTD or STD cast2009-05-22 00:28:0061.14117 N, 6.51317 WFRV Scotia 0709S
1180181CTD or STD cast2012-05-10 16:10:0059.49933 N, 6.1675 WFRV Scotia 0512S
1180193CTD or STD cast2012-05-10 17:19:0059.58033 N, 6.167 WFRV Scotia 0512S
1180200CTD or STD cast2012-05-10 18:19:0059.65933 N, 6.1695 WFRV Scotia 0512S
1180212CTD or STD cast2012-05-10 19:17:0059.73967 N, 6.17 WFRV Scotia 0512S
1180224CTD or STD cast2012-05-11 13:13:0059.82117 N, 6.16583 WFRV Scotia 0512S
1180236CTD or STD cast2012-05-11 14:41:0059.90167 N, 6.16717 WFRV Scotia 0512S
1180248CTD or STD cast2012-05-11 16:29:0059.9815 N, 6.16633 WFRV Scotia 0512S
1180261CTD or STD cast2012-05-11 18:32:0060.06183 N, 6.16417 WFRV Scotia 0512S
1180273CTD or STD cast2012-05-11 20:19:0060.143 N, 6.16483 WFRV Scotia 0512S
1180285CTD or STD cast2012-05-11 22:18:0060.21333 N, 6.16783 WFRV Scotia 0512S
1180297CTD or STD cast2012-05-12 00:23:0060.306 N, 6.17067 WFRV Scotia 0512S
1180304CTD or STD cast2012-05-12 01:53:0060.38583 N, 6.16867 WFRV Scotia 0512S
1180316CTD or STD cast2012-05-12 03:27:0060.50883 N, 6.2315 WFRV Scotia 0512S
1180328CTD or STD cast2012-05-12 04:59:0060.638 N, 6.297 WFRV Scotia 0512S
1180341CTD or STD cast2012-05-12 06:20:0060.76467 N, 6.3645 WFRV Scotia 0512S
1180353CTD or STD cast2012-05-12 07:31:0060.89267 N, 6.43133 WFRV Scotia 0512S
1180365CTD or STD cast2012-05-12 08:41:0061.01917 N, 6.49683 WFRV Scotia 0512S
1180377CTD or STD cast2012-05-12 09:47:0061.14667 N, 6.563 WFRV Scotia 0512S
1180389CTD or STD cast2012-05-12 10:53:0061.274 N, 6.62633 WFRV Scotia 0512S
1213194CTD or STD cast2013-05-15 21:10:0061.2705 N, 6.63383 WFRV Scotia 0513S
1213201CTD or STD cast2013-05-15 22:15:0061.14933 N, 6.56283 WFRV Scotia 0513S
1213213CTD or STD cast2013-05-15 23:27:0061.02017 N, 6.4845 WFRV Scotia 0513S
1213225CTD or STD cast2013-05-16 00:35:0060.89533 N, 6.42333 WFRV Scotia 0513S
1213237CTD or STD cast2013-05-16 01:36:0060.76533 N, 6.35933 WFRV Scotia 0513S
1213249CTD or STD cast2013-05-16 02:38:0060.6385 N, 6.294 WFRV Scotia 0513S
1213250CTD or STD cast2013-05-16 03:52:0060.50983 N, 6.2315 WFRV Scotia 0513S
1213262CTD or STD cast2013-05-16 05:10:0060.38267 N, 6.16683 WFRV Scotia 0513S
1213274CTD or STD cast2013-05-16 06:23:0060.30317 N, 6.16933 WFRV Scotia 0513S
1213286CTD or STD cast2013-05-16 07:45:0060.20817 N, 6.15933 WFRV Scotia 0513S
1213298CTD or STD cast2013-05-16 09:39:0060.14317 N, 6.16233 WFRV Scotia 0513S
1213305CTD or STD cast2013-05-16 11:30:0060.06383 N, 6.1615 WFRV Scotia 0513S
1213317CTD or STD cast2013-05-16 13:15:0059.9805 N, 6.16417 WFRV Scotia 0513S
1213329CTD or STD cast2013-05-16 14:50:0059.90283 N, 6.16417 WFRV Scotia 0513S
1213330CTD or STD cast2013-05-16 16:13:0059.82083 N, 6.16617 WFRV Scotia 0513S
1213342CTD or STD cast2013-05-16 17:21:0059.73867 N, 6.1635 WFRV Scotia 0513S
1213354CTD or STD cast2013-05-16 18:17:0059.66017 N, 6.16767 WFRV Scotia 0513S
1213366CTD or STD cast2013-05-16 19:13:0059.56883 N, 6.16083 WFRV Scotia 0513S
1213378CTD or STD cast2013-05-16 19:57:0059.50167 N, 6.16717 WFRV Scotia 0513S
1215582CTD or STD cast2013-10-05 12:58:0059.501 N, 6.16917 WFRV Scotia 1313S
1215594CTD or STD cast2013-10-05 13:53:0059.58017 N, 6.16533 WFRV Scotia 1313S
1215601CTD or STD cast2013-10-05 14:48:0059.65917 N, 6.16817 WFRV Scotia 1313S
1215613CTD or STD cast2013-10-05 15:53:0059.74167 N, 6.1675 WFRV Scotia 1313S
1215625CTD or STD cast2013-10-05 17:11:0059.81983 N, 6.162 WFRV Scotia 1313S
1215637CTD or STD cast2013-10-05 18:25:0059.90267 N, 6.16117 WFRV Scotia 1313S
1215649CTD or STD cast2013-10-05 19:50:0059.9845 N, 6.14833 WFRV Scotia 1313S
1215650CTD or STD cast2013-10-06 05:07:0060.06233 N, 6.16667 WFRV Scotia 1313S
1215662CTD or STD cast2013-10-06 06:43:0060.14217 N, 6.1655 WFRV Scotia 1313S
1215674CTD or STD cast2013-10-06 08:20:0060.21283 N, 6.167 WFRV Scotia 1313S
1215686CTD or STD cast2013-10-06 09:56:0060.30317 N, 6.167 WFRV Scotia 1313S
1215698CTD or STD cast2013-10-06 11:12:0060.38267 N, 6.166 WFRV Scotia 1313S
1215705CTD or STD cast2013-10-06 12:49:0060.5105 N, 6.22933 WFRV Scotia 1313S
1215717CTD or STD cast2013-10-06 14:15:0060.63767 N, 6.29583 WFRV Scotia 1313S
1215730CTD or STD cast2013-10-06 17:15:0060.8925 N, 6.43083 WFRV Scotia 1313S
1215742CTD or STD cast2013-10-06 17:51:0060.892 N, 6.428 WFRV Scotia 1313S
1215754CTD or STD cast2013-10-06 19:41:0061.01933 N, 6.49333 WFRV Scotia 1313S
1215766CTD or STD cast2013-10-06 20:52:0061.146 N, 6.5585 WFRV Scotia 1313S
1215778CTD or STD cast2013-10-06 22:12:0061.2715 N, 6.6225 WFRV Scotia 1313S