Metadata Report for BODC Series Reference Number 314268


Metadata Summary

Data Description

Data Category CTD or STD cast
Instrument Type
NameCategories
Bissett-Bermann 9006 STD system  CTD; water temperature sensor; salinity sensor
Instrument Mounting research vessel
Originating Country United Kingdom
Originator -
Originating Organization Scottish Marine Biological Association (now Scottish Association for Marine Science)
Processing Status banked
Project(s) -
 

Data Identifiers

Originator's Identifier CH375/QX
BODC Series Reference 314268
 

Time Co-ordinates(UT)

Start Time (yyyy-mm-dd hh:mm) 1975-03-11 15:21
End Time (yyyy-mm-dd hh:mm) -
Nominal Cycle Interval -
 

Spatial Co-ordinates

Latitude 57.38330 N ( 57° 23.0' N )
Longitude 13.75000 W ( 13° 45.0' W )
Positional Uncertainty Unspecified
Minimum Sensor Depth 7.83 m
Maximum Sensor Depth 145.89 m
Minimum Sensor Height -
Maximum Sensor Height -
Sea Floor Depth -
Sensor Distribution Variable common depth - All sensors are grouped effectively at the same depth, but this depth varies significantly during the series
Sensor Depth Datum Instantaneous - Depth measured below water line or instantaneous water body surface
Sea Floor Depth Datum -
 

Parameters

BODC CODE Rank Units Short Title Title
PRESPR01 1 Decibars Pres_Z Pressure (spatial co-ordinate) exerted by the water body by profiling pressure sensor and corrected to read zero at sea level
SSALPR01 1 Parts per thousand UspSal Salinity of the water body by conductivity cell
TEMPST01 1 Degrees Celsius WC_temp_CTD Temperature of the water body by CTD or STD
 

Definition of Rank

  • Rank 1 is a one-dimensional parameter
  • Rank 2 is a two-dimensional parameter
  • Rank 0 is a one-dimensional parameter describing the second dimension of a two-dimensional parameter (e.g. bin depths for moored ADCP data)

Problem Reports

No Problem Report Found in the Database


Data Access Policy

Open Data supplied by Natural Environment Research Council (NERC)

You must always use the following attribution statement to acknowledge the source of the information: "Contains data supplied by Natural Environment Research Council."


Narrative Documents

Bissett-Berman 9060 Salinity Temperature and Depth

The B-B 9060 STD measured salinity, temperature and depth and whose analogue output was in graphical form. The plots created were of salinity and temperature versus depth which had to be manually digitised.

RRS Challenger Cruise 3/75 CTD Data Documentation

Introduction

Documentation for the CTD data collected on RRS Challenger 3/75 (March 1975) by the Scottish Marine Biological Association, Oban, Argyll, Scotland, UK, under the direction of D. J. Ellett.

Instrumentation

The instrument used was a Bissett Berman 9040 CTD system and the data were logged on a Hewlett Packard 9820 and stored in an integer format. Instrument lowering and raising speeds were between 0.5m/s and 1m/s. An acoustic pinger was placed above the CTD to give an accurate depth measurement, this could then be used to check the CTD pressure calibration. An NIO bottle with reversing thermometers was placed above the pinger, within 2m of the CTD system. A bottle sample was taken at the bottom of the cast providing the temperature and salinity are uniform at that point. If large temperature or salinity gradients were present then the bottle sample was triggered at a suitable site on the upcast. A surface salinity sample was also taken at the start of the dip.

Calibrations and Data Quality

The CTD was not calibrated in the laboratory. The manufacturer's calibration was used and water samples taken to check the calibration and apply corrections where necessary.

Temperature

The manufacturer's calibration was used to convert the raw data to to physical units using the equation below:

Temperature (deg C) = (10**6/Pt -2238.68/55.84)
where Pt is the temperature period in microseconds

These values were then plotted against the water bottle (i.e. reversing thermometer) temperatures and a regression line fitted to the data such that:

Temperature(WB) = m x Temperature(CTD) + c

Then the regression coefficients (m and c) were applied to correct the CTD temperature data - these are given in the table below.

Conductivity

The manufacturer's calibration was used to convert the raw data to to physical units using the equation below:

Conductivity (mmho/cm) = (10**6/Pc - 4995)/58.12 + 10
where Pc is the conductivity period in microseconds

The water bottle salinities and corrected CTD temperatures were used to calculate the water bottle conductivity values. These values were then plotted against the CTD conductivities and a regression line fitted to the data such that:

Conductivity(WB) = m x Conductivity(CTD) + c

Then the regression coefficients were applied to correct the CTD conductivity data - these are given in the table below.

Pressure

The depths from the acoustic pinger were noted where the bottle samples were taken and then used to check the calibration of the pressure sensor - unless calibration values were available from the reversing thermometers. The equation below was used to convert the pressure period to physical units.

Pressure = (10**6/Pd - 9712)/0.26267
where Pd is the pressure period in microseconds

A regression fit was carried out using the calibration values and the slope and intercept determined. The pressure values could then be corrected using:

Pressure (CORR) = m x Pressure(CTD) + c

The fit of the CTD data to the water bottle calibration data is given in the table below:

Variable Slope (m) Intercept (c) Standard Deviation
Temperature (°C) 1.0004 0.0540 0.003
Salinity (ppt) 0.8931 3.8041 0.023
Pressure (dbar) 0.5048 -7.2163 7.045

Data Processing

Obvious wild points were edited out of the calibration file and the calibration programs run to obtain values for the slopes and intercepts for temperature, pressure and conductivity. These were then applied to the uncalibrated data. Conductivities were converted to conductivity ratios and then converted to salinities using UNESCO recommended routines and sigma-t was calculated. The data values were then sieved to ensure a minimum separation between pressure values of 1 dbar. The data were then visually inspected and major spikes flagged.

Reference

Fofonoff, N.P. and Millard Jr., R.C. (1983).
Algorithms for the computation of fundamental properties of sea water. UNESCO Technical Paper on Marine Science 44.


Project Information


No Project Information held for the Series

Data Activity or Cruise Information

Cruise

Cruise Name CH3/75
Departure Date 1975-03-04
Arrival Date 1975-03-13
Principal Scientist(s)David J Ellett (Scottish Marine Biological Association)
Ship RRS Challenger

Complete Cruise Metadata Report is available here


Fixed Station Information

Fixed Station Information

Station NameDML Malin Head Line
CategoryOffshore route/traverse

DML Malin Head Line

The DML Malin Head Line is a survey section crossing the Rockall Trough, west of Scotland. The section starts close to the outcrop of Rockall and heads in a south easterly direction towards Malin Head (County Donegal, Republic of Ireland). The final station is at the shelf edge. The section comprises 15 fixed STD/CTD stations, which were established as part of routine monitoring work west of Scotland by Dunstaffnage Marine Laboratory (DML). The DML Malin Head Line was occupied between the mid 1970s and mid 1990s.

Map of standard DML Malin Head Line STD/CTD Stations

BODC image

Map produced using the GEBCO Digital Atlas.

The white triangles indicate the nominal positions of each standard Malin Head Line Station. The black circle indicates the location of Rockall.

Nominal station details

DML Malin Head Line Stations

Station Nominal latitude Nominal longitude Approx.
depth (m)
Comment
CS 55° 47.0' N 09° 16.0' W 160  
DS 55° 52.0' N 09° 27.0' W 1000  
ES 55° 56.0' N 09° 38.0' W 1550  
FS 56° 00.0' N 09° 50.0' W 2050  
GS 56° 07.0' N 10° 12.0' W 2134  
HS 56° 15.0' N 10° 33.0' W 2230  
IS 56° 26.0' N 11° 03.0' W 2608  
JS 56° 37.0' N 11° 33.0' W 2550  
KS 56° 47.0' N 12° 03.0' W 2320  
LS 56° 58.0' N 12° 33.0' W 2024  
MS 57° 06.0' N 12° 56.0' W 1600  
NS 57° 10.0' N 13° 07.0' W 1000  
OS 57° 13.0' N 13° 15.0' W 250  
PS 57° 18.0' N 13° 30.0' W 200  
QS 57° 23.0' N 13° 45.0' W 155  

Other Series linked to this Fixed Station for this cruise - 314207 314220 314232 314244 314256

Other Cruises linked to this Fixed Station (with the number of series) - CH10A/75 (9) CH112 (1) CH114 (3) CH12A/75 (7) CH75B (5) CH81 (13) CH97 (1) LF1/89 (5) LF2/89 (1)

Fixed Station Information

Station NameDML Malin Head Line - Station QS
CategoryOffshore location
Latitude57° 23.00' N
Longitude13° 45.00' W
Water depth below MSL155.0 m

DML Station QS

Station QS is one of 15 fixed STD/CTD stations crossing the Rockall Trough between the outcrop of Rockall and the shelf edge to the south east. The station was established by scientists at Dunstaffnage Marine Laboratory (DML).

Other Cruises linked to this Fixed Station (with the number of series) - CH10A/75 (1) CH81 (1)


BODC Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
Blank Unqualified
< Below detection limit
> In excess of quoted value
A Taxonomic flag for affinis (aff.)
B Beginning of CTD Down/Up Cast
C Taxonomic flag for confer (cf.)
D Thermometric depth
E End of CTD Down/Up Cast
G Non-taxonomic biological characteristic uncertainty
H Extrapolated value
I Taxonomic flag for single species (sp.)
K Improbable value - unknown quality control source
L Improbable value - originator's quality control
M Improbable value - BODC quality control
N Null value
O Improbable value - user quality control
P Trace/calm
Q Indeterminate
R Replacement value
S Estimated value
T Interpolated value
U Uncalibrated
W Control value
X Excessive difference

SeaDataNet Quality Control Flags

The following single character qualifying flags may be associated with one or more individual parameters with a data cycle:

Flag Description
0 no quality control
1 good value
2 probably good value
3 probably bad value
4 bad value
5 changed value
6 value below detection
7 value in excess
8 interpolated value
9 missing value
A value phenomenon uncertain